H4, Saver 0.4.0 e-delay


 

I saw a post about problems with Saver, and the ini file, so I renamed mine, and ran Saver.

I have a cal that is reliable.
The H4 shows the proper e-delay and phase change for an SMA adapter and for a coax extension.

Saver?
Rats. The e-delay is way off...
Then I looked at it not for its value, but for how it related to the H4.
It is half the H4.
The delay in Saver was 730 ps and when I shutdown Saver, disconnected, and restarted H4, I put 1460 ps in e-delay. That zeroed phase.

This is another example of how the lack of consistency across product lines and the lack of docs causes problems.

I don't understand why some earlier posters in threads related to this didn't comment. Surely mine cannot be the only H4 and Saver combo that works this way. I don't care which method is used, but I should not have to experiment to see what fields mean.