¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Which cable measuring method is more accurate - IYHO
@igor-m: that happens when you do not calibrate the specific frequency range prior the Measure->Cable (calibration made directly at the S11 connector). I've tried here with H4 and v1.2 flashed in
By Pito · #28262 ·
Re: Which cable measuring method is more accurate - IYHO
Hi Dislord, I posted 2 messages yesterday but they were not published here (no idea why). Also pictures did not pass through. H4 v1.2 (built form sources): It was my bad - I forgot to calibrate the
By igor-m · #28261 ·
Re: Which cable measuring method is more accurate - IYHO
Ok, my bad, I did not calibrate the range before the cable measurement, now the H4 measurement shows Z0=49.71ohm and length=162mm. Fantastic!
By igor-m · #28260 ·
Re: NanoVNA-H(4)
Your picture shows you do with 51 points. Did you try with 101 or 201?
By igor-m · #28259 ·
Re: Locked, then white screen on NanoVNA-H
Et voil¨¤ Roger, thanks to you !! 73's jean Marie F5VLB
By John M. Polard F5VLB · #28258 ·
Re: Which cable measuring method is more accurate - IYHO
I flashed v1.2 last night. Using cal from 2.5-32.5 MHz, 401 p. Changed freq range to 3-5 MHz I have 3X RG316 3660mm 4580mm 4580mm One connected M-F, and the other connected M-M, for a total length of
By Rich NE1EE · #28257 ·
Re: Locked, then white screen on NanoVNA-H
Thanks for the link, Roger. I'm going to try using it with NanoVNA App. If I feel adventurous, I may try fixing the screen. Thanks for your help. Perry [email protected]> wrote:
By Perry Westberry · #28256 ·
Re: NanoVNA-H(4)
Thank you Roger, my friend F5WK Michel followed the procedure and all is working for him. Will do the same today. Regards Jean Marie
By John M. Polard F5VLB · #28255 ·
File /user manual and menu maps/nVNA-H4 v4.3_MS firmware 1.2 menu map 0100 AN14.zip uploaded #file-notice
The following files and folders have been uploaded to the Files area of the [email protected] group. * /user manual and menu maps/nVNA-H4 v4.3_MS firmware 1.2 menu map 0100 AN14.zip (
By Group Notification <noreply@...> · #28254 ·
Re: spreadsheet for importing snp files, Excel 2010
Thanks Rich, that's very helpful for those of us using EXCEL for data manipulation or graphing. Your equations are much tidier than what I was using. Rudy N6LF
By rseverns@... · #28253 ·
Re: Locked, then white screen on NanoVNA-H
This sounds like you may have a defective screen issue. I recall others had this problem and opened up the unit and checked the solder connections. Some cured it by gently re-soldering connections. If
By Roger Need · #28252 ·
Re: NanoVNA-H(4)
I'm using the latest version installed a few days ago. Perry [email protected]> wrote:
By Perry Westberry · #28251 ·
Re: Which cable measuring method is more accurate - IYHO
Zack. https://github.com/DiSlord/NanoVNA-D/releases
By Igor - PY3IG · #28250 ·
Re: Locked, then white screen on NanoVNA-H
A few days ago, I was able to get the unit into DFU mode and it was recognized in Device Manager. I installed the latest Firmware and was still getting a white screen. At the suggestion of another
By Perry Westberry · #28249 ·
Re: Nanovnasaver plots
Hello Roger, Op di 31 mei 2022 om 19:40 schreef Roger Need via groups.io <sailtamarack= [email protected]>: It is not me but
By Victor Reijs · #28248 ·
Re: Locked, then white screen on NanoVNA-H
Roger, It now shows in Device Manager. The screen is still while but I can connect with Nanovna Saver and calibrate using the Calibration Assistant. Do you think it's usable when connected to the
By Perry Westberry · #28247 ·
Re: Which cable measuring method is more accurate - IYHO
The measure feature works well...from the user manual 1.2.5 MEASURE 3. CABLE S11 Choose a frequency range such that the cable length is ~1/4 of the wavelength in the middle of the range. This feature
By Rich NE1EE · #28246 ·
Re: Nanovnasaver plots
I do not own a VNWA so I have no first hand knowledge to share. From what I have read it has better specifications than a NanoVNA. You could join the VNWA group and pose your question there...
By Roger Need · #28245 ·
Re: Nanovnasaver plots
Hi Roger: Thanks for your comments and focus on dispelling the notion that S11 with nanoVNA might be inappropriate for high(er) impedance measuring. Re: ¡°The intent of my post was to reply to
By AG6CX · #28244 ·
Re: Locked, then white screen on NanoVNA-H
Hello, Being a past bata tester of FW for this unit, I have dealt with your problem. The way I cured it is as follows: First shut down the NanoVNA. Remove the back cover. Using small tweezers or what
By Clyde Lambert · #28243 ·