Re: Is R&L electronics still the place to get a real NanoVNA H4?
Go to the Nano VNA Wikki, there you will find all the buying info you need, but hurry, as of Feb 4 goods made in China are going to cost you a minimum of 10% more. [email protected]> wrote:
By
John
·
#39303
·
|
Re: Is R&L electronics still the place to get a real NanoVNA H4?
I bought my H4 and TinySA Ultra from R&L after many recommendations from here.
By
Brian Wall
·
#39302
·
|
Is R&L electronics still the place to get a real NanoVNA H4?
My NanoVNA H4 is not operating properly, I'm about to buy a new one. Is R&L the place to get a real model? Mikek
By
Mikek
·
#39301
·
|
I added entity shortcuts to my nanovna
With the ADC detection button, you can set multiple shortcut keys, such as entering DFU mode, taking screenshots, pausing scanning, and so on. Because of these menus, I need to click several times to
By
blackberryer
·
#39300
·
|
Re: Stimulus Span change a bit the Smith measurement
I recommend to you to use the resonance method, it¡¯s more accurate. You are using a very simple VNA and there are errors of measurement bigger than the magnitude or real part of Z. I posted a method
By
Patricio Greco
·
#39299
·
|
Re: Stimulus Span change a bit the Smith measurement
Hi All, For those who have the excellent book 'Experimental Methods in RF Design' (Wes Hayward W7ZO! et al.) look at the following section. 7.9 Q measurement of LC resonators. The test jig described
By
Philip Stevens
·
#39297
·
|
Re: NanoVNA / SAA-2N ver/v2-2
I have the F V2 and it is everything a person could ask for except the inclusion of and SD Card and lacking of Dynamic Range for filter measurement. For working with antennas is simple and allows a
By
VE6LX
·
#39296
·
|
Re: Stimulus Span change a bit the Smith measurement
Hi All excuse me , i just doing the calibration again at the same time of the two different stimulus span , and remeasure the same inductor , and i have the same value of resistor loss , so the issue
By
Team-SIM SIM-Mode
·
#39295
·
|
Re: Stimulus Span change a bit the Smith measurement
Hi Thanks Roger and all contributers for their interesting comments , i am agree of almost all , it is true that making measurements of the low resistances of the inductances with the 50 Ohm divider
By
Team-SIM SIM-Mode
·
#39294
·
|
Re: test board, how to use
Thank's for all replies. 73 Math/PA3GDS
By
Pa3gds@...
·
#39293
·
|
Locked
Re: Owen Duffys blog closed
Yes, I am going to lock this thread since it is far off topic. I think we've discussed this matter sufficiently. DaveD, co-owner KC0WJN [email protected]> wrote:
By
Dave Daniel
·
#39292
·
|
Locked
Re: Owen Duffys blog closed
Thank you Steve! 73, and thanks, Dave (NK7Z) https://www.nk7z.net ARRL Volunteer Examiner ARRL Technical Specialist, RFI ARRL Asst. Director, NW Division, Technical Resources
By
Dave (NK7Z)
·
#39291
·
|
Locked
Re: Owen Duffys blog closed
Edit...I did the same
By
Geoff Peters - AB6BT
·
#39290
·
|
Locked
Re: Owen Duffys blog closed
Thanks Steve!
By
Geoff Peters - AB6BT
·
#39289
·
|
Locked
Re: Owen Duffys blog closed
I have, reluctantly, muted this group for the time being. Discussion about the morality or legality of absconding someone else's work are not why I joined.
By
Steve, N5TIN
·
#39288
·
|
Re: NanoVNA / SAA-2N ver/v2-2
Try removing and re-seating the display cable. Mine showed a white screen (gave me a mini heart attack) but re-seating the cable restored normal operation. Best regards, Don Brant
By
Donald S Brant Jr
·
#39287
·
|
Re: Stimulus Span change a bit the Smith measurement
OK, glad that's cleared up. I thought I must have done something really wrong to get 4 times the value you reported. I hope Nizar got his answer. I think the best one was provided by Jim Lux. It
By
Brian Beezley
·
#39286
·
|
Re: Stimulus Span change a bit the Smith measurement
Brian, You are indeed correct. The Q calculation is wrong. I ran the simulation at https://miguelvaca.github.io/vk3cpu/toroid.html I will let the author know... Roger Roger
By
Roger Need
·
#39285
·
|
Re: Stimulus Span change a bit the Smith measurement
Roger, I think there is something wrong with your Q calculation. Using your X and R, Q = 17.1 / 0.0935 = 183, close to what I measure, although I measure a higher inductance. Brian
By
Brian Beezley
·
#39284
·
|
Re: Stimulus Span change a bit the Smith measurement
There can be some variation in production batches. Amidon does not make their own cores - they buy them from suppliers like Micrometals and Fair_rite. The wire diameter and how you wind can affect
By
Roger Need
·
#39283
·
|