¿ªÔÆÌåÓý

Re: Error with SW()


 

Sheeza vorke swimmingly
Thanx much Andy / peeps


On Tue, May 14, 2024 at 8:52?AM Andy I via <AI.egrps+io=[email protected]> wrote:
Al,

Open and read the Help page for voltage-controlled Switch elements.

Switches MUST use a .MODEL statement, which is a separate line on your schematic.? And the element itself is identified with the NAME of that .model, not any of its parameters.

Add this line to your schematic:

.model MySW SW(Ron=1k0 Roff=10meg Vt=1.65 Vh=100m Lser=1u Vser=0)

Then right-click on the symbol, and change its Value attribute to "MySW" (and nothing else).

I am pretty sure that is exactly what? Dave wrote, too.

Since Vser defaults to 0, you can omit it.

Andy



--
AC2CL

I do not think there is any thrill that
can go through the human heart like that felt by the inventor as
he sees some creation of the brain unfolding to success...
Such emotions make a man forget food, sleep, friends, love, everything.

- Nikola Tesla