Re: Connecting to NanoVNA "H" with Putty
#consolecommands
On Mon, May 16, 2022 at 11:33 AM, k6whp wrote:
I am using PuTTY to connect and having no success. It has been set up as aI believe you are using WIN 7. The problem could be that you do not have the correct driver installed for Windows 7. Windows 10 has the correct driver for the NanoVNA ready to go (or update will install it). With WIN 7/8/8.1 you have to manually install it. After you do Device Manager will look like the attached screenshot. Note the description of the driver... Here is a link to the WIN 7 and WIN 8 drivers for the NanoVNA on my Box drive. Download button in upper right hand corner. (Note: These are NOT the DFU drivers required for updating firmware) Roger |
Re: NanoVNA App - Installation and Use
#applications
Try 115,200 for the baud rate.
toggle quoted message
Show quoted text
73 Stan KM4HQE On 5/16/22 17:43, k6whp wrote:
Roger, |
Re: NanoVNA App - Installation and Use
#applications
Please show us the list of COM ports listed in the Windows 7 Device Manager
toggle quoted message
Show quoted text
after plugging in the nanovna. It may assign a different number than you expect. On Mon, May 16, 2022, 3:44 PM k6whp <k6whp@...> wrote:
Roger, |
Re: NanoVNA App - Installation and Use
#applications
Roger,
Appreciate your assistance. Well, it seems that my COM10 port./driver has disappeared and only COM1, COM2, and LPT1 were left behind. I followed your link to the Box validation, obtained an ID and proceeded to download the driver package. I attempted to install the drivers per the two wizards and yet the Drivers remain the same. PuTTY does not produce the previous error but instead displays a session that does not respond. Wonder what I am doing wrong? I attached some screen scrapes essentially tracking what I did. -- William, k6whp -------------------- "Cheer up, things could get worse. So I cheered up and things got worse." ![]()
NanoVNA Driver Installation.jpg
![]()
NanoVNA Driver Installation complete.jpg
![]()
NanoVNA COM1 _ COM2 Drivers.jpg
![]()
NanoVNA serial details.jpg
![]()
NanoVNA Serial session.jpg
![]()
NanoVNA Serial window.jpg
|
Re: NanoVNA App - Installation and Use
#applications
On Mon, May 16, 2022 at 02:04 PM, Roger Need wrote:
I believe you are using WIN 7. The problem could be that you do not have theHere is a link to the WIN 7 and WIN 8 drivers for the NanoVNA on my Box drive. Download button in upper right hand corner. (Note: These are NOT the DFU drivers required for updating firmware) Roger |
Re: NanoVNA App - Installation and Use
#applications
On Mon, May 16, 2022 at 01:41 PM, k6whp wrote:
NanoVNA app is not seeing your COM10 from the NanoVNA. I think you reported this with Putty as well. I suspect Saver will have the same issue. I believe you are using WIN 7. The problem could be that you do not have the correct driver installed for Windows 7. Windows 10 has the correct driver for the NanoVNA ready to go (or update will install it). With WIN 7/8/8.1 you have to manually install it. After you do Device Manager will look like the attached screenshot. Note the description of the driver... Look in this groups Wiki for WIN 7 driver details. Roger |
Re: NanoVNA App - Installation and Use
#applications
"You select the COM port from the drop down list..."
OK..how about this? (See attached.) -- William, k6whp -------------------- "Cheer up, things could get worse. So I cheered up and things got worse." |
Re: NanoVNA App - Installation and Use
#applications
If you use the latest publicly available version of the DiSlord NanoVNA-D v1.1.00 firmware and calibrate in the NanoVNA-App-v1.1.209-OD10 it will use "raw data" from the NanoVNA. That means that calibration is independent of any calibration done on the NanoVNA itself. This is a nice step up in calibration from that done in NanoVNA Saver.
Owen Duffy describes it in further detail in a blog post >> |
Re: NanoVNA App - Installation and Use
#applications
If you want to use NanoVNA app you have to be using a recent version of the firmware (last year or so). The reason is that NanoVNA app uses the binary (not ASII) transfer protocol to transfer data.
If you try to use old firmware it will connect but the app will not do sweeps. Roger |
Re: NanoVNA App - Installation and Use
#applications
On Mon, May 16, 2022 at 11:40 AM, k6whp wrote:
You select the COM port from the drop down list. Then press button below to Connect. You need to select where calibration is done from the drop down list. You can transfer Stimulus range settings from NanoVNA to app by pressing button on left. Attached screenshot shows where to click... Roger |
Re: NanoVNA App - Installation and Use
#applications
Yes indeed, thank you. Stunning app.
How does one specify COM10 -- which is what my NanoVNA uses? -- William, k6whp -------------------- "Cheer up, things could get worse. So I cheered up and things got worse." |
Connecting to NanoVNA "H" with Putty
#consolecommands
..well, figured out how to flash the firmware with the app and, thanks to help here, I was able to do a cal first in order to make the new firmware retain the config I set up. My original goal is to brighten up the faint grid lines and am given to understand that this can be done via console commands in lieu of the missing "BRIGHTNESS" option on previous firmware.
I am using PuTTY to connect and having no success. It has been set up as a serial connection to COM10 (checked with my Windows 7 device manager) and the parameters are the same the as the app parms (shown in the attachments below). Each time I attempt to open the connection I get the missing file error message per the error message attached Appreciate any help. -- William, k6whp -------------------- "Cheer up, things could get worse. So I cheered up and things got worse." |
Re: NanoVNA App - Installation and Use
#applications
Thanks, Roger!
toggle quoted message
Show quoted text
?n lun., 16 mai 2022 la 19:29, Roger Need via groups.io <sailtamarack= [email protected]> a scris: A very useful PC application for the NanoVNA was developed by One Of |
NanoVNA App - Installation and Use
#applications
A very useful PC application for the NanoVNA was developed by One Of Eleven as an alternative to NanoVNA Saver and other earlier programs. It was originally done for personal use but was kindly offered to the community. After development was stopped by the author the source code was released so that improvements could be done by others.
The program is easy to use and has many nice features... - Multiple graphing options and flexible scaling options. - Calibration works reliably and includes averaging and smoothing options - Built in firmware uploading tool that is easy to use - Continuous run mode which is useful for tuning filters and antennas - Four memories that can be used to compare results in the graphs - Export and Import of Touchstone files (s1p and s2p) - Multiple marker capability with various display options. DiSlord and Owen Duffy have made several recent improvements and bug fixes. The updated program can be downloaded here >> The program is mouse driven and by right clicking on any graph you can change the tiling options (# of graphs on screen) and the type of graph (SWR, RL, Reactance, Smith etc.). Please post any questions about how to use the program in this topic. Roger |
Re: Erratic touch screen
Your unit is a NanoVNA-F model. Try sending your query to this Groups IO
[email protected] *Clyde K. Spencer* On Mon, May 16, 2022 at 10:14 AM Team-SIM SIM-Mode via groups.io <sim31_team@...> wrote: Here is My attached Photo |
Re: New to flashing firmware.
It may be that a calibration is not stored in memory 0, so when the unit starts, it starts uncalibrated, and that could cause a display with a lot of unusual activity.
Could also be that the device is using the wrong clock chip mode. There are 2 versions, and if you have an earlier hardware platform (sounds as if you do), then you should be running the Si MODE. (look on the back of the nVNA. if it has _MS in the model, you have an MS device; else you have an Si device) Go to EXPERT SETTINGS, and confirm that the button says Si----. If it says MS----, tap it and change it. Then do a cal over some range...I usually do 50k-900M, and store that in location zero. that way when the device start, it will use a calibration. -- ~R~ 72/73 de Rich NE1EE The Dusty Key On the banks of the Piscataqua |
Re: Saver 0.4.x, startup reconfigures -H4
On 2022-05-15 18:12:-0700, you wrote:
I replied to your post on this issue a few days ago but you did not reply. Did you see my post?Yep. Del the ini file. "In order to get faster sweeps the display was frozen on the NanoVNA" I guess I have a second or two here and there... ;-) I am not bothered by sweep speed. I appreciate faster anything (almost ;-), but the H4 on bandwidth 100 is not too slow for me. 'Course I guess if I were spending hours with it, I'd appreciate any speedup.... Jim Lux mentioned editing the ini file, which had not occurred to me...I'll look into that. |