Re: Erratic function of Commander 5.8.7
-----Original Message-----AA6YQ comments below From: dxlab@... [mailto:dxlab@...]On Behalf Of cergender Sent: Saturday, September 05, 2009 7:07 AM To: dxlab@... Subject: [dxlab] Re: Erratic function of Commander 5.8.7 Had to clean everything regarding Commander from the registry before v.7.9.2 started performing OK. Seems to be fine now. New version 7.9.2 however did not make any entry to the control panel/add/remove programs. applet doesn't show Commander in its list of installed programs? On theAre you saying that the Windows Control Panels' "Add/Remove Programs" Launcher's Main window, what color is the LED-like display above the CMD button? Question: I how to remove it safely one day again. <>If an application is improperly registered with Windows, see 73, Dave, AA6YQ |
Re: Pathfinder 457 one minor / one wish
Carl Smidt
Hello Dave,
I have lost access to Pathfinder. Have been inactive for many months now, but with winter just ahead I might just get back into action again. Your help appreciated. 73, Carl VE9OV E-mail message checked by Spyware Doctor (6.1.0.447) Database version: 6.13200 |
Re: WinWarbler configuration problem
wc5m
Turned out to be a hardware problem. The Signalink interface has some internal jumpers to configure which signals go on which wires in the cable to the rig. One of the jumpers was loose.
toggle quoted message
Show quoted text
Mark WC5M --- In dxlab@..., "aa6yq" <aa6yq@...> wrote:
|
Re: Pathfinder will not auto populate WW Name & QTH details.
Terry G0TMX
Hi Dave,
toggle quoted message
Show quoted text
Thankyou for your response... I have re-checked all my settings and am happy to confirm they are all as you state they should be. Still no joy with 'auto populate' the WW Log fields.... 73 de Terry, G0TMX. FIST #1862 - Loc JO02IF. WAB - TL86 Echolink Gateway on 434.475Mhz 110.9hz Bury St Edmunds, Suffolk, United Kingdom. ----- Original Message -----
From: aa6yq To: dxlab@... Sent: Friday, September 04, 2009 7:13 PM Subject: [dxlab] Re: Pathfinder will not auto populate WW Name & QTH details. WinWarbler cannot use QRZ.com as a callbook unless both DXKeeper and Pathfinder are running, and the Callbook tab of DXKeeper's Config window is configured for "QRZ.com via Pathfinder". As a result of changes to QRZ.com last week, the QRZ.com URL on Pathfinder's Config window must be set to {TargetCallsign} 73, Dave, AA6YQ --- In dxlab@..., "g0tmx" <g0tmx@...> wrote: > > Hi Gang, > > I'm currently running with PF 4.5.7 and WW 6.4.8 and I have run into an issue where upon hitting return from entering a callsign in WW Call Box, the program will not auto populate the name and QTH details from the QRZ lookup performed by Pathfinder. Manually looking at the PF results box, the lookup has been performed without error on QRZ.com. I have seen several references to this in other posts, but am I missing something common in the set up, since the last improvements to DXLab? > > 73 de Terry, G0TMX. > |
Re: Erratic function of Commander 5.8.7
Upgrade releases do not make any changes to Add/Remove programs. All they do is replace some already existing files. DXLab programs are registered during the installation of the initial full release which in the case of Commander is V 5.8.7. Did you install version 5.8.7 and then upgrade it to V 7.9.2? If you use Launcher to install the applications this will all be taken care of for you but if you install manually then you have to follow the installation directions do it yourself.
toggle quoted message
Show quoted text
73, Rich - W3ZJ cergender wrote: Had to clean everything regarding Commander from the registry before v.7.9.2 started performing OK. Seems to be fine now. |
Re: Erratic function of Commander 5.8.7
Had to clean everything regarding Commander from the registry before v.7.9.2 started performing OK. Seems to be fine now.
New version 7.9.2 however did not make any entry to the control panel/add/remove programs. Question: I how to remove it safely one day again. Ben |
Re: Deleting a block of contacts
-----Original Message-----AA6YQ comments below From: dxlab@... [mailto:dxlab@...]On Behalf Of Buzz Sent: Friday, September 04, 2009 4:22 PM To: dxlab@... Subject: [dxlab] Deleting a block of contacts Hello, It has been too long since I had to do this. Dave has advised me in the past about how to delete a large number of contacts in the log (imported some by accident). I cannot remember how to do this task and I cannot find it in the help file. Delete function easier to locate. Thanks...In the next version of DXKeeper, I have made the documentation of the 73, Dave, AA6YQ |
Re: Pathfinder 457 one minor / one wish
Bernard, I've emailed you a corrected version of Pathfinder that ensures the
toggle quoted message
Show quoted text
Callsign box has focus and that its cursor indicator is visible after completing a search. Please let me know how it goes; thanks... 73, Dave, AA6YQ -----Original Message-----
From: dxlab@... [mailto:dxlab@...]On Behalf Of Bernard Grijpstra Sent: Thursday, September 03, 2009 4:04 PM To: DX-Lab Yahoo Group Subject: [dxlab] Pathfinder 457 one minor / one wish Hello Dave , One minor for PF : When focus is transferred from another window to pf window the cursor indicator is visible in the 'enter call' field. However when focus was in pf window (while checking out a qrz entry for example) and you return the focus to the entry field of pf by clicking in it the cursor indicator is invisible making editing of a call already in it a little bit difficult. My wish for pf : To transfer a call from fe SC to PF you will have to double click a SC row , at the same time the DXK capture window is filled. How about just sending the call to pf on selection in SC, i like to check a call for fun in qrz via PF but need to clear the capture window every time afterwards. Best regards, Bernard Grijpstra PA3FZV ------------------------------------ Yahoo! Groups Links No virus found in this incoming message. Checked by AVG - www.avg.com Version: 8.5.339 / Virus Database: 270.13.74/2339 - Release Date: 09/03/09 05:50:00 |
Re: (unknown)
On the Launcher's Config window, try a different distribution site. Does
toggle quoted message
Show quoted text
this enable you to download Pathfinder 4.5.7? 73, Dave, AA6YQ -----Original Message-----
From: dxlab@... [mailto:dxlab@...]On Behalf Of j mayfield Sent: Friday, September 04, 2009 6:19 PM To: dxlab@... Subject: [dxlab] (unknown) ok dave well the version im running is 4.5.6 for pathfinder tried to update it but it says cant download not sure why this is i dont have commander installed cause it wont let me download either but i dont have any rig control stuff??? anyways jeff ke7ace ------------------------------------ Yahoo! Groups Links No virus found in this incoming message. Checked by AVG - www.avg.com Version: 8.5.339 / Virus Database: 270.13.74/2339 - Release Date: 09/04/09 05:51:00 |
Re: (unknown)
Richard W. Solomon
I get that quite a bit. I just go to the top and change the Download site.
toggle quoted message
Show quoted text
Works every time. 73, Dick, W1KSZ -----Original Message-----
From: j mayfield <ke7ace@...> |
(No subject)
j mayfield
ok dave well the version im running is 4.5.6 for pathfinder
tried to update it but it says cant download not sure why this is i dont have commander installed cause it wont let me download either but i dont have any rig control stuff? anyways jeff ke7ace [Non-text portions of this message have been removed] |
Re: DOK references
I have here a printed DOK list from DARC Verlag dated 22.7.1991
It shows IBO78 till IBO99 same for IR83 till IR99 UKW88 till UKW99 VHV86 till VHV99 CM80 till CM99 (and I know there are more after this one) now many with start 25, 40 or 50 and the original DOK behind that number. But I suggest if you work one of these (now CM2008 or IFA09, currently active) just add them, they are shorttime and will not be reactivated after the year is over or the activity period is past. This counts every year anew, and that's why the SonderDOK count now is higher than the original DOK count 73 Nico, pa0mir |
Re: CW Character Spacing
DANNY DOUGLAS
Chuck would you happen to be using a Kenwood TS570 ?
toggle quoted message
Show quoted text
Danny Douglas N7DC ex WN5QMX ET2US WA5UKR ET3USA SV0WPP VS6DD N7DC/YV5 G5CTB All 2 years or more (except Novice) Pls QSL direct, buro, or LOTW preferred, I Do not use, but as a courtesy do upload to eQSL for those who do. Moderator DXandTALK DXandTALK@... Moderator Digital_modes ----- Original Message -----
From: k4pby To: dxlab@... Sent: Friday, September 04, 2009 2:35 PM Subject: [dxlab] CW Character Spacing Hello--I am new to the group. I am using WinWarbler ver 4.5.0 and have been very pleased with it. I have one problem that I am trying to solve though. When operating CW someties characters get run together with no spacing. For instance, AN would be transmitted as a P.The transmit window indicates AN but P is actually sent (AN with no character spacing). This does not happen all of the time but ofen enough that I don't trust it. I have tried varying the character spacing value and other parameters on the cw setup but it still happens.I would appreciate ieas on a solution. My CW setup is configured as so: Keyboard Mode(auto stop,auto start,character) and Weight(Dot/dash 1:3,element space 1, character space 3, word space 3) Thanks--Chuck K4PBY |
Re: capture window question...
-----Original Message-----AA6YQ comments below From: dxlab@... [mailto:dxlab@...]On Behalf Of Ron Rossi Sent: Friday, September 04, 2009 3:53 PM To: dxlab@... Subject: [dxlab] capture window question... Folks, I enter a new call in the capture window when a previous call and data are already in the window. When I TAB or ENTER all the information is updated with the new call data except the name and QTH. These values stay at the previous state. Is there a reason for this? I see that pressing SHIFT will clear the data first and then only new data is there. I guess I would have expected that would be the default behavior. I can remember to keep shift pressed to have it work the way I expected (after reading the Wiki). Maybe I am more wondering why it works the way it does? the lookup operation, the lookup operation doesn't overwrite what you'veSo that if you record information received over the air before you invoke already recorded. 73, Dave, AA6YQ |
Re: Deleting a block of contacts
Art Searle
Hi Buzz
toggle quoted message
Show quoted text
First, back up your log. Then filter your log for the QSOs you want to delete. Did you backup your log? Then press Control plus the Delete button on DXK main page. BTW Did you backup your log first? 73 Art W2NRA "Keep to the Code!" w2nra.com On Sep 4, 2009, at 4:22 PM, Buzz <n5ftr@...> wrote:
Hello, |
Deleting a block of contacts
Buzz
Hello,
It has been too long since I had to do this. Dave has advised me in the past about how to delete a large number of contacts in the log (imported some by accident). I cannot remember how to do this task and I cannot find it in the help file. Any assistance would be greatly appreciated. 73, Buzz - NI5DX |
Re: CW Character Spacing
k4pby
--- In dxlab@..., "Dave AA6YQ" <aa6yq@...> wrote:
Thanks very much for your reply and yes I am runing a bit light computer wise. I think I will try the WinKeyer approach--I have built some of K1EL's other kits in the past. BTW,I am new to operating the digital modes and found your WinWarbler software to be the one I liked best after playing with a few others. Nice work! 73--ChuckAA6YQ comments below:Windows is not a real-time operating system......With that setting, Windows is generating the CW timing. Unfortunately, |
capture window question...
Ron Rossi
Folks,
I enter a new call in the capture window when a previous call and data are already in the window. When I TAB or ENTER all the information is updated with the new call data except the name and QTH. These values stay at the previous state. Is there a reason for this? I see that pressing SHIFT will clear the data first and then only new data is there. I guess I would have expected that would be the default behavior. I can remember to keep shift pressed to have it work the way I expected (after reading the Wiki). Maybe I am more wondering why it works the way it does? Thanks. -- 73 es God Bless de KK1L...Ron Rossi (kk1l@...) <>< QTH: Jericho, Vermont My page: |
Re: CW Character Spacing
-----Original Message-----AA6YQ comments below From: dxlab@... [mailto:dxlab@...]On Behalf Of k4pby Sent: Friday, September 04, 2009 3:14 PM To: dxlab@... Subject: [dxlab] Re: CW Character Spacing --- In dxlab@..., "aa6yq" <aa6yq@...> wrote: panel? Hi Dave---It is configured Parallel Port (LPT3 Data 5 pin 7) Windows is not a real-time operating system, so even though WinWarbler runsWith that setting, Windows is generating the CW timing. Unfortunately, its CW-generation at the highest possible priority, simply moving your mouse while transmitting CW can yield erratic timing. If you have other applications simultaneously running, or if your PC is light on horsepower and/or RAM, these factors can contribute to the problem. Minimizing the load on your CPU and RAM while working CW is the least expensive approach. Another approach is to acquire a WinKey -- a small hardware device that accepts characters from WinWarbler and does the CW generation. You can build a WinKey serial port kit for as little as $36 (see <>) or you can purchase a fancier USB kit for about double that price (see <>). Several commercial products also incorporate WinKey circuits, e.g. MicroHam's product line (see <>). WinWarbler can also use a KAM, PSK232, or MFJ HF modem as a CW generator; these are often inexpensively available via flea markets or EBay (e.g. see < QQcmdZViewItemQQptZLH_DefaultDomain_0?hash=item19b622795e&_trksid=p3286.c0.m 14#ht_2088wt_1165>). 73, Dave, AA6YQ |