¿ªÔÆÌåÓý

Re: Any Good Reason to Create a Hierarchical Connector and Conductors to Route (Plumb) Ground Out of a Hierarchical Schematic


 

¿ªÔÆÌåÓý

Ah, yes. I had forgotten that. Thanks.

--
Regards,
Tony


On 05/02/2025 14:21, Andy I via groups.io wrote:

Technically, the "hidden" connection is to a not-hidden pin on the A-device symbol's lower left corner.? If the pin is left floating, which is the normal way to use them, LTspice makes a hidden to node 0.? If the pin goes anywhere on your schematic, the connection to node 0 is broken, causing the output currents to be sourced from something other than node 0.

Join [email protected] to automatically receive all group messages.