QUOTE: I don't see any way to verify calibration with Saver but what I do
is setup the frequencies that I want to check before doing calibration.
..........................................................................................................................
You are correct in setting up your frequency span before doing the cal. in
Saver.
However, it is easy to check cal. once it is run in Saver. Use the same
standards you used for cal. and sweep each one at a time. The short should
show a short - extreme left of the Smith Chart. The open should show an
open - extreme right of the smith Chart. The 50-ohm standard should be
bullseye in the center of the Smith Chart. It's that simple.
Dave - W?LEV
On Wed, Aug 2, 2023 at 7:53?PM Steven KC3DOW via groups.io <treasurebox7762=
[email protected]> wrote:
Hi Barry,
Not a 'J' pole. It is a Diamond X-50A. My previous antenna was a 'J' pole
but did not reach an area that I needed to reach.
This Diamond does the job but I am trying to train myself to use the
NanoVNA-H and learn Saver when I ran into the problem. I was trying to
check swr to see if it was within specs.
By the way. I did the calibration correctly and by the book and also did
the verification which was successful.
I don't see any way to verify calibration with Saver but what I do is
setup the frequencies that I want to check before doing calibration.
Thanks for your help,
Steven/kc3dow
--
*Dave - W?LEV*
--
Dave - W?LEV