Re: #measurement - Torroid #measurement


 

I should have said that type 43 reads like an open circuit .

On Wed, Jun 21, 2023 at 1:44?PM Gene Ruff <ruff.gene@...> wrote:

a useful hint when identifying torrides type 31 has resistance across the
surface . type 43 has none. Different materials.

On Wed, Jun 21, 2023 at 1:23?PM W0LEV <davearea51a@...> wrote:

43 or 31 material are appropriate for HF applications. 43 is better for
20-meters upward and 31 material is best for 160 through 40 meters. If
you
are sure you have 43 material, there really is no reason to test the
toroids.

Dave - W0LEV

On Wed, Jun 21, 2023 at 12:48?PM Kurt Heernaert <on4cgw@...> wrote:

Dears,

FT240-43 Torroid, Can I use my NanoVNA to meassure my several torroids
to
be sure that I have the correct ones for HF UNUN?

any info is welcome

73,
Kurt





--

*Dave - W?LEV*


--
Dave - W?LEV





--
*Gene Ruff*
--
*Gene Ruff*