Re: Changing the mutual inductance coefficient of K statements with time


 

Hi John Woodgate.
In my example, there is no need to use DOT commands ".inc" and ". Lib". LTspice allows it. Link to the library name within the symbol "Winding0.asy". Just run the simulation.
Bordodynov.

17.07.2013, 20:19, "John Woodgate" <jmw@...>:

In message <20130717075502.CBBBA34B@...>, dated Wed, 17
Jul 2013, Macy <macy@...> writes:


Did a search for 'content' of files, in my case all were text files,
looking for a specific phrase. so I was looking inside *.txt for
"paramagnetic" to appear anywhere.
My problem is different. I can open Core.lib in a real text reader (not
Notepad) and see SUBCKT Winding0 there, but even with .inc core.lib
added to the schematic as a Spice directive, I still get the error
message 'Unknown subckt called in xu1 in n004....'

All files are saved to Desktop.
--
OOO - Own Opinions Only. See www.jmwa.demon.co.uk
Why is the stapler always empty just when you want it?

John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK