Re: Saver with Win7
Thanks for the suggestion, Bryan. It sounds interesting. Do you know if/how
group delay is determined from S-parameters? I'm not really an RF engineer, so I have had to figure out all these things from the ground up ;-) (Also, no more busy than I can easily answer emails. :-) -- Rune / 5Q5R On Wed, 25 Sep 2019 at 16:17, bryburns via Groups.Io <bryburns= [email protected]> wrote: peter_pc2a |
Re: Saver with Win7
peter_pc2a
I am running nanovna-saver.v0.0.11 on Win 7 - 64 bit and it is working great. The software is very useful and seems to be quite stable. Rune: I know you are quite busy. Here is a suggestion: I would like to see group delay added to the measurements. Thanks, again, for all of your great work. -- Bryan, WA5VAH |
Re: Saver with Win7
Using Thunderbird, and perhaps other email clients, you should see the poster's full email address on the "From" line at the top of the email header. For instance, when I look at your email (to which I am replying here), I see k4tql@....
toggle quoted message
Show quoted text
One can right-click on the email address and copy it. DaveD On 9/25/2019 9:50 AM, BruceN wrote:
A bit off topic, perhaps, but tell me, how do I expand an email address like mihtjel@... ? |
Re: Saver with Win7
Hi Bruce,
toggle quoted message
Show quoted text
I'm not certain quite how it works via groups.io, but I did attempt to put my email (mihtjel@...) in the body of the email I sent earlier, in order that Peter (and others) could contact me directly, should they need to. I should probably set up an official email address for nanovna-saver at some point, given the number of users it's starting to accrue, but for now, gmail is doing fine at sorting them for me. ;-) -- Rune On Wed, 25 Sep 2019 at 15:50, BruceN <k4tql@...> wrote:
A bit off topic, perhaps, but tell me, how do I expand an email address |
Re: Firmware font size - 2 versus 4 trace
Indeed, larger fonts need more memory. Prefer to spend memory on more useful features. Suggest to buy small reading glasses. I did.....
Hugen does not have the large font size version on github (I can not find it) and I'm using the edy555 version as a starting point |
Re: Firmware font size - 2 versus 4 trace
Erik,
toggle quoted message
Show quoted text
Is there enough firmware space on the uP for one more firmware on-screen option to display either 2 larger or 4 smaller traces? I think that would be a nice option to have. I know Hugen's firmware for the 2 trace version was quite a bit larger in size though. Thanks, Larry On Wed, Sep 25, 2019 at 08:24 AM, Bruce KX4AZ wrote:
|
Firmware font size - 2 versus 4 trace
I like the new 1500 MHz firmware - but I do miss the larger font size of the original 2 trace "antenna analyzer" version my nanoVNA shipped with. Wondering if there is some inherent reason why the larger font can't be used with 4 trace firmware, other than the screen getting too crowded with text.
|
Re: errors of "error" models
@yza
As I am not scientifically trained I have great difficulty to follow your posts and to understand what it is you ask. - Are you merely sharing knowledge on error models applicable to VNA? Great, need some help on how we can use your knowledge to understand the limitations of our own measurements - Do you invite only those with a solid scientific background to participate in an performance evaluation of the nanoVNA? Excellent, let the experts join and deliver a solid foundation to understand the limitations of nanoVNA performance - Do you want the wider group to participate? If so, in what way? How to contribute? Please help me to understand. |
Re: NanoVNA Saver
Rune,
Wanted to add my thanks for all the work you have done with the software, and I really appreciate the features added to the latest version. I've never been able to do a calibration within the software, no doubt I am doing something wrong with the key sequence. Calibration works fine with the touch screen, so not really an issue...but I do wonder if someone has ever written a calibration "tutorial" about how it is done in the NanoVNA Saver software. 73, Bruce |
Re: on the comparisons
Hi David
I have noted your comment. As far as I know many are using Linux as platform. Look in the Yahoo Forum for details and probably also in the help file which exist as pdf. Regarding licensing I know people are invited to used the VNWA and the embedded VNWA Virtual Demo Device where you can run the software just like if you had a connected VNWA hardware. This to facilitate a potential customer to a VNWA can try it out prior a decision to purchase. The only detail is that you do not enter a license code but just carry on with the installation, so I find it hard you are right on "only licensed for use with the VNWA". It supports also the N2PK VNA so that is another indication it is not linked to the use of the VNWA. There might be some remark in the licensing screen during installation with a precise definition about this issue (it is a long time since I read it). Why focus on the negative sides be positive please ? Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af Dr. David Kirkby from Kirkby Microwave Ltd Sendt: 25. september 2019 01:19 Til: [email protected] Emne: Re: [nanovna-users] on the comparisons On Tue, 24 Sep 2019 at 10:22, Kurt Poulsen <kurt@...> wrote: Hi David Kurt, There are a few issues here 1) VNWA software is closed source. 2) VNWA software only runs on Windows 3) Although the VNWA software is free, the last time I looked it was only licensed for use with the VNWA. I know Tom has never pressed this, and in fact once Tom made a change that allowed me to read in S-parameters from my LCR meter, although the VNWA software doesn¡¯t fully support the Touchstone file format. I would add the same is true of an Agilent PNA-X ????. Sonnet Lite was a free, but closed source application which has better support for Touchstone files. As an advocate of open source software, and as someone who has a dislike for Windows, I would rather an open source solution I can run on a Unix or Linux system. Dave --Dr. David Kirkby, Kirkby Microwave Ltd, drkirkby@... Telephone 01621-680100./ +44 1621 680100 Registered in England & Wales, company number 08914892. Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, Chelmsford, Essex, CM3 6DT, United Kingdom |
Re: on the comparisons
Hi Erik
Ok, thank you. I have updated the Excell Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af erik@... Sendt: 25. september 2019 10:24 Til: [email protected] Emne: Re: [nanovna-users] on the comparisons Kurt, Made some small changes Input tab: Paste your rectangular input file of max 1001 points directly into this tab. Check if the values are correctly spread over the columns like is shown now. If they are all in the first column use data->columns with space as delimiter to spread over the columns Calculation tab: This is where the complex values and the t-check formula are calculated . The graph will show the outcome |
Re: errors of "error" models
Hello,
Allow us, please, to insist staying on the subject by transferring and repeating here the contents of the following messages, in order to somehow protect -if not save- them [*] - - - - - 4 : on the comparison - /g/nanovna-users/message/2913 Hello, Allow us, please, to point out that to be possible to the slightest a comparison between measurements regarding nanovna and/or vna, these measurements should be accompanied by an estimation of their uncertainty, as well as by a clearly stated way of its calculation. Sincerely, yin@pez@arg - - - - - 5 : Re: on the comparison - /g/nanovna-users/message/2943 Hello, We both thank you very much all of you for your most valuable comments ! We gladly feel that we find a sound ground for a fruitful discussion, as we hope. Well, we don't mean to offend you but, in our humble opinion, the whole story of hp "error" models is just a myth serving the powerful advertisement, so, we don't believe at all that this matter is due to any lack of knowledge or of ability among Radio Amateurs, while, in direct contrast to that, the pioneered Work of whom is usually exploited by patentees. Anyway, we just ask you now to be patient enough and give us the chance to present you: (1) the fortran code by which we estimate the errors of the aforementioned "errors", in full one-port vna measurements (see, please, the related "discussion" [1]), as well as (2) sometime later, the way in which we calculate the errors of the corresponding "errors" in full two-port vna measurements. Finally, we just mention that in the case of nanovna we just took a look at the mathematical expressions included there and we have a feeling -but notice, please, NOT a proof yet- that the "error" model(s) used in the original nanovna code are missing some terms which are present in the original "error" model(s). And this is the reason that we already asked: "if is there any certain knowledge available regarding the specific error model(s) that NanoVNA uses" [2] --but unfortunately without any response yet--so, we did not be able to comment our vna-nanovna comparison results [3], and by the way: after we followed, almost fully, the suggestions given in the Excellent Work of Larry Rothman [4]. Sincerely, yin&pez@arg [1] errors of "error" models /g/nanovna-users/message/2770 Saturday, September 21, 2019 04:10 [2] error model(s) /g/nanovna-users/message/2553 Wednesday, September 18, 2019 00:24 [3] vna ~ nanovna : (r,x) comparative results but no comments /g/nanovna-users/message/2521 Tuesday, September 17, 2019 02:31 [4] Re: List of NanoVNA Console Commands /g/nanovna-users/message/2457 Sunday, September 15, 2019 15:23 - - - - - 6 : Re: on the comparison - /g/nanovna-users/message/2968 Hello, Allow us, please, to summarize briefly: (0) The measurement uncertainty is error-bounds of the measurement. (1) If a measurement does not involve mathematical expressions then someone can choose the statistical way he likes to mathematically estimate|compute a subjective uncertainty . (2) If a measurement involves known mathematical expressions then either there is or there is not -up to now- a known, unique, mathematical way, that is a way solely based on these mathematical expressions alone, to estimate|compute an objective uncertainty. (3) A vna measurement involves known mathematical expressions and after more than ten 10 years there are now five 5 known mathematical ways to estimate|compute a unique objective uncertainty, each one for each of the five 5 "error" models considered (by intermediately estimate|compute the errors of these "errors"), as well as new one(s), the sixth 6th (or more), shall be added as soon as the "error" model(s) of the NanoVNA will be revealed. (4) These "errors" of "error" models are just historical names of parameters mathematically expressed in terms to what is widely known today collectively as "S-parameters" and thus these are not error bounds - they are not uncertainties of the measurement. Sincerely, yin&pez@arg [ * [ which -unfortunately enough, but not unexpectedly in almost any [ suffering public discussion- were interfered elsewhere, as usually, [ that is using the well-known technique of the coordinated barrage [ of disorienting, non-answering, non-participating, non-discussing [ cries - that is, once more : business, as usual Sincerely, yin&pez@arg 8 |
Re: on the comparisons
Kurt,
Made some small changes Input tab: Paste your rectangular input file of max 1001 points directly into this tab. Check if the values are correctly spread over the columns like is shown now. If they are all in the first column use data->columns with space as delimiter to spread over the columns Calculation tab: This is where the complex values and the t-check formula are calculated . The graph will show the outcome |
Re: Saver with Win7
Hi Peter,
I missed the SP1 service pack under win7 32bit and also needed Ms VC ++. Without them I couldn't start. Unfortunately for some reason I could only install SP1 with an integrated installer with a full system installation, but now everything works fine. Good luck in debugging. 73&dx: Gyula |
Re: Saver with Win7
peter_pc2a
No Virus protection is on, so must be something different
toggle quoted message
Show quoted text
Peter Op 25-9-2019 om 9:05 schreef uni berry: Try to turn off antivirus protection. Mine have a same problem, |
Re: Saver with Win7
Hi Peter,
toggle quoted message
Show quoted text
thanks for trying at least :-) If you're running the latest release (if not, you should be ;-), please do try to use the command line option "-D logfile.txt" This will log all debugging information to the file name you specify. You can then try sending the log file to me after a crash/lockup, and I will try to see if I can figure out what's going wrong. If you're the curious type, and want to follow along with the debugging, "-d" outputs log information to the console. My email is mihtjel@... if you want to send me a log file. I hope you get it working! -- Rune / 5Q5R On Wed, 25 Sep 2019 at 08:54, peter_pc2a <pc2a@...> wrote:
Hi |
Re: Saver with Win7
Try to turn off antivirus protection. Mine have a same problem,
toggle quoted message
Show quoted text
working fine on Windows 10 but hanging when running on windows 7. Turn it off kapersky antivirus protection then solve the problem. Regards On Wed, Sep 25, 2019, 14:54 peter_pc2a <pc2a@...> wrote:
Hi |
yeah pc sees it
The original one went back as there really was too much wrong with it.
The new one... so much better quality. Bought in UK from a UK source too In case anyone asks. :-) PC sees it and seems to be operatiing fine. [ 518.613594] usb 2-2.1: new full-speed USB device number 4 using ehci-pci [ 518.722961] usb 2-2.1: New USB device found, idVendor=0483, idProduct=5740 [ 518.722963] usb 2-2.1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 [ 518.722964] usb 2-2.1: Product: ChibiOS/RT Virtual COM Port [ 518.722965] usb 2-2.1: Manufacturer: STMicroelectronics [ 518.722966] usb 2-2.1: SerialNumber: 400 [ 519.408580] cdc_acm 2-2.1:1.0: ttyACM0: USB ACM device [ 519.409436] usbcore: registered new interface driver cdc_acm [ 519.409437] cdc_acm: USB Abstract Control Model driver for USB modems and ISDN adapters dom@dom-usbboot:~/nanovna-saver$ lsusb Bus 002 Device 004: ID 0483:5740 STMicroelectronics STM32F407 72 Dom M1KTA |