On 2022-05-12 11:57:-0700, you wrote:
H/H4 firmware by default apply internal delay if set and after send it ti CPU. You must reset on device before use Saver software.
Thanks...I was using an existing cal, and was resetting the delay to zero before connecting with the software. It makes sense that the delay will be sent to Saver if Saver uses VNA calibration.
I was puzzled by 2 things
1. The calibration I /thought/ I did a few days ago is actually off by 20 degrees now
2. Saver did not apply the same offset to get the same sweep to 0 phase degrees
I will reset, recal, rerun Saver. Having several ops here report that Saver worked as expected means that I don't have the cal I thought I had.
~R~