¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: Local SYNC activated or not ?


 

Dear Gary, dear all,
"Anyway, I will redo all the test and make videos in 3 weeks:?
  • LEDs during startup?
  • up+down or CW+CCW for 3 seconds
  • press the local synch button"
Following the previous exchanges in the thread I did yesterday the above test.
* The Leds during startup seems? normal :see video "img_3622"
* up+down or Cw+CCW for 1 sec : ok, yellow led activate (and I checked later in field that yes, directions are inversed when pressing)
* press the local synch button : see the video : there is something strange? when pressing it. it stops to light after 1 sec. Note that :
? ? ? ? ? ? ? ? ? ? ? *the video was taken few seconds after? so hand pad was very near the main servocat unit.?
? ? ? ? ? ? ? ? ? ? ? * Argonavis was not started => no target selected on Argonavis => maybe this behavior of the local synch button is normal when AN not yet started ?
? ? ? ? ? ? ? ? ? ? ? * I say this because after Angonavis was put in operation, I tested the local synch function and it behaved normally
Thanks for your feedback confirming it is normal that the yellow Led turn off after 1 sec if AN not in function
Regards?
Rapha?l

Join [email protected] to automatically receive all group messages.