That problem isn't in the
subcircuit, but there is a problem there. The expression for
the capacitance is wrong, as you can see because it increases
with the separation of the electrodes. The capacitance is
?o*area/distance.
The 'multiple instances'
problem is in the .ASY or .ASC or both. Have you put a
reference to the subcircuit in the .ASY as well as in the
.ASC?
======================================================================================
Best wishes
John Woodgate OOO-Own Opinions Only
Rayleigh, Essex UK
I hear, and I forget.
I see, and I remember.
I do, and I understand.
Xunzi (340 - 245 BC)
On 2023-07-03 10:15, Richard Andrews
via groups.io wrote:
toggle quoted message
Show quoted text
I made a subckt of a spark gap and linked it to an edited neonbulb
symbol and now I get the warning "multiple instances of
"C:U2:spark"". Please help me straighten this out.