¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: Hf+50 MHz power loss


 

¿ªÔÆÌåÓý

Many thanks indeed Andrew, will do.

73s

Emilio

Il 25/08/23 22:32, Andrew Lenton ha scritto:

They are not test points but links, you have to remove and insert an amp meter and measure the current, it is in the service manual, first check the I/P to the amp first.

From memory something lile 400ma and 1 amp, the bias pots are known to fail

73

Andrew

Get
On 25 Aug 2023, at 21:00, "ik0oky via " <yahoo.it@groups.io target=_blank>[email protected]> wrote:

Yes, will have a look at the test points of the HF PA unit

Thanks

Il 25/08/23 11:03, Andrew Lenton ha scritto:
The HF PA is under the main board, tricky to get to but doable

73

Get

Join [email protected] to automatically receive all group messages.