2025-03-25 20:22:08.824 > ? ?RadioFreq + theAdjustment ?= -0.01
2025-03-25 20:22:08.824 > CIVModule.SetXcvrFreq: NewFreq = -0.01, ?theBand = -1, ?QSYBand = -1
2025-03-25 20:22:08.824 > CIVModule.EnqueueXcvrCmd: Command = Wait
2025-03-25 20:22:08.832 > CIVModule.GetRadioSMeter: True
2025-03-25 20:22:08.841 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Frequency, count = 10
2025-03-25 20:22:08.842 > ? ?response timeout Request Frequency
2025-03-25 20:22:08.842 > CIVModule.ExecuteNextXcvrCmd: 10 [Request Frequency] F = 0, M = 0, A = 0, A2 = 0
2025-03-25 20:22:08.843 > CIVModule.RequestFrequency
2025-03-25 20:22:09.048 > CIVModule.ExecuteNextXcvrCmd: 18 [Wait] F = 0, M = 0, A = 0, A2 = 0
2025-03-25 20:22:09.253 > CIVModule.PollXcvr, Idle Mode = 9, PollCount = 12
2025-03-25 20:22:09.253 > CIVModule.RequestFrequency
2025-03-25 20:22:09.447 > CIVModule.PollXcvr, Idle Mode = 10, PollCount = 12
2025-03-25 20:22:09.448 > CIVModule.SendCommand: ?FE ?FE ?6A ?E0 ?1A ? 6 ?FD ?
2025-03-25 20:22:09.653 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 1
2025-03-25 20:22:09.827 > CIVModule.EnqueueXcvrCmd: Command = Wait
2025-03-25 20:22:09.828 > CIVModule.EnqueueXcvrCmd: Command = Request Frequency
2025-03-25 20:22:09.828 > CIVModule.EnqueueXcvrCmd: Command = Wait
2025-03-25 20:22:09.829 > CIVModule.EnqueueXcvrCmd: Command = Request Mode
2025-03-25 20:22:09.859 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 2
2025-03-25 20:22:10.065 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 3
2025-03-25 20:22:10.269 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 4
2025-03-25 20:22:10.467 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 5
2025-03-25 20:22:10.667 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 6
2025-03-25 20:22:10.871 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 7
2025-03-25 20:22:11.086 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 8
2025-03-25 20:22:11.286 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 9
2025-03-25 20:22:11.480 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Data Submode, count = 10
2025-03-25 20:22:11.481 > ? ?response timeout Request Data Submode
2025-03-25 20:22:11.481 > CIVModule.ExecuteNextXcvrCmd: 18 [Wait] F = 0, M = 0, A = 0, A2 = 0
2025-03-25 20:22:11.684 > CIVModule.ExecuteNextXcvrCmd: 10 [Request Frequency] F = 0, M = 0, A = 0, A2 = 0
2025-03-25 20:22:11.684 > CIVModule.RequestFrequency
2025-03-25 20:22:11.685 > CIVModule.SendCommand: ?FE ?FE ?6A ?E0 ? 3 ?FD ?
2025-03-25 20:22:11.886 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Frequency, count = 1
2025-03-25 20:22:12.103 > CIVModule.ExecuteNextXcvrCmd awaiting response from Request Frequency, count = 2
2025-03-25 20:22:12.294 > CIVModule.ExecuteNextXcvrCmd awaiting respo
?
These are the errors showing up-hope this makes sense.
+ Those aren't error reports, those are diagnostics reported when you enable "Log debugging info". They indicate that Commander is not receiving responses from your IC-7800.