Hi Oristo
Yes if you load is also perfect 50ohm but such a load cost many $ ? although the load supplied with the NanoVNA is pretty fine and you correctly mentioned "observe no appreciable reflection" which requires both the candidate cable and load are good quality. Have a look at AC6LA home page about ZPlots and the his coac calbe information where you see the velocity factor which has influence on the delay is frequency dependent. He has a direct graph on this issue
Good luck with your experiment
Kind regards
Kurt
-----Oprindelig meddelelse-----
Fra:
[email protected] <
[email protected]> P? vegne af Oristo
Sendt: 4. oktober 2019 22:59
Til:
[email protected]Emne: Re: [nanovna-users] Cal-Kit Standards' Definitions
Thanks for the response!
Remember the Electrical delay assumes and ideal 50 transmission line
So, if I
* properly calibrate at the VNA port
* plug in a candidate cable terminated with calibration load
* observe no appreciable reflection
.. then that cable unterminated should be satisfactory for delay testing..