Thanks for the nudge, Andy!

Yep, the give-away was that the values for Ncells was always for the last Voc step.

?

At one point, I did have voltages for Ncells/2, but thought it looked kludgy, and ¡°fixed it¡± by .meas PARAM!

?

Dave

?

From: [email protected] <[email protected]> On Behalf Of Andy I via groups.io
Sent: Wednesday, April 30, 2025 5:38 PM
To: [email protected]
Subject: EXTERNAL: Re: [LTspice] Possible g;itch in stepping parameters

?

I need to refresh my memory about this.? However, ...

?

Remember that all .MEAS commands are evaluated after all simulations are complete.? I think it means that user-defined PARAMeters hold their final values, at the last .STEP in the sequence.? Voltages and currents can be recalled from each .STEP, but parameter values can not.

?