Re: Procedure to shut down a system without a gatevalve to the diffusionpump?


 

Henry,

Yes, I see now... The pictures would be great to avoid misunderstanding. Anyway, If your cool down your baffle and walls around it, it just will work better.

Best regards,

Vladimir

On 7/24/2011 7:26 PM, henry_3507 wrote:
Vladimir,

I think you misunderstood me a little. The whole chamber which is flat in contruction but long and where the diffusionpump is connected to in one end looks like an L that is turned 90 degree clockwise so its a natural baffle by it self. There has also been made an internal oil baffle to block out even more oil vapor if needed so its pretty much a double oil baffle. However it doesnt seem like any of this has been cooled more then by convection but i might put something on to do this since it cant hurt.

Thanks for your input and help!

Regard Henry



------------------------------------