Pedro wrote:
The "PWL file" is only for monotonically increasing sources. Since mine is another simulation's export that does not happen. That's why I am using this SCOPEDATA definition.
I'm afraid that is incorrect.
?
PWL, either with or without "PWL file=", is not only for monotonically increasing sources.? Were you taught that?? ?That would be incorrect.? It is for any kind of point-by-point (piecewise linear in time) signal description.
?
(And be aware of the difference between a PWL I/V curve, and a PWL V/time description.? The PL in PLECS stands for Piecewise Linear, which I believe refers to its use of piecewise linear electrical descriptions of a device's nonlinear I/V characteristics at any instant in time.? That is not the same thing as a SPICE source that is piecewise-linear in time.)
?
SPICE/LTspice does not have the name "SCOPEDATA".? Maybe it came from a scope or from another simulation (MATLAB?), but if it is a piecewise-linear voltage/time table, then that is what it is.? You need to call it a "PWL file" to use it in LTspice.? Don't use the term "SCCOPEDATA" in LTspice.
?
By the way, I point out again that LTspice is spelled "LTspice", not "LTSpice".
?
Andy
?