Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- Nanovna-Users
- Messages
Search
Re: Installing NanoVna-Saver : First Time Problems/Fixes
paul larner
seems to me the vna saver is iffy,i get a smith chart with only the trace displayed ie none of the circle markings,its like the trace is in thin air,any ideas?,on my lappy the creed display just jitters all over,mentioned this a few times but lagley seems to be ignorred!
|
connector swap
paul larner
hi all im thinking of changing from sma to bnc connectors on my vna,maybe mounted on an extender board hooked up to the vna with some small coax,is there any issues with doing this as regards acuracy etc,i assume using 50 ohm coax and re calibrating it should be ok?,any idea?.,cheers M3vuv.
|
NanoVNA Saver software version 0.2.1 TDR operation
I have one more question regarding the NanoVNA Saver software
In the TDR display there are two traces, One Red and one blue. I understand the red but not the blue. Would some please give me an explanation of the blue trace? I appreciate any responses. *Clyde K. Spencer* |
Re: USB cable
I have one more question regarding the NanoVNA Saver software
In the TDR display there are two traces, One Red and one blue. I understand the red but not the blue. Would some please give me an explanation of the blue trace? I appreciate any responses. *Clyde K. Spencer* On Sat, Dec 7, 2019 at 11:37 PM Clyde Spencer via Groups.Io <cftr01b= [email protected]> wrote: Good evening all, |
Re: USB cable
Good evening all,
toggle quoted message
Show quoted text
I have the VNA Saver 0.2.1 software. I like the features and the operation is somewhat intuitive. I do have a couple questions. 1. Is there a newer version of the VNA Saver software? 2. Reading the user manual posted here It references using the "REAL" mode when looking at the TDR function. I seem to not be able to find that. I would really like to get thisworking 3. I am not sure of my NanoVNA firmware but I think it is QRP 0.4.3. Is there newer firmware? I appreciate all that respond, Clyde KD8AN *Clyde K. Spencer* On Fri, Dec 6, 2019 at 5:44 AM Gyula Molnar <gyula.ha3hz@...> wrote:
Hi Larry, |
Re: USB cable
Sorry Bob but the stlink won't charge the battery as it's connected to the 3v side of the regulator that runs the micro.?
toggle quoted message
Show quoted text
On Sat, 7 Dec 2019 at 10:25 PM, Bob Albert via Groups.Io<bob91343@...> wrote: So I just hold it in place and can charge the battery via the ST-LINK?? I don't care about programming at this point but I would like connectivity to a computer.? Holding it in place is another story.? I already have charging capability so it's just data I need to get. Bob On Saturday, December 7, 2019, 02:49:01 AM PST, Gyula Molnar <gyula.ha3hz@...> wrote:
The picture below shows the ST-Link V2 connector to be routed to a pin row. When you use it with one of your fingers, you gently press it when you are programming. No need to solder. This was the first time I needed this and it worked right away. The RST cable is not needed here. 73, Gyula HA3HZ |
Re: Brand new user here
Bob Albert
Don't move the marker by touching it.? Use, instead, the multipurpose rocker control at the top.? Rocking it one way or the other will move the marker in use.? To change markers you go to the menu.
toggle quoted message
Show quoted text
On Saturday, December 7, 2019, 04:53:21 PM PST, Ray, W4BYG <w4byg@...> wrote:
Just received my new NanoVNA and beginning to learn how to use it.? I have read the "user guide" but it is not much help with my problems: After I set the menu settings for display, frequency, etc., and start trying to use it, I am having trouble moving the markers to where I want them on the trace. As I go to touch a marker to move it where I want it, the menu comes up automatically on the right and the marker doesn't move. I close the menu and try again with the same result.? Repeated attempts will eventually allow me to move the marker, but it is still problematic. What am I doing wrong or missing? Also, is there a setting where I can tell it to boot back up to my last screen settings, instead of the factory default out to 900 MHz?? This would allow saving the battery when I have to be make extended changes to an antenna and not have to reprogram everything again. Additionally: Is there software for use with a Win 7 or Win 10 PC and for Android? Your assistance would be appreciated. Ray, W4BYG |
Re: USB cable
Bob Albert
So I just hold it in place and can charge the battery via the ST-LINK?? I don't care about programming at this point but I would like connectivity to a computer.? Holding it in place is another story.? I already have charging capability so it's just data I need to get.
toggle quoted message
Show quoted text
Bob On Saturday, December 7, 2019, 02:49:01 AM PST, Gyula Molnar <gyula.ha3hz@...> wrote:
The picture below shows the ST-Link V2 connector to be routed to a pin row. When you use it with one of your fingers, you gently press it when you are programming. No need to solder. This was the first time I needed this and it worked right away. The RST cable is not needed here. 73, Gyula HA3HZ |
Re: Brand new user here
Have you used a stylus? Fingers are too large for that little screen.
toggle quoted message
Show quoted text
*Clyde K. Spencer* On Sat, Dec 7, 2019 at 7:53 PM Ray, W4BYG <w4byg@...> wrote:
Just received my new NanoVNA and beginning to learn how to use it. I |
Re: errors of "error" models
#81: On the Physical Expression of Two-Port S-Parameters
Hello, Allow us, please, to announce that in our sow and facupov we just expressed physically (that is in a way similar to that of the Measurement of Ratio of Quantities, which were introduced by others * and are constantly used since then) the S11, S12*S21, S22 parameters of a two-port network in terms only of the VNA reflection measurements of (S, L, O) loads, with Standard Nominal Values (-1, 0, +1) respectively, and we uploaded our results at: Sincerely, gin&pez@arg * :81# |
Brand new user here
Just received my new NanoVNA and beginning to learn how to use it.? I have read the "user guide" but it is not much help with my problems:
After I set the menu settings for display, frequency, etc., and start trying to use it, I am having trouble moving the markers to where I want them on the trace. As I go to touch a marker to move it where I want it, the menu comes up automatically on the right and the marker doesn't move. I close the menu and try again with the same result.? Repeated attempts will eventually allow me to move the marker, but it is still problematic. What am I doing wrong or missing? Also, is there a setting where I can tell it to boot back up to my last screen settings, instead of the factory default out to 900 MHz?? This would allow saving the battery when I have to be make extended changes to an antenna and not have to reprogram everything again. Additionally: Is there software for use with a Win 7 or Win 10 PC and for Android? Your assistance would be appreciated. Ray, W4BYG |
Re: Saving colour preferences
No problem. We've all been (more than once)
On Sat, 7 Dec 2019 at 5:10 PM, John<jrdale@...> wrote: Larry--sorry this was my sheer stupidity--of course it is remembering your preferences, I was loading an older file before I had applied them, it is just amazing in its flexibility. |
Re: New version of NanoVNA-Saver: 0.2.1
Hi Rudi
Your screen shots is very hard to view. A dark background would help a lot. I think the other details is explained in the report you just have received Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af reuterr@... Sendt: 7. december 2019 21:43 Til: [email protected] Emne: Re: [nanovna-users] New version of NanoVNA-Saver: 0.2.1 Hello Kurt, here follows the forgotten attachment: nanoVNA-saver_RG174-30cm-open-end_corrected.png 73, Rudi DL5FA |
Re: New version of NanoVNA-Saver: 0.2.1
Hi Rudi
I have made a report which by examples show you how to do. You have a poor calibration as the trace is outside Smith Chart and you have not impelemted the delay You need to use the latest 0.2.1 NanoVNA-Saver with Offset implemented which has an error as the delay is to enter by a factor of 10. Regarding difficulties to see the entire NanoVNA-Saver remember to maximize and in my case font size 7 then it is perfect Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af reuterr@... Sendt: 7. december 2019 19:19 Til: [email protected] Emne: Re: [nanovna-users] New version of NanoVNA-Saver: 0.2.1 On Sat, Dec 7, 2019 at 03:54 PM, Kurt Poulsen wrote: Hello Kurt, Thank you very much for your quick answer. I have 3 questions: 1. Where did you subtract the length (20 cm) ? 2. Did you mean that the S11 phase oscillation curve (about sinus) horizontal center line should be minimised to a straight line and not be bowed? 3. Did you mean with the change of Z0 to connect a resistor of 50 Ohm at the end of the 22 cm coax cable? And then vary this resistor in 0.1 Ohm steps to minimise the amplitude of the phase oscillation amplitude? I mean your file "NanoVNA supplied cable 50K to 500MHz.png" in post 7877 at 2019-12-05 20:10. In this screen shot there are 2 diagrams with S11 Phase. When I try to get a similar diagram with a 30 cm RG174 coax cable with open end I get see attached screen shot nanoVNA-saver_RG174-30cm-open-end.png 73, Rudi DL5FA |
to navigate to use esc to dismiss