--- In LTspice@..., Ganesan <dg1@...> wrote:
Rick,
in this case
".options plotwinsize=0"
didn't help..
So i think it is a time step control issue..
cheers
AG
AG,
Yes, in this case that is correct, because, as I said, there are no other dynamics to limit the step size. The step time control algorithm doesn't know what to do except to limit the maximum step size to 1/50 or 1/100 (I forgot which, but it doesn't matter) of the total simulation time.
However, the only reason I took this time to send my last message was to try to explain to you that this particular case is somewhat of an exception, and that indiscriminate use of a maximum step size is not usually the best solution.
Rick