Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, Well, I said problem solved, but I flashed Firmware 0.8.4.4 (Built 27/04/2020 -21:32:13) again,? calibrated NanoVNA standalone 10kHz to 2.7 GHz and calibrated NanoVNA-Saver 290MHz to 320
By
Jos Stevens
·
#12985
·
|
Re: OT: looking for testers for a tiny handheld spectrum alayzer
I'd be interested , I have a DSP Receiver which also has people working on a spectrum analyzer program for it which I've been playing with. It, however it has to be tired to a computer to use it.
By
PhilKE3FL
·
#12984
·
|
Re: OT: looking for testers for a tiny handheld spectrum alayzer
Hi Erik, I am retired and already participating in firmware evaluation and testing for the OpenGD77 project. This is a project putting hotspot MMDVM code and replacement firmware inside a GD77
By
Marc Erickson KD2LH
·
#12983
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, I reinstalled NanoVNA-Saver, left the firmware as it was (previous working) and calibrated in NanoVNA-Saver, same problem. After this I realized that while calibrating 2 port I had CH1 loaded
By
Jos Stevens
·
#12982
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, I flashed the previous firmware (Built Apr 25-2020 -23:08:04) that worked well for me before and now it behaves the same as the later firmwares, so probably something has changed in my
By
Jos Stevens
·
#12981
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, This morning I started using the NanoVNA-H4 loaded with your firmware number 3 as yesterday. . 1) Started NanoVNA-Saver. 2) Did a reset in "calibration". 3) Did a full calibration (2 port).
By
Jos Stevens
·
#12980
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, Don't understand either, I always do reset before calibration. Will flash the previous working firmware again today to check if it still works. Jos Op 27-4-2020 om 23:44 schreef DiSlord:
By
Jos Stevens
·
#12979
·
|
Re: How much calibration is enough?
#calibration
I have made a *table* to better see what is the result of the measurements from the PDF file. Calibration MHz Scan MHz SWR RL dB 0.05 - 900 1 - 30 1.20 20.56 1 - 30 1 - 30 1.19 21.12 0.05 - 900 13 -
By
Rudi
·
#12978
·
|
Re: How much calibration is enough?
#calibration
I have made a table to better see what is the result of the measurements from the PDF file. For my understanding here the *precision of the frequency* is important. Calibration MHz Scan MHz Step KHz
By
Rudi
·
#12977
·
|
Re: OT: looking for testers for a tiny handheld spectrum alayzer
Not sure yet. Target is comparable to one of the nanoVNA family -- NanoVNA Wiki: /g/nanovna-users/wiki/home NanoVNA Files: /g/nanovna-users/files Erik, PD0EK
By
Erik Kaashoek
·
#12976
·
|
Re: OT: looking for testers for a tiny handheld spectrum alayzer
If you really still need testers, I might be able to contribute. For my day job, I use an HP3585A for phase noise measurements.? Impressive dynamic range on that tank. Also a Rigol for field
By
Terry Bullett
·
#12975
·
|
Re: OT: looking for testers for a tiny handheld spectrum alayzer
This very timely as I have spent the last couple of days looking at Spectrum analyzers to replace my old CTE one. -- Terry VK5TM https://www.vk5tm.com ( https://vk5tm.com )
By
Terry VK5TM
·
#12974
·
|
Re: SWR with a NanoVNA
Dave is correct. The VSWR doesn't vary along the transmission line except for a small variation due to loss of the transmission line. If you do see the VSWR vary, that indicates imbalance on the
By
Carey Fisher
·
#12973
·
|
Re: Up-grading the -F model...
On Mon, Apr 27, 2020 at 03:16 PM, Eric Furness wrote: I Upgraded to 0.1.1 All worked ok. How do you get to the TDR function? ===================================================== DISPLAY->TRANSFORM
By
hwalker
·
#12972
·
|
Re: Up-grading the -F model...
By
Eric Furness <ericfurn1@...>
·
#12971
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
Only if have problem, if you get correct result, not need do it. Recalibrate need if threshold value change (possible not correct calibration point near harmonic change)
By
DiSlord
·
#12970
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
On Mon, Apr 27, 2020 at 01:18 PM, DiSlord wrote: Please not use old calibration, recalibrate after update ========================================= DiSlord, I haven't had any issues with 0.8.4.3 or
By
hwalker
·
#12969
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, Flashed number 3, calibrated NanoVNA-Saver, measured S21 and 49.85 standard see the pictures. Call it a day for now. Jos Op 27-4-2020 om 22:18 schreef DiSlord:
By
Jos Stevens
·
#12968
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
i don`t understand 1 variant is last firmware 2 variant - is 0.8.4.3 (Only 8kHz IF change) 3 variant - is old 0.8.4.4 (2x external freq) You not fogot reset self NanoVNA calibration before calibrate
By
DiSlord
·
#12967
·
|
Re: NanoVNA firmvare, compiled by DiSlord
#firmware
DiSlord, Flashed number 2,? threshold set to 300MHz,? recalibrated NanoVNA-Saver,? S21 at 0 now,? R+jX? R still not shown, S11 49.85 Ohms standard? way off , Marker 1 an 3 not shown. See
By
Jos Stevens
·
#12966
·
|