--- In ham_amplifiers@..., R L Measures <r@...> wrote:
Rich sez So how can a 3-500 be gettered by running the
filament only?
###### It can't !! 3-500'z don't have any internal filament
heat activated getter's....end of story.
Rich sez...So operating the filament of a new one for 48-hrs does
nothing to getter the tube?
### Correct ! 0-48 hr- 48 days on a new 3-500Z will NOT
getter the tube..... from fil heat. There are NO heat activated
getter's on a 3-500Z. On a 3-500Z.... u gotta get the anodes
to show some colour.
### On a metal tube.... different story [thoriated tungsten fil
only] They do have 4 x getter's.... that are fil heat
activated.
### I just checked... and Eimac suggests to run the fil's
only... no HV..... "for several hours" ..on a new or rebuilt
tube. Bake em for 48 hrs as suggested.... and you are
laughing.
Jim VE7RF