Such errors are difficult to resolve. In this
particular case, where an ADI schematic won't run. I suggest a
report to ADI's Engineer Zone. It should run in XVII, unless ADI
say it won't.
On 2025-02-26 14:02, ehernan3 via
groups.io wrote:
I
had downloaded the MAX44241 Spice model and Ltspice
schematic from Analog's website. For some reason I get the
following error message. " Analysis: Time step too small;
initial timepoint; trouble with u1: desd-instance d:u1:3 " I
didn't change anything within the model or schematic itself
so I'm not too sure why is occurred. Please note I am
limited to use Ltspice XVII and can't update my software to
LTspice 24, due to my company not approving that version of
the software. I was wondering if there is a work around to
get that error to not show up anymore and run without any
issues within LTspice XVII.
Link:?
--
OOO - Own Opinions only
If something is true:
* as far as we know - it's science
*for certain - it's mathematics
*unquestionably - it's religion