In your Logger32.INI under the [Globals] section, you may see a line like this:
?
Show Radio Control Panel=True
?
If so, try changing it to:
?
Show Radio Control Panel=False
?
If not, add that line to the [Globals] section: hopefully, that should stop Logger32 trying to launch and display the Radio Control Panel as it starts up ¡ which hopefully will get you past the problem step.?
?
However, we may be chasing phantoms here: the actual problem may be something different, not the RCP at all ¨C perhaps something going wrong after the RCP launches OK.
Ciao John, for first tnx so much for your fast reply.
I have already done this by deleting the RadioPanel.ini file and the result does not change.
The PC is the same, I was installing a new W10 on a new HD in the same PC, so the peripherals are exactly the same.
I repeat: this is not the first time I try to move Logger32 to a new installation and everything has always been fine.
Only now I can't understand why I can't
73's, Lenio - IZ5ILJ - #69.
Il 29/07/2021 00:22, John Munton - G7SSE ha scritto:
Lenio
?
As a test find in your Logger32 directory the file: RadioPanel.ini? and temporally remove or rename it to?RadioPanelBad.ini or something.
?
Run Logger32 and try to start the RCP, it will load with default settings. Does it run ok?
?
If so the problem is in the your transferred ini file.
?
One thought (guess); could the RCP be looking for an audio device, which is either not present on your new system or is under a different name in Windows compared to your old one?
?
Another is did you use a custom font, just for the RCP, that is not installed on your new system?
?
You can open the RCP ini file with Notepad to check.
Subject: Re: [hamlogger] Porting Logger32 from old PC to new PC
?
Ciao to all, I did everything as specified, both for the accessory programs and fonts, and it starts normally, however, when the program "radio control panel" appears in the loading window, after a few seconds it freezes and exits from loading.
?
I've tried many and many times but just can't figure out what's going on.
?
I had done this before and everything had worked but now he just doesn't want to know.
?
Tnx in advance for any help,
?
73's, Lenio - IZ5ILJ - #69.
?
Il 27/07/2021 16:25, Gary Hinson ha scritto:
Aside from the auto-start utilities, you might also need to check that the particular fonts used in your installation of Logger32 are installed on the new PC.
?
Oh and if it is not stored in the Logger32 folder that you copied, you'll also need to transfer your log across - preferably doing a full ADIF export from the old PC, then an import on the new one.