Re: Push-Pull 3-Winding Transformer Model Acting as LPF too?


 

¿ªÔÆÌåÓý

Present: far too much stuff not relevant to the question of the transformer acting as a low-pass filter.

Kerim, if you accept that a two-winding transformer acts as a low-pass filter, you should be able to see that the presence of a third winding doesn't change that.? The leakage inductance and the load resistance are still there, as for the two-winding transformer.

======================================================================================
Best wishes John Woodgate OOO-Own Opinions Only

Rayleigh, Essex UK

I hear, and I forget. I see, and I remember. I do, and I understand. Xunzi (340 - 245 BC)