Make sure you use both my VITA49 and FlexRadio v6 flows. They are in a single zip file. ?Read the comment nodes in both. You need to set the IP to the radio IP in the TCP FlexRadio flow and the ping node in the VITA49 flow. Start Node Red first, then connect the client.

Dave wo2x

On Feb 26, 2021, at 10:57 PM, Charlie Rubenstein <charlier@...> wrote:

?Well.....at least it worked LAST night.....tonight the ClientStatus is NULL....don't know why. I even went to the Flex Radio flow of yours and put a debug node on the output of?? and it was nothing coming out of it.

BUT, I found another way......I found that the json string that comes from FRStack sends a "0" for the S-Meter when the radio is disconnected.
So, I made a switch that only passes the S-meter number when the number is < 0 (port 1), and if the number is equal to "0" (port2) I had a change node set the payload to -120 (which zeros the meter).? It's working that way.

Charlie KB8CR