More: You don't see any LPF
effect because you set K to 1, so there is no leakage
inductance. If you set K to say 0.98 you will see a filtering
effect.
======================================================================================
Best wishes
John Woodgate OOO-Own Opinions Only
Rayleigh, Essex UK
I hear, and I forget.
I see, and I remember.
I do, and I understand.
Xunzi (340 - 245 BC)
On 2023-07-08 21:22, John Woodgate
wrote:
toggle quoted message
Show quoted text
Present: far too much stuff
not relevant to the question of the transformer acting as a
low-pass filter.
Kerim, if you accept that a
two-winding transformer acts as a low-pass filter, you
should be able to see that the presence of a third winding
doesn't change that.? The leakage inductance and the load
resistance are still there, as for the two-winding
transformer.
======================================================================================
Best wishes John Woodgate OOO-Own Opinions Only
Rayleigh, Essex UK
I hear, and I forget. I see, and I remember. I do, and I
understand. Xunzi (340 - 245 BC)
On 2023-07-08 21:13, Andy I wrote:
Missing:
? ? 74hc86.asy
? ? 74hc.lib
Andy