Re: Calibration procedure
Bill, I wrote up a calibration sequence in an earlier thread. If you cannot find it, I will cut and paste in a reply. Currently this was done on the 2 -track unit but I assume the sequence is no different for the 4 track.
Key is the flow on the unit has you go to DONE and causes you to omit SHORT and OPEN. Alan W4AMV |
Calibration procedure
Would someone be willing to publish a pictorial description of the calibration process.
I have read thru the English version of the manual (no photos of the Cal process at all) and am unclear how I should calibrate for a two port filter measurement. In fact, if someone could show a two port measurement being made, that would be awesome. Tell you what, if someone illustrates the Cal process, I will publish a two port measurement of an LC low pass Butterworth filter... Thanks, Bill |
Re: USPS mis-delivery of nanova package - to wrong zip and STATE! Scam or error?
Still waiting for my nanovna, but bogus USPS tracking is not at all amazing.
I have had packages wrongly reported delivery to my correct address up to 4 days before actual delivery. If you have tracking data from a successful delivery for comparison, you may note where bogus track has missing steps. I suppose these result from wrong barcode scans... |
USPS mis-delivery of nanova package - to wrong zip and STATE! Scam or error?
I live in Ohio. My nanovna package tracking shows delivery to "Mailbox" in Nebraska on Saturday.
USPS "Email Us" site is "temporarily unavailable" and their phone tree is a complete FAIL. I think this is not likely the eBay seller's fault, but an amazing USPS error, since tracking is present. Scam or error? Anyone with advice or comments? Thanks, AC8FD |
Re: Translated instructions
On Sat, Jun 29, 2019 at 08:40 PM, Larry Rothman wrote:
You can store the touch calibration us saveconfig command. |
Re: Translated instructions
Great and good luck. Have Fun. Best 73' Alan
________________________________ From: [email protected] <[email protected]> on behalf of Nuno <Nmbb77@...> Sent: Sunday, June 30, 2019 7:14 PM To: [email protected] Subject: Re: [nanovna-users] Translated instructions Workedine. Thanks. Now I can make some tests on some handheld antenas. And in a 4m antenna that was about to build. Best 73 |
nanoVNA as an AA
Works very nice. Just measured a NVIS antenna on 40 meters. Spot on with other devices. Suggest putting unit in a black box unless the Sun is hidden by a cloud.
For the HF band, suggest store pre cal freq segments to improve resolution. I use 3-10 MHz and 7-21 MHz as examples, that way easy to see the SWR null if one exists. Alan W4AMV |
Re: Translated instructions
On the calibrate, the firmware routine does not appear quite right.
In any case, what I found that works consistent is the following: 1. Select stimulus and start and stop frequency 2. Select CAL and then CALIBRATE 3. Connect the 50 ohm to CH0 4. Press LOAD and then PRESS ISOLN (Note these are highlighted in black at first and then ISOLN goes green) 5. Then connect a THRU cable form CH0 to CH1 and press THRU 6. The firmware takes you to DONE. IGNORE!!!! 7. Now connect an OPEN to CH0 8. Press OPEN 9. Connect a SHORT to CH0 10. Press SHORT 11. Then finally press DONE 12. And SAVE That's it. Check and be sure that the open, short and 50 ohm are on the proper side of the chart. Alan W4AMV P.S. Let me know if not clear or if I missed something. NOTE, this is for the 2 trace or 2 track VNA. Not the 4 track or S11/S21 measurement device. Although I suspect the cal routine is no different. ________________________________ From: [email protected] <[email protected]> on behalf of Nmbb77@... <Nmbb77@...> Sent: Sunday, June 30, 2019 1:29 PM To: [email protected] Subject: Re: [nanovna-users] Translated instructions Hello all. I have the same instructions, plan to do someday in Portuguese. At time the most confused part is the calibration, didn¡¯T figure yet if it take long to stabilize, if its like put open, short and load and press calibrate... 73¡¯²õ CT1JQJ |
Re: Translated instructions
Thanks Larry, good info. Alan
________________________________ From: [email protected] <[email protected]> on behalf of Larry Rothman <ac293@...> Sent: Saturday, June 29, 2019 12:40 PM To: [email protected] Subject: Re: [nanovna-users] Translated instructions You can access additional commands by connecting the unit to your PC, opening a terminal on the VNA's serial port and type the help command at the prompt. You will get a list of all the commands available through the VNA's console. I used this to calibrate the touch surface using touchcal. Unfortunately, it doesn't store the touch calibration update. |
Re: Translated instructions
You can access additional commands by connecting the unit to your PC, opening a terminal on the VNA's serial port and type the help command at the prompt.
You will get a list of all the commands available through the VNA's console. I used this to calibrate the touch surface using touchcal. Unfortunately, it doesn't store the touch calibration update. |
Re: NanoVNA software on windows 10 x64?
Yes, it works fine. I have had no issue loading Touchstone snp files from my simulator tool and from the nanoVNA. I am running Windows 10. Note if you have the 2 track unit you will only process s11 functions like Smith, log mag, vswr, etc... if you have 4 track then you can process s11 and s21 data.
If you read in a snp file you will be able to look at all parameters... I believe. I'll check to be sure that is true. Alan |