¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Nanovnasaver plots
Hello Roger, Op di 31 mei 2022 om 19:40 schreef Roger Need via groups.io <sailtamarack= [email protected]>: It is not me but
By Victor Reijs · #28248 ·
Re: Locked, then white screen on NanoVNA-H
Roger, It now shows in Device Manager. The screen is still while but I can connect with Nanovna Saver and calibrate using the Calibration Assistant. Do you think it's usable when connected to the
By Perry Westberry · #28247 ·
Re: Which cable measuring method is more accurate - IYHO
The measure feature works well...from the user manual 1.2.5 MEASURE 3. CABLE S11 Choose a frequency range such that the cable length is ~1/4 of the wavelength in the middle of the range. This feature
By Rich NE1EE · #28246 ·
Re: Nanovnasaver plots
I do not own a VNWA so I have no first hand knowledge to share. From what I have read it has better specifications than a NanoVNA. You could join the VNWA group and pose your question there...
By Roger Need · #28245 ·
Re: Nanovnasaver plots
Hi Roger: Thanks for your comments and focus on dispelling the notion that S11 with nanoVNA might be inappropriate for high(er) impedance measuring. Re: ¡°The intent of my post was to reply to
By AG6CX · #28244 ·
Re: Locked, then white screen on NanoVNA-H
Hello, Being a past bata tester of FW for this unit, I have dealt with your problem. The way I cured it is as follows: First shut down the NanoVNA. Remove the back cover. Using small tweezers or what
By Clyde Lambert · #28243 ·
Re: Antenna parameters Re: Nanovnasaver plots
To Roger: Thanks for your comments. Consistent with the physics involved. Ed McCann AG6CX
By AG6CX · #28242 ·
Re: Locked, then white screen on NanoVNA-H
You posted that you cannot see it in Device Manager. Can you see it in DFU mode? This will require opening it and shortening 2 pins. Roger
By Roger Need · #28241 ·
Re: Which cable measuring method is more accurate - IYHO
Example: Cable length measured in M1 point Impedance on M2 More points in this range - better measure quality
By DiSlord · #28240 ·
Re: Which cable measuring method is more accurate - IYHO
Set start frequency more low (cable impedance measured on half frequency from point then smith rotate on 180 degree)
By DiSlord · #28238 ·
Re: NanoVNA-H(4)
Heck, it's confused with NanoVNA-H (4). However, it can be read that it is a 2.8 "-H shipped with this firmware. As Roger Need wrote, the firmware needs to be updated. If you haven't already done so,
By HA3HZ · #28237 ·
Re: Which cable measuring method is more accurate - IYHO
Where did you vind v. 1.2? I can't find that anywhere. Zack W9SZ
By Zack Widup · #28236 ·
Re: NanoVNA-H(4)
Just took another look at your console output. Your firmware is over 2 years old so you need to update if you want to use the NanoVNA app Roger
By Roger Need · #28235 ·
Re: NanoVNA-H(4)
What version of H4 firmware are you using? The NanoVNA app uses a binary protocol to transfer sweep data. This is different than the old ASCII protocol that was initially used by the NanoVNA. If your
By Roger Need · #28234 ·
Re: Nanovnasaver plots
Ed, Yes most antenna analysis is done using the serial R+/-jX form for impedance. However as Jim Lux points out in another post today ( /g/nanovna-users/message/28231 ) there are
By Roger Need · #28233 ·
Re: NanoVNA-H(4)
Does nanoVNA-Saver work on your machine? I can see that win7 sp1 is running. To run Saver, I need some things that I described in a pdf file. Link:
By HA3HZ · #28232 ·
Antenna parameters Re: Nanovnasaver plots
When dealing with a single feedpoint, working with impedances (and a series formulation of R+Xj) is traditional - it maps well into VSWR, etc. However, when working with multiple feedpoints, or
By Jim Lux · #28231 ·
Re: Nanovnasaver plots
Roger: I¡¯ve always thought of the conventional antenna parameter measurement as the antenna being in series, i.e., Z load = Zs = Rs + Xs Cebik notes that, with respect to modeling and looking at
By AG6CX · #28230 ·
Re: Locked, then white screen on NanoVNA-H
Tried this and still just a white screen. I guess it's bricked. Thanks for all the responses. Perry
By Perry Westberry · #28229 ·
NanoVNA-H(4)
Dear, I have a problem with the NanoVNA-H(4) and NanoVNA-App I can connect it on com5 but it does not read the data and mention always a number of points error Does someone has a trick to solve this
By John M. Polard F5VLB · #28228 ·