Jay,
I can confirm that the CP file to change is DMKSYS ASSEMBLE.
You will need to check which is the current file.
I am in the process of changing my 3 pack, 4 packs, 5 packs and 6 packs
to have the line:-
SYSTIME ZONE=1,LOC=EAST,ID=BST .
Having done that you need to assemble the file using
VMFASM DMKSYS DMKHRC
and then generate the CP nucleus.
Details of this for the 6 pack are in SYSPROG MEMO.
I haven't yet looked at CE 1.1.1.
Each build of VM370 seems slightly different.
CE 1.1.1 seems to be detailed in MAINT MEMO.
Chris
--
<cjar1950@...>
----------------------------------------------------------------------------------------------------------------------------------
On Sat, 9 Apr 2022 13:53:15 -0500
"Joe Monk" <joemonk64@...> wrote:
SYSGEN for CP.
Macro is SYSTIME. Page 175 in this book...
Joe
On Sat, Apr 9, 2022 at 12:15 PM Jay Maynard <jaymaynard@...> wrote:
OK, so for this VM n00b, how do I set the timezone like I would with
PARMTZ in MVS? I'm using the CE 1.1.1 to run the TK4- system. I know the
hardware TOD clock runs in GMT, but I'd like other things to run on CDT
(GMT-5)...so, for example, the auto monitor start and stop runs at 9 and 5
like they're supposed to instead fo 4 and noon, and so on.
--
Jay Maynard