Firmware Upgrade What Am I Doing Wrong?
Hello everyone in NanoVNA land Newbie here Having trouble upgrading firmware from v0.2.3-2-g8ac9166 date of the build was oct 18, 2019 to the latest firmware. I am able to enter into DFU mode from the
By
A DeCarmo
·
#28268
·
|
Firmware Upgrade What Am I Doing Wrong?
Hello everyone in NanoVNA land Newbie here Having trouble upgrading firmware from v0.2.3-2-g8ac9166 date of the build was oct 18, 2019 to the latest firmware. I am able to enter into DFU mode from the
By
A DeCarmo
·
#28267
·
|
Re: an Old NanoVNA-H
Vince, In addition to reading the Beginner's Guide, please refer to the forum's WIKI page. There is a lot of info there that points to message threads that cover questions already answered over the
By
Larry Rothman
·
#28266
·
|
Re: an Old NanoVNA-H
Roger, Thanks for the link, and I will check out the beginners guide. vince
By
Vince N2AIE
·
#28265
·
|
Re: an Old NanoVNA-H
On Thu, Jun 2, 2022 at 03:30 PM, Vince Loschiavo wrote You can use the latest firmware by DiSlord for your -H. make sure you download the -H version (not the -H4). It is available at this link....
By
Roger Need
·
#28264
·
|
an Old NanoVNA-H
Hi all, newbie, I purchased from a local my NanoVNA-H has version: v0.2.3-2-g8ac9166 date of the build was oct 18, 2019 so I don't brick this OG, what are the chances of updating the firmware to
By
Vince N2AIE
·
#28263
·
|
Re: Which cable measuring method is more accurate - IYHO
@igor-m: that happens when you do not calibrate the specific frequency range prior the Measure->Cable (calibration made directly at the S11 connector). I've tried here with H4 and v1.2 flashed in
By
Pito
·
#28262
·
|
Re: Which cable measuring method is more accurate - IYHO
Hi Dislord, I posted 2 messages yesterday but they were not published here (no idea why). Also pictures did not pass through. H4 v1.2 (built form sources): It was my bad - I forgot to calibrate the
By
igor-m
·
#28261
·
|
Re: Which cable measuring method is more accurate - IYHO
Ok, my bad, I did not calibrate the range before the cable measurement, now the H4 measurement shows Z0=49.71ohm and length=162mm. Fantastic!
By
igor-m
·
#28260
·
|
Re: NanoVNA-H(4)
Your picture shows you do with 51 points. Did you try with 101 or 201?
By
igor-m
·
#28259
·
|
Re: Locked, then white screen on NanoVNA-H
Et voil¨¤ Roger, thanks to you !! 73's jean Marie F5VLB
By
John M. Polard F5VLB
·
#28258
·
|
Re: Which cable measuring method is more accurate - IYHO
I flashed v1.2 last night. Using cal from 2.5-32.5 MHz, 401 p. Changed freq range to 3-5 MHz I have 3X RG316 3660mm 4580mm 4580mm One connected M-F, and the other connected M-M, for a total length of
By
Rich NE1EE
·
#28257
·
|
Re: Locked, then white screen on NanoVNA-H
Thanks for the link, Roger. I'm going to try using it with NanoVNA App. If I feel adventurous, I may try fixing the screen. Thanks for your help. Perry [email protected]> wrote:
By
Perry Westberry
·
#28256
·
|
Re: NanoVNA-H(4)
Thank you Roger, my friend F5WK Michel followed the procedure and all is working for him. Will do the same today. Regards Jean Marie
By
John M. Polard F5VLB
·
#28255
·
|
File /user manual and menu maps/nVNA-H4 v4.3_MS firmware 1.2 menu map 0100 AN14.zip uploaded
#file-notice
The following files and folders have been uploaded to the Files area of the [email protected] group. * /user manual and menu maps/nVNA-H4 v4.3_MS firmware 1.2 menu map 0100 AN14.zip (
By
Group Notification <noreply@...>
·
#28254
·
|
Re: spreadsheet for importing snp files, Excel 2010
Thanks Rich, that's very helpful for those of us using EXCEL for data manipulation or graphing. Your equations are much tidier than what I was using. Rudy N6LF
By
rseverns@...
·
#28253
·
|
Re: Locked, then white screen on NanoVNA-H
This sounds like you may have a defective screen issue. I recall others had this problem and opened up the unit and checked the solder connections. Some cured it by gently re-soldering connections. If
By
Roger Need
·
#28252
·
|
Re: NanoVNA-H(4)
I'm using the latest version installed a few days ago. Perry [email protected]> wrote:
By
Perry Westberry
·
#28251
·
|
Re: Which cable measuring method is more accurate - IYHO
Zack. https://github.com/DiSlord/NanoVNA-D/releases
By
Igor - PY3IG
·
#28250
·
|
Re: Locked, then white screen on NanoVNA-H
A few days ago, I was able to get the unit into DFU mode and it was recognized in Device Manager. I installed the latest Firmware and was still getting a white screen. At the suggestion of another
By
Perry Westberry
·
#28249
·
|