Re: Installing NanoVna-Saver : First Time Problems/Fixes

paul larner
 

seems to me the vna saver is iffy,i get a smith chart with only the trace displayed ie none of the circle markings,its like the trace is in thin air,any ideas?,on my lappy the creed display just jitters all over,mentioned this a few times but lagley seems to be ignorred!


Re: Brand new user here

paul larner
 

only half an answer as per i see!!,why do ppl bother if only answering half the original question?,beggars belife so many folks on forums do this or go off on a tangent!!,just my thoughts! 73 m3vuv


connector swap

paul larner
 

hi all im thinking of changing from sma to bnc connectors on my vna,maybe mounted on an extender board hooked up to the vna with some small coax,is there any issues with doing this as regards acuracy etc,i assume using 50 ohm coax and re calibrating it should be ok?,any idea?.,cheers M3vuv.


Re: New version of NanoVNA-Saver: 0.2.1

 

Hi Larry,

Thanks for the tip Softmaker freeoffice. It has a full visual basic compatibilty with free version? Zplots not work on older excel, libre office and openoffice. Currently write reply from my phone, i will test later.

73,
Lajos


NanoVNA Saver software version 0.2.1 TDR operation

 

I have one more question regarding the NanoVNA Saver software

In the TDR display there are two traces, One Red and one blue. I understand
the red but not the blue. Would some please give me an explanation of the
blue trace?

I appreciate any responses.
*Clyde K. Spencer*


Re: USB cable

 

I have one more question regarding the NanoVNA Saver software

In the TDR display there are two traces, One Red and one blue. I understand
the red but not the blue. Would some please give me an explanation of the
blue trace?

I appreciate any responses.

*Clyde K. Spencer*



On Sat, Dec 7, 2019 at 11:37 PM Clyde Spencer via Groups.Io <cftr01b=
[email protected]> wrote:

Good evening all,

I have the VNA Saver 0.2.1 software. I like the features and the operation
is somewhat intuitive. I do have a couple questions.
1. Is there a newer version of the VNA Saver software?
2. Reading the user manual posted here It references using the "REAL" mode
when looking at the TDR function. I seem to not be able to find that. I
would really like to get thisworking
3. I am not sure of my NanoVNA firmware but I think it is QRP 0.4.3. Is
there newer firmware?

I appreciate all that respond,

Clyde KD8AN


*Clyde K. Spencer*



On Fri, Dec 6, 2019 at 5:44 AM Gyula Molnar <gyula.ha3hz@...> wrote:

Hi Larry,
I'm glad that many people have noticed what the original author wrote in
the "Know issues" section of the NanoVNA alpha1 kit assembly manual.
I think the same way, thank you for trying to confirm that I'm not trying
in vain.

73, Gyula
On Fri, Dec 6, 2019 at 12:14 AM, Larry Rothman wrote:

Good to know, Bob.
I had suggested to the devs to use 2 LiPo s with a linear 5v Reg to run
the
unit in order to reduce RFI from that charger/inverter chip.
Banggood has a 2S charging board for about $2 that you run off of an 8
to 12v
source. I'm going to look at that setup soon in addition to modding
the
bridge and freq source circuits per the discussion on Hugen's GitHub
repo.
CheersLarry






Re: USB cable

 

Good evening all,

I have the VNA Saver 0.2.1 software. I like the features and the operation
is somewhat intuitive. I do have a couple questions.
1. Is there a newer version of the VNA Saver software?
2. Reading the user manual posted here It references using the "REAL" mode
when looking at the TDR function. I seem to not be able to find that. I
would really like to get thisworking
3. I am not sure of my NanoVNA firmware but I think it is QRP 0.4.3. Is
there newer firmware?

I appreciate all that respond,

Clyde KD8AN


*Clyde K. Spencer*

On Fri, Dec 6, 2019 at 5:44 AM Gyula Molnar <gyula.ha3hz@...> wrote:

Hi Larry,
I'm glad that many people have noticed what the original author wrote in
the "Know issues" section of the NanoVNA alpha1 kit assembly manual.
I think the same way, thank you for trying to confirm that I'm not trying
in vain.

73, Gyula
On Fri, Dec 6, 2019 at 12:14 AM, Larry Rothman wrote:

Good to know, Bob.
I had suggested to the devs to use 2 LiPo s with a linear 5v Reg to run
the
unit in order to reduce RFI from that charger/inverter chip.
Banggood has a 2S charging board for about $2 that you run off of an 8
to 12v
source. I'm going to look at that setup soon in addition to modding the
bridge and freq source circuits per the discussion on Hugen's GitHub
repo.
CheersLarry




Re: USB cable

 

Sorry Bob but the stlink won't charge the battery as it's connected to the 3v side of the regulator that runs the micro.?



On Sat, 7 Dec 2019 at 10:25 PM, Bob Albert via Groups.Io<bob91343@...> wrote: So I just hold it in place and can charge the battery via the ST-LINK?? I don't care about programming at this point but I would like connectivity to a computer.? Holding it in place is another story.? I already have charging capability so it's just data I need to get.
Bob

On Saturday, December 7, 2019, 02:49:01 AM PST, Gyula Molnar <gyula.ha3hz@...> wrote:

The picture below shows the ST-Link V2 connector to be routed to a pin row. When you use it with one of your fingers, you gently press it when you are programming. No need to solder.
This was the first time I needed this and it worked right away.
The RST cable is not needed here.

73, Gyula HA3HZ


Re: Brand new user here

Bob Albert
 

Don't move the marker by touching it.? Use, instead, the multipurpose rocker control at the top.? Rocking it one way or the other will move the marker in use.? To change markers you go to the menu.

On Saturday, December 7, 2019, 04:53:21 PM PST, Ray, W4BYG <w4byg@...> wrote:

Just received my new NanoVNA and beginning to learn how to use it.? I
have read the "user guide" but it is not much help with my problems:

After I set the menu settings for display, frequency, etc., and start
trying to use it, I am having trouble moving the markers to where I want
them on the trace.

As I go to touch a marker to move it where I want it, the menu comes up
automatically on the right and the marker doesn't move. I close the menu
and try again with the same result.? Repeated attempts will eventually
allow me to move the marker, but it is still problematic.

What am I doing wrong or missing?

Also, is there a setting where I can tell it to boot back up to my last
screen settings, instead of the factory default out to 900 MHz?? This
would allow saving the battery when I have to be make extended changes
to an antenna and not have to reprogram everything again.

Additionally: Is there software for use with a Win 7 or Win 10 PC and
for Android?

Your assistance would be appreciated.
Ray, W4BYG


Re: USB cable

Bob Albert
 

So I just hold it in place and can charge the battery via the ST-LINK?? I don't care about programming at this point but I would like connectivity to a computer.? Holding it in place is another story.? I already have charging capability so it's just data I need to get.
Bob

On Saturday, December 7, 2019, 02:49:01 AM PST, Gyula Molnar <gyula.ha3hz@...> wrote:

The picture below shows the ST-Link V2 connector to be routed to a pin row. When you use it with one of your fingers, you gently press it when you are programming. No need to solder.
This was the first time I needed this and it worked right away.
The RST cable is not needed here.

73, Gyula HA3HZ


Re: Brand new user here

 

Have you used a stylus? Fingers are too large for that little screen.
*Clyde K. Spencer*

On Sat, Dec 7, 2019 at 7:53 PM Ray, W4BYG <w4byg@...> wrote:

Just received my new NanoVNA and beginning to learn how to use it. I
have read the "user guide" but it is not much help with my problems:

After I set the menu settings for display, frequency, etc., and start
trying to use it, I am having trouble moving the markers to where I want
them on the trace.

As I go to touch a marker to move it where I want it, the menu comes up
automatically on the right and the marker doesn't move. I close the menu
and try again with the same result. Repeated attempts will eventually
allow me to move the marker, but it is still problematic.

What am I doing wrong or missing?

Also, is there a setting where I can tell it to boot back up to my last
screen settings, instead of the factory default out to 900 MHz? This
would allow saving the battery when I have to be make extended changes
to an antenna and not have to reprogram everything again.

Additionally: Is there software for use with a Win 7 or Win 10 PC and
for Android?

Your assistance would be appreciated.
Ray, W4BYG




Re: errors of "error" models

 

#81: On the Physical Expression of Two-Port S-Parameters

Hello,

Allow us, please, to announce that in our sow and facupov
we just expressed physically (that is in a way similar to that
of the Measurement of Ratio of Quantities, which were
introduced by others * and are constantly used since then)
the S11, S12*S21, S22 parameters of a two-port network
in terms only of the VNA reflection measurements of
(S, L, O) loads, with Standard Nominal Values (-1, 0, +1)
respectively, and we uploaded our results at:



Sincerely,

gin&pez@arg

*

:81#


Brand new user here

 

Just received my new NanoVNA and beginning to learn how to use it.? I have read the "user guide" but it is not much help with my problems:

After I set the menu settings for display, frequency, etc., and start trying to use it, I am having trouble moving the markers to where I want them on the trace.

As I go to touch a marker to move it where I want it, the menu comes up automatically on the right and the marker doesn't move. I close the menu and try again with the same result.? Repeated attempts will eventually allow me to move the marker, but it is still problematic.

What am I doing wrong or missing?

Also, is there a setting where I can tell it to boot back up to my last screen settings, instead of the factory default out to 900 MHz?? This would allow saving the battery when I have to be make extended changes to an antenna and not have to reprogram everything again.

Additionally: Is there software for use with a Win 7 or Win 10 PC and for Android?

Your assistance would be appreciated.
Ray, W4BYG


Re: Saving colour preferences

 

No problem. We've all been (more than once)



On Sat, 7 Dec 2019 at 5:10 PM, John<jrdale@...> wrote: Larry--sorry this was my sheer stupidity--of course it is remembering your preferences, I was loading an older file before I had applied them, it is just amazing in its flexibility.


Re: New version of NanoVNA-Saver: 0.2.1

 

Hi Rudi
Your screen shots is very hard to view. A dark background would help a lot.
I think the other details is explained in the report you just have received
Kind regards
Kurt

-----Oprindelig meddelelse-----
Fra: [email protected] <[email protected]> P? vegne af reuterr@...
Sendt: 7. december 2019 21:43
Til: [email protected]
Emne: Re: [nanovna-users] New version of NanoVNA-Saver: 0.2.1

Hello Kurt,

here follows the forgotten attachment: nanoVNA-saver_RG174-30cm-open-end_corrected.png

73, Rudi DL5FA


Re: New version of NanoVNA-Saver: 0.2.1

 

Hi Rudi
I have made a report which by examples show you how to do. You have a poor calibration as the trace is outside Smith Chart and you have not impelemted the delay You need to use the latest 0.2.1 NanoVNA-Saver with Offset implemented which has an error as the delay is to enter by a factor of 10.
Regarding difficulties to see the entire NanoVNA-Saver remember to maximize and in my case font size 7 then it is perfect
Kind regards
Kurt


-----Oprindelig meddelelse-----
Fra: [email protected] <[email protected]> P? vegne af reuterr@...
Sendt: 7. december 2019 19:19
Til: [email protected]
Emne: Re: [nanovna-users] New version of NanoVNA-Saver: 0.2.1

On Sat, Dec 7, 2019 at 03:54 PM, Kurt Poulsen wrote:

Regarding the impedance issue i did look at the phase oscillation from
0.5 to 500MHz when I in the ZPLots has subtracted the length where the
Phase approaches a straight line with oscillations. Then I change the
ZO on either side off 50 ohm in steps of 0.1 ohm and for 51.4 ohm the
phase oscillation was minimized. The return loss oscillation is not
changed by changing the Z0 but rather due to port mismatch.
Hello Kurt,

Thank you very much for your quick answer.

I have 3 questions:
1. Where did you subtract the length (20 cm) ?

2. Did you mean that the S11 phase oscillation curve (about sinus) horizontal center line
should be minimised to a straight line and not be bowed?

3. Did you mean with the change of Z0 to connect a resistor of 50 Ohm
at the end of the 22 cm coax cable? And then vary this resistor in 0.1 Ohm steps
to minimise the amplitude of the phase oscillation amplitude?

I mean your file "NanoVNA supplied cable 50K to 500MHz.png" in post 7877 at 2019-12-05 20:10.

In this screen shot there are 2 diagrams with S11 Phase.
When I try to get a similar diagram with a 30 cm RG174 coax cable with open end I get see attached screen shot nanoVNA-saver_RG174-30cm-open-end.png

73, Rudi DL5FA


Re: Saving colour preferences

 

if you're talking about save trace and grid colors on NanoVNA, you can do it with menu CONFIG => SAVE.

But these colors cannot be saved if you're loading different firmware file into NanoVNA.


Re: Saving colour preferences

 

John, could you please explain, what you're talking about?


Re: Saving colour preferences

 

Larry--sorry this was my sheer stupidity--of course it is remembering your preferences, I was loading an older file before I had applied them, it is just amazing in its flexibility.


Re: New version of NanoVNA-Saver: 0.2.1

 

Hello Kurt,

here follows the forgotten attachment: nanoVNA-saver_RG174-30cm-open-end_corrected.png