There are reverse-compatibility issues with
24.1.8, but exactly which 24.1.x are you using? Issues before
x.x.8 are suspect. Are you getting errors or just warnings?
On 2025-05-23 00:04, Hawker wrote:
Howdy
I finally got around to updating from 24.0.x to 24.1.x and a lot
seems to have broken for me.
Am I correct in assuming in 24.1 you cannot have a .include to a
model you are not using?
I tend to have a "template" for a type of work where I may
define a pile of parts, but not always use them all. Up to now
that has not been an issue but now I get an error like
?
C:\Users\{user}\Documents\LTspiceXVII\lib\cmp\TL074.301(43):
Expected device instantiation or directive here.
I can change it to a comment and it works.
I am also finding some of my legacy models that came from LT
Spice no longer work. For example how can I fix this one?
It's been working fine for nearly 20 years.
C:\Users\{user}\Documents\LTspice\user.jft(1): Syntax error
(unexpected input).
.MODEL 2N5457 NJF(VTO=-1.8 BETA=0.00135 LAMBDA=0.001 RD=35
RS=31.5 + CGS=2.25E-12 CGD=6E-12 KF=6.5E-17 AF=0.5 )
? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
?? ^^^^^^^^^
--
Best wishes John Woodgate RAYLEIGH Essex OOO-Own Opinions Only
If something is true: * as far as we know - it's science *for
certain - it's mathematics *unquestionably - it's religion