Re: Issues running OS/360 MVT unter VM/SP 5
I tried testing this on VM/ESA and ran into some problems. When defining the guest in USER DIRECT, I gained the TODENABLE option, however I lost REALTIMER and ISAM, which the manual for VM/SP says are
By
Jeff Snyder
·
#5074
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
The year 1955 cannot be represented in a TOD clock using the MVT epoch of 1960, so - although the wording is odd - it doesn't surprise me that it won't accept it. But I don't remember how the TOD
By
Tony Harminc
·
#5073
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Hi Chris, It looks like that gets us outside MVT's sanity check range: | 00 IEE116A TOD CLOCK INVALID- REPLY WITH SET PARAMETERS | R 00,'CLOCK=01.01.01,DATE=55.066,AUTO=N' | IEE600I REPLY TO 00 IS;
By
Jeff Snyder
·
#5072
·
|
Re: Is the following automation possible?
Do you mean with IND$FILE? If so, the answer is yes. ASCII. You may watch this video: https://www.youtube.com/watch?v=U-kFCsiqB0c (sorry if it is a little long) Cheers, Rene FERLAND, Montreal
By
Ren¨¦ Ferland
·
#5071
·
|
Re: Is the following automation possible?
Hello Rene, Thank you for your message and information. Question: On REDIT and WINMMG can I upload them via the built in wc3280 and CMS method? Are they binary or ASCII or ??? BTW, How do you transfer
By
Bertram Moshier
·
#5070
·
|
Re: Is the following automation possible?
In 2008, Robert O'Hara wrote a small Windows program to achieve that purpose. It is called VMconsole.exe. It is essentially a modified telnet client. You connect to VM/370 using it with a command like
By
Ren¨¦ Ferland
·
#5069
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Jeff, It looks most odd, as the time is also corrupted. What happens if you change the order of the reply thus:- R 0,'DATE=55.066,CLOCK=01.01.01,AUTO=N' (that's the format in my notes for MVT). Chris
By
cjar1950@...
·
#5068
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Hi Uwe.? Using 28 years set the date back to 1995, which should have fit within MVT's sanity check for dates.? When I did that, MVT thought it was 1955.? I'm afraid if I go back any further, I
By
Jeff Snyder
·
#5067
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Tony, Unfortunately, this option is not available to VM/SP5.? However, I have a VM/ESA image available to me, I may try looking over there and see if this is an option.? I'm afraid that if I get too
By
Jeff Snyder
·
#5066
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Hi Fish, thanks for the input.? Unfortunately, this approach has a couple drawbacks that limit its usability for me: 1.? When submitting the jobs in the fashion you describe, they are not presented
By
Jeff Snyder
·
#5065
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Jeff- Have you tried to set the VM date set back 56 years? A multiple of 28 and sets the date back before 2000 for MVT. -Uwe
By
h390@...
·
#5064
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Hi Tony, Thanks for the feedback.? Kevin Leonard has said that the next MVT Turnkey will have support for dates beyond 1999.? For now, I'm just working to get MVT to coexist with VM and get the best
By
Jeff Snyder
·
#5063
·
|
Re: Is the following automation possible?
Bertram, Its pretty usable. Easiest way to see what does and does not work is to open EE (you need a file name & type) type HELP. Use PF2 to see the individual files. Dave Sent: Wednesday, March 8,
By
Dave Wade
·
#5062
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
By
Dave Wade
·
#5061
·
|
Re: Is the following automation possible?
Hi Bertram, the documents are at https://github.com/devhawala/mecaff/tree/master/publications/v1.2.5 I understood that Bob Bolch is working on ironing out some of the difference, and mostly to enable
By
[email protected]
·
#5060
·
|
Is the following automation possible?
Hello, I'm not understanding how to use the EE editor as a XEDIT replacement. Are there good instructions on doing this and what is not woriing? Given EE is not yet working like XEdit. I'm wondering;
By
Bertram Moshier
·
#5059
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
On Tue, 7 Mar 2023 at 21:46, Fish Fish <david.b.trout@...> wrote: [...] >> 2. Clock issues in VM > > I don't know if this is valid in VM/SP 5 (too lazy to check), but I found this: > > *
By
Tony Harminc
·
#5058
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
Jeff Snyder wrote: The following are just *guesses* based on aging memory: [...] Maybe you just need to spool your punch "CONT" before punching your jobstream, and then "CLOSE" it afterwards? *
By
Fish Fish
·
#5057
·
|
Re: Issues running OS/360 MVT unter VM/SP 5
[...] I don't know Since STCK is an unprivileged instruction, there is nothing VM/
By
Tony Harminc
·
#5056
·
|
Issues running OS/360 MVT unter VM/SP 5
I am running Kevin Leonard's Turnkey MVT under VM/SP 5 and I've run into a couple issues I'm hoping someone here may be able to help me with. *1. VM sends EOF to the reader on input* When I am running
By
Jeff Snyder
·
#5055
·
|