Dave Wade wrote:
[...]
It looks like when on OPERATOR with CMS loaded, and you
change store it does not report Disabled Wait Loaded.
I am not sure if it should. I¡¯ll check on the base software.
FWIW, it appears that with z/VM, it doesn't load a disabled wait PSW after redefining storage either. Instead, it simply resets the system and clears storage ("Storage cleared - system reset"), leaving the user in CP mode, thereby requiring you to ipl cms again if you want to be able to issue CMS commands.
And if your run mode is set to run ("q set" shows "RUN ON", which is usually the case for the OPERATOR userid as I recall), there's no indication that you're actually in CP mode after the system has been reset either. Instead, "RUNNING" still appears in your status area, even though you are actually in CP mode.
On a regular user with a normal run mode of off ("q set" shows "RUN OFF"), whenever you redefine storage (and get the normal "Storage cleared - system reset" response), your status changes to "CP READ", letting you know that you have to reipl cms if desired.
I'm sure VM/370 behaves the same way in this regard, although I admit to not having bothered to check.
--
"Fish" (David B. Trout)
Software Development Laboratories
mail: fish@...