Re: Inrush filament current protection
No electrical difference here; but if the breaker box is to be used as a sub-panel, you need seperate bus bars for the neutrals and grounds with a removable shorting strap between the two. Only in the
By
Phil Clements <philc@...>
·
#1042
·
|
Re: Inrush filament current protection
I get along with my guy very well for the reasons you stated. Life is short and best to get the inspector out of it ASAP. "Robert B. Bonner" <rbonner@...> wrote: Yeah some of these guys interpret
By
FRANCIS CARCIA <carcia@...>
·
#1041
·
|
Re: Inrush filament current protection
Yeah some of these guys interpret the code differently¡ Have their own opinions. That¡¯s why there are lawyers and judges, hahahaha My local inspector considered the water pipe as the real
By
Robert B. Bonner <rbonner@...>
·
#1040
·
|
Re: Inrush filament current protection
See below ________________________________________ From: ham_amplifiers@... [mailto:ham_amplifiers@...] On Behalf Of KR4DA Sent: Monday, November 13, 2006 10:31 AM To:
By
Robert B. Bonner <rbonner@...>
·
#1039
·
|
Re: Inrush filament current protection
Not in California, it's set at 228v to 240v by the PUC. I do not believe everything in any book.
By
R L Measures
·
#1038
·
|
Re: NOS cermic-metal tube burn in
What is the screen PS V? What is the anode PS V? What Class? R L Measures, AG6K, 805.386.3734 r@..., rlm@..., www.somis.org
By
R L Measures
·
#1037
·
|
Re: Inrush filament current protection
My building inspector did not want the ground wire in the meter socket. I ran conduit off the breaker panel to the rods. I also ran #4 over to the water main both sides of the meter. Then I showed him
By
FRANCIS CARCIA <carcia@...>
·
#1036
·
|
Re: Inrush filament current protection
By
Robert B. Bonner <rbonner@...>
·
#1035
·
|
Re: 3-500Z socket.... Johnson vs Eimac
Rich, it says 0.082" at sea level and 500W dissipation 73 Peter
By
Peter Voelpel <df3kv@...>
·
#1034
·
|
Re: Inrush filament current protection
210-250v depends on the utility company... My experience and I am not certified.... read any basic book on it..... I have done most of the wiring around my house.. a well and the pool and the 24x30
By
KR4DA <kr4da@...>
·
#1033
·
|
Re: 3-500Z socket.... Johnson vs Eimac
The Eimac spec sheet says 0.82" at sea level. Opinions count way less than manometer measurements.
By
R L Measures
·
#1032
·
|
Re: "Father Measures"
Hardly, Jim. I know too much about history to ever join any organized religion. cheers R L Measures, AG6K, 805.386.3734 r@..., rlm@..., www.somis.org
By
R L Measures
·
#1031
·
|
Re: Inrush filament current protection
Is not 240v standard in the United States? If they connect together in the breaker box, is this really safe? ... ... > R L Measures, AG6K, 805.386.3734 r@..., rlm@..., www.somis.or
By
R L Measures
·
#1029
·
|
NOS cermic-metal tube burn in
Hi, There are two Chinese FU-251F(4CX250B) cermic-metal tubes, they are new but storge for very long time. The output power only 200-250W( a pair), Could someone cal tell me how to solve this
By
Hsu <Jbenson@...>
·
#1030
·
|
Re: Inrush filament current protection
Jim, I know several years ago a friend sent me some copies of the posts on AMPS when I wasn't a member. There were comments rather heated regarding POWER SERVICES and AC wiring to amps. I will end
By
Robert B. Bonner <rbonner@...>
·
#1028
·
|
Re: "Father Measures"
make a good priest. Maybe they were joking?... ### I can just see it now.... "Father Measures" ... up on the mound.. preaching a fire and brimstone lecture about..."parasitic hell"....to us globar
By
pentalab <jim.thomson@...>
·
#1027
·
|
Results of removing grid fuse + cathode fuse
OK, here's the deal. I had my buddy with the 3x6 remove the fast 750 ma grid fuse from the 3agc fuse holder... then try and apply 800w of drive. INPUT SWR on the big amp goes sky high.... and then the
By
pentalab <jim.thomson@...>
·
#1026
·
|
Re: Can a ..power factor correction cap be used on the input of a Plate Xfmr ??
### Yes.. pse do. It would be much appreciated as I have hit a dead end here. That value though seems way to much at 35 uF for this. Placed across the primary leads, it will start looking like a short
By
pentalab <jim.thomson@...>
·
#1025
·
|
Re: ARRL - Political - was: Filament Voltage regulator
In West Hollywood, this would be considered a perquisite. Correct, Frank, which is why they adopted the priestly vow of not to do women 9-centuries ago. Right, and Bernard Law gets an allowance of c.
By
R L Measures
·
#1024
·
|
Re: 3-500Z socket.... Johnson vs Eimac
requires a high-pressure centrifugal blower, and Ham amps used an ordinary centrifugal blower. pressure. RICH SEZ... Correct, but Eimac's 0.82" water column spec is the pressure differential across
By
pentalab <jim.thomson@...>
·
#1023
·
|