Ron,
You may have run out of aluminum during the deposition run, I have had that same problem. Are you using a shutter ?

----- Original Message -----
From: RON WHITE
Sent: Thursday, January 29, 2004 11:10 PM
Subject: Re: [VacuumX] IT WORKS :)))))))))))))))))))))))))))))

Greetings James / All,

Congratulations, interesting enough I just coated my first telescope mirror, I was waiting to open the tank when I read your post. This?was my 3rd attempt on this 8" after a couple of dozen practice successes.?There are a few?pinholes and the coating is a bit thin around the edges but all in all it looks good considering I only used 1 tungsten.?

I think I deposited a bit of tungsten over the aluminum or the aluminum foil may not be pure aluminum. ?The coating is a?very slightly?gold color?I ran the glow discharge for 10 minutes after evaporating so I may have sputtered a bit of stainless steel.

?

Any info would be greatly appreciated.

?

Next step a rotating holder. I have been playing with an ion beam source with only a little success.

?

90 minutes isn¡¯t so bad try it with a 2¡± air cooled diff pump I need close to 2 hours for a 24¡± diameter X 12¡± high tank. When I find a cheap valve I¡¯ll set up the 6¡± diff pump.

?

Dumb question # 2 is there any advantage to backing the 6¡± diff pump with the 2¡±. Is the ultimate pressure limited by the type of oil? ?Would I get significantly faster pump rate at very low pressure? If I get the ion beam source to work I¡¯ll need to suck the extra air out quicker.

?

Yea I know I don¡¯t need Ion beams but it¡¯s all for fun.

Any thoughts on a home made E-Beam? It looks easy enough.

?

Later

Ron White

James Lerch wrote:
Greetings All,

Just came in from my first evaporation attempt and everything went perfect! :)

I shot some images of the filament wiring, some more glow discharge phenomenon,
and finally an image of the system evaporating Al :)? Images available here:


Only complaint at the moment is it takes 90 minutes to evacuate the chamber!
Fortunately, this seems to make sense as the old small chamber took 10 minutes,
the new chamber is ~9 times the volume, so it takes 9 times as long to
evacuate..

On the upside I think my bottle neck is the little HVAC rough pump.? Perhaps it
is time to upgrade to a real Rough pump :)

Take Care,
James Lerch
(My telescope construction,testing, and coating site)

"Anything that can happen, will happen" -Stephen Pollock from:
"Particle Physics for Non-Physicists: A Tour of the Microcosmos"

" Press on: nothing in the world can take the place of perseverance.
Talent will not; nothing is more common than unsuccessful men with talent.
Genius will not; unrewarded genius is almost a proverb.
Education will not; the world is full of educated derelicts.
Persistence and determination alone are omnipotent. "
?????????????????????????????????????????????????????????? Calvin Coolidge


Yahoo! Groups Sponsor
ADVERTISEMENT


Yahoo! Groups Links
  • To visit your group on the web, go to:

    ?
  • To unsubscribe from this group, send an email to:
    VacuumX-unsubscribe@...
    ?
  • Your use of Yahoo! Groups is subject to the .



Yahoo! Groups Links
  • To visit your group on the web, go to:

    ?
  • To unsubscribe from this group, send an email to:
    VacuumX-unsubscribe@...
    ?
  • Your use of Yahoo! Groups is subject to the .

Join [email protected] to automatically receive all group messages.