Date

Re: NanoVNA-Saver 0.0.12

 

Do it the ISO 8000 way = spaces


Which Firmware Version?

W5DXP
 

I am presently running the 300_ch (9-11-19) version of the firmware because I use the NanoVNA primarily for HF. I see that the latest version is edy555_bugfix (10-1-19). Would it be a good idea to install the latest version even though I don't need the UHF function? In general, how does one decide which version to install?


Re: Another modified nanoVNA software

 

I would like to try the software.

Rick LU4FDV


Re: Windows 7 USB Driver problem - not working

 

Hi Nigel,
looks like the driver was the culprit! If nothing is shown in the box where
it probably says "COM17" by now, it means the software hasn't detected the
NanoVNA. I guess that could be clearer ;-)

I hope you have good use out of it!

--
Rune / 5Q5R

On Tue, 1 Oct 2019 at 16:54, Nigel <zs6rn@...> wrote:

Good afternoon from sunny South Africa :-)

Updates:

Rune - Copy of log file(s) created below FYI but not much to analyze...
Also a screen shot of the command window and log file from a USB 'trace' in
case of interest / value) that may assist your development(s) in some
way(?).

Oristo - Thanks for the link to another driver, although was already on
system I have updated with the newer version based on the file name
(en.stsw-stm 32080 vs en.stsw-stm 32102) and after a re-boot and changing
device driver from ChibOS/RT Virtual Com port to the one from st.com, the
nanovna now has a port number - PROGRESS!

Running NanoVNA-Saver now shows the associated port number AND connection
is possible <BIG Smile>.

Now I have additional (fun) stuff to learn which will hopefully keep my
cerebral cells busy...

Gyula - Thank you for taking time to reply, thankfully a change of driver
was the 'simple' fix.

Thank you all again for your interest and support, it really is a
FANTASTIC community to be a party of :-)

Best regards

Nigel R

Content below this line probably only of interest if similar issues
encountered by others and / or for reference.
Sorry for consuming bandwidth / space if inappropriate.

-----------------------------------------------------------------------------------------------------------------------------
LogFile 1
2019-10-01 15:20:03,761 - NanoVNASaver - INFO - Startup...
2019-10-01 15:20:04,412 - NanoVNASaver.SweepWorker - INFO - Initializing
SweepWorker
2019-10-01 15:20:04,512 - NanoVNASaver.NanoVNASaver - DEBUG - Building
user interface
2019-10-01 15:20:05,303 - NanoVNASaver.NanoVNASaver - DEBUG - Finished
building interface
2019-10-01 15:22:35,569 - NanoVNASaver - INFO - Startup...
2019-10-01 15:22:36,100 - NanoVNASaver.SweepWorker - INFO - Initializing
SweepWorker
2019-10-01 15:22:36,190 - NanoVNASaver.NanoVNASaver - DEBUG - Building
user interface
2019-10-01 15:22:36,981 - NanoVNASaver.NanoVNASaver - DEBUG - Finished
building interface

LogFile 2 after change of driver
2019-10-01 15:38:26,009 - NanoVNASaver - INFO - Startup...
2019-10-01 15:38:26,620 - NanoVNASaver.SweepWorker - INFO - Initializing
SweepWorker
2019-10-01 15:38:26,730 - NanoVNASaver.NanoVNASaver - INFO - Found NanoVNA
(0483 5740) on port COM17
2019-10-01 15:38:26,730 - NanoVNASaver.NanoVNASaver - DEBUG - Building
user interface
2019-10-01 15:38:31,918 - NanoVNASaver.NanoVNASaver - DEBUG - Finished
building interface
2019-10-01 15:38:36,845 - NanoVNASaver.NanoVNASaver - INFO - Opening
serial port COM17

Screenshot is console with non working driver.

Error message below reported after initial attempt to use with new driver
but as reported all well second and subsequent times.

\\?\usb#vid_0483&pid_5740#400#{a5dcbf10-6530-11d2-901f-00c04fb951ed}

Description:
A problem caused this program to stop interacting with Windows.
Problem signature:
Problem Event Name: AppHangB1
Application Name: nanovna-saver.v0.0.12.exe
Application Version: 0.0.0.0
Application Timestamp: 5d24a31b
Hang Signature: c143
Hang Type: 0
OS Version: 6.1.7601.2.1.0.256.48
Locale ID: 7177
Additional Hang Signature 1: c143197821453067c6fca61d7dec776f
Additional Hang Signature 2: ef39
Additional Hang Signature 3: ef3942ff81a6672d8bee95d6e5eccc0c
Additional Hang Signature 4: c143
Additional Hang Signature 5: c143197821453067c6fca61d7dec776f
Additional Hang Signature 6: ef39
Additional Hang Signature 7: ef3942ff81a6672d8bee95d6e5eccc0c

USB Tree (non working driver)
======================== USB Device ========================

+++++++++++++++++ Device Information ++++++++++++++++++
Device Description : ChibiOS/RT Virtual COM Port
Device Path :
\\?\usb#vid_0483&pid_5740#400#{a5dcbf10-6530-11d2-901f-00c04fb951ed}
Device ID : USB\VID_0483&PID_5740\400
Hardware IDs : USB\VID_0483&PID_5740&REV_0200
USB\VID_0483&PID_5740
Driver KeyName : {88bae032-5a81-49f0-bc3d-a4ff138216d6}\0000
({88BAE032-5A81-49F0-BC3D-A4FF138216D6})
Driver : system32\DRIVERS\WinUsb.sys (Version:
6.1.7601.17514 Date: 2010-11-20)
Driver Inf : C:\Windows\inf\oem40.inf
Legacy BusType : PNPBus
Class : USBDevice
Class GUID : {88bae032-5a81-49f0-bc3d-a4ff138216d6}
Interface GUID : {a5dcbf10-6530-11d2-901f-00c04fb951ed}
(GUID_DEVINTERFACE_USB_DEVICE)
Service : WinUSB
Enumerator : USB
Location Info : Port_#0002.Hub_#0005
Location IDs :
PCIROOT(0)#PCI(1E00)#PCI(0400)#PCI(0000)#USBROOT(0)#USB(2)
Container ID : {760c3622-4a59-596d-bacb-13523c1ebcfe}
Manufacturer Info : STMicroelectronics
Capabilities : 0x14 (Removable, UniqueID)
Status : 0x0180600A (DN_DRIVER_LOADED, DN_STARTED,
DN_DISABLEABLE, DN_REMOVABLE, DN_NT_ENUMERATOR, DN_NT_DRIVER)
Problem Code : 0
Power State : D0 (supported: D0, D2, D3, wake from D0, wake
from D2)

---------------- Connection Information ---------------
Connection Index : 0x02 (2)
Connection Status : 0x01 (DeviceConnected)
Current Config Value : 0x01
Device Address : 0x01 (1)
Is Hub : 0x00 (no)
Device Bus Speed : 0x01 (Full-Speed)
Number Of Open Pipes : 0x03 (3 pipes to data endpoints)
Pipe[0] : EndpointID=2 Direction=IN ScheduleOffset=0
Type=Interrupt
Pipe[1] : EndpointID=1 Direction=OUT ScheduleOffset=0
Type=Bulk
Pipe[2] : EndpointID=1 Direction=IN ScheduleOffset=0
Type=Bulk
Data (HexDump) : 02 00 00 00 12 01 10 01 02 00 00 40 83 04 40
57 ...........@..@W
00 02 01 02 03 01 01 01 00 01 00 03 00 00 00
01 ................
00 00 00 07 05 82 03 08 00 FF 00 00 00 00 07
05 ................
01 02 40 00 00 00 00 00 00 07 05 81 02 40 00
00 ..@..........@..
00 00 00 00
....

---------------------- Device Descriptor ----------------------
bLength : 0x12 (18 bytes)
bDescriptorType : 0x01 (Device Descriptor)
bcdUSB : 0x110 (USB Version 1.10)
bDeviceClass : 0x02 (Communications and CDC Control)
bDeviceSubClass : 0x00
bDeviceProtocol : 0x00 (No class specific protocol required)
bMaxPacketSize0 : 0x40 (64 bytes)
idVendor : 0x0483 (STMicroelectronics)
idProduct : 0x5740
bcdDevice : 0x0200
iManufacturer : 0x01 (String Descriptor 1)
Language 0x0409 : "STMicroelectronics"
iProduct : 0x02 (String Descriptor 2)
Language 0x0409 : "ChibiOS/RT Virtual COM Port"
iSerialNumber : 0x03 (String Descriptor 3)
Language 0x0409 : "400"
bNumConfigurations : 0x01 (1 Configuration)
Data (HexDump) : 12 01 10 01 02 00 00 40 83 04 40 57 00 02 01
02 .......@..@W....
03 01
..

------------------ Configuration Descriptor -------------------
bLength : 0x09 (9 bytes)
bDescriptorType : 0x02 (Configuration Descriptor)
wTotalLength : 0x0043 (67 bytes)
bNumInterfaces : 0x02 (2 Interfaces)
bConfigurationValue : 0x01 (Configuration 1)
iConfiguration : 0x00 (No String Descriptor)
bmAttributes : 0xC0
D7: Reserved, set 1 : 0x01
D6: Self Powered : 0x01 (yes)
D5: Remote Wakeup : 0x00 (no)
D4..0: Reserved, set 0 : 0x00
MaxPower : 0x32 (100 mA)
Data (HexDump) : 09 02 43 00 02 01 00 C0 32 09 04 00 00 01 02
02 ..C.....2.......
01 00 05 24 00 10 01 05 24 01 00 01 04 24 02
02 ...$....$....$..
05 24 06 00 01 07 05 82 03 08 00 FF 09 04 01
00 .$..............
02 0A 00 00 00 07 05 01 02 40 00 00 07 05 81
02 .........@......
40 00 00
@..

---------------- Interface Descriptor -----------------
bLength : 0x09 (9 bytes)
bDescriptorType : 0x04 (Interface Descriptor)
bInterfaceNumber : 0x00
bAlternateSetting : 0x00
bNumEndpoints : 0x01 (1 Endpoint)
bInterfaceClass : 0x02 (Communications and CDC Control)
bInterfaceSubClass : 0x02 (Abstract Control Model)
bInterfaceProtocol : 0x01 (AT Commands defined by ITU-T V.250 etc)
iInterface : 0x00 (No String Descriptor)
Data (HexDump) : 09 04 00 00 01 02 02 01 00
.........

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x05 (5 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x00 (Header Functional Descriptor)
bcdCDC : 0x110 (CDC Version 1.10)
Data (HexDump) : 05 24 00 10 01
.$...

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x05 (5 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x01 (Call Management Functional Descriptor)
bmCapabilities : 0x00
D7..2: : 0x00 (Reserved)
D1 : : 0x00 (sends/receives call management
information only over the Communication Class interface)
D0 : : 0x00 (does not handle call management itself)
bDataInterface : 0x01
Data (HexDump) : 05 24 01 00 01
.$...

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x04 (4 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x02 (Abstract Control Management Functional
Descriptor)
bmCapabilities : 0x02
D7..4: : 0x00 (Reserved)
D3 : : 0x00 (not supports the notification
Network_Connection)
D2 : : 0x00 (not supports the request Send_Break)
D1 : : 0x01 (supports the request combination of
Set_Line_Coding, Set_Control_Line_State, Get_Line_Coding, and the
notification Serial_State)
D0 : : 0x00 (not supports the request combination of
Set_Comm_Feature, Clear_Comm_Feature, and Get_Comm_Feature)
Data (HexDump) : 04 24 02 02
.$..

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x05 (5 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x06 (Union Functional Descriptor)
bControlInterface : 0x00
bSubordinateInterface[0] : 0x01
Data (HexDump) : 05 24 06 00 01
.$...

----------------- Endpoint Descriptor -----------------
bLength : 0x07 (7 bytes)
bDescriptorType : 0x05 (Endpoint Descriptor)
bEndpointAddress : 0x82 (Direction=IN EndpointID=2)
bmAttributes : 0x03 (TransferType=Interrupt)
wMaxPacketSize : 0x0008 (8 bytes)
bInterval : 0xFF (255 ms)
Data (HexDump) : 07 05 82 03 08 00 FF
.......

---------------- Interface Descriptor -----------------
bLength : 0x09 (9 bytes)
bDescriptorType : 0x04 (Interface Descriptor)
bInterfaceNumber : 0x01
bAlternateSetting : 0x00
bNumEndpoints : 0x02 (2 Endpoints)
bInterfaceClass : 0x0A (CDC-Data)
bInterfaceSubClass : 0x00
bInterfaceProtocol : 0x00
iInterface : 0x00 (No String Descriptor)
Data (HexDump) : 09 04 01 00 02 0A 00 00 00
.........

----------------- Endpoint Descriptor -----------------
bLength : 0x07 (7 bytes)
bDescriptorType : 0x05 (Endpoint Descriptor)
bEndpointAddress : 0x01 (Direction=OUT EndpointID=1)
bmAttributes : 0x02 (TransferType=Bulk)
wMaxPacketSize : 0x0040 (64 bytes)
bInterval : 0x00 (ignored)
Data (HexDump) : 07 05 01 02 40 00 00
....@..

----------------- Endpoint Descriptor -----------------
bLength : 0x07 (7 bytes)
bDescriptorType : 0x05 (Endpoint Descriptor)
bEndpointAddress : 0x81 (Direction=IN EndpointID=1)
bmAttributes : 0x02 (TransferType=Bulk)
wMaxPacketSize : 0x0040 (64 bytes)
bInterval : 0x00 (ignored)
Data (HexDump) : 07 05 81 02 40 00 00
....@..

-------------------- String Descriptors -------------------
------ String Descriptor 0 ------
bLength : 0x04 (4 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language ID[0] : 0x0409 (English - United States)
Data (HexDump) : 04 03 09 04
....
------ String Descriptor 1 ------
bLength : 0x26 (38 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language 0x0409 : "STMicroelectronics"
Data (HexDump) : 26 03 53 00 54 00 4D 00 69 00 63 00 72 00 6F
00 &.S.T.M.i.c.r.o.
65 00 6C 00 65 00 63 00 74 00 72 00 6F 00 6E
00 e.l.e.c.t.r.o.n.
69 00 63 00 73 00
i.c.s.
------ String Descriptor 2 ------
bLength : 0x38 (56 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language 0x0409 : "ChibiOS/RT Virtual COM Port"
Data (HexDump) : 38 03 43 00 68 00 69 00 62 00 69 00 4F 00 53
00 8.C.h.i.b.i.O.S.
2F 00 52 00 54 00 20 00 56 00 69 00 72 00 74
00 /.R.T. .V.i.r.t.
75 00 61 00 6C 00 20 00 43 00 4F 00 4D 00 20
00 u.a.l. .C.O.M. .
50 00 6F 00 72 00 74 00
P.o.r.t.
------ String Descriptor 3 ------
bLength : 0x08 (8 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language 0x0409 : "400"
Data (HexDump) : 08 03 34 00 30 00 30 00
..4.0.0.















Re: Windows 7 USB Driver problem - not working

 

Hi Nigel -

I have updated with the newer version based on the file name (en.stsw-stm 32080 vs en.stsw-stm 32102)
and after a re-boot and changing device driver from ChibOS/RT Virtual Com port
to the one from st.com, the nanovna now has a port number
It's good when a plan works. I have little Windows 7 experience.
(I found Vista so awful that I pretty much stuck with XP SP2 until 8.1)

Firmware updates almost certainly require STM's driver, if you ever attempt.


Re: What's your use of the NanoVNA - mainly outside or mainly laboratory? What features do you want?

 

From: Dr. David Kirkby from Kirkby Microwave Ltd

Rune's NanoVNA-Saver looks a lovely bit of software, but it is not much
good unless you work outside, unless willing to take a PC worth you.
===================================

I've used a Windows tablet PC for demonstration purposes, and something like this /might/ suit you:



I run nanoVNA-saver on a 10-inch earlier model (the one where 1/3 of the 64 GB of storage is eaten by an unused Android partition).

73,
David GM8ARV
--
SatSignal Software - Quality software for you
Web:
Email: david-taylor@...
Twitter: @gm8arv


Re: What's your use of the NanoVNA - mainly outside or mainly laboratory? What features do you want?

W5DXP
 

Up until now, I have used my $450 AIM-4170D for measurements made inside the shack and it is capable of being calibrated to make remote measurements from the shack. Calibrating for those remote measurements is a pain plus the AIM-4170D requires a 12v supply and a PC or laptop for it to function. My decisions have been (1) run back and forth between remote measurement point and shack in order to do the calibration or (2) Lug a 12v battery and laptop to the remote measurement point (sometimes on the roof or up a tree). Up until now, I have relied on my $120 Autek VA1 for those vest pocket difficult remote measurements but the Alpha-Numeric+ display is clumsy. Except for a couple of nagging problems, e.g. bright sunshine, the NanoVNA solves those problems. One idea I have had is to marry the NanoVNA to a portable RPi system (larger display) running NanoVNA-Saver. Some hams are already running WSJT-X and FLDigi on such portable battery-powered systems.


Re: Installed recent firmware - was this a big mistake?

 

Hi Bryan,
sweeping currently works as follows:
1) The requested frequency range is set (start and stop frequency)
2) A delay of 300 ms
3) The frequencies are read back by sending the text "frequencies", waiting
50 ms, and then reading them
4) The S11 data is read (again, 50 ms delay included)
5) The S21 data is read

I decided on 300 ms after testing a few times, and figuring that it was
"probably fine". Setting no delay sometimes let to errors, and more than
250 ms seemed to be fine, so I set it to 300. Maybe it's too low? But
then I was using Hugen's firmware.

If you can make a non-continuous sweep that produces a noticeable error,
you can try exporting the S1P/S2P Touchstone file, and looking at the
frequencies. The Touchstone export reads the exact frequencies reported
back by the NanoVNA, so it should tell you what frequencies it thinks it's
reporting data for.

Sadly I don't think it's something I can really address in the application
- I believe it has to be accounted for in the firmware.

Thanks for the work you're doing on this issue, though! Good luck with it!

--
Rune / 5Q5R

On Tue, 1 Oct 2019 at 16:40, bryburns via Groups.Io <bryburns=
[email protected]> wrote:

Rune,

Thanks for taking a look at this thread!

My biggest concern is that with the firmware 0.2.2 from edy555 I always
see incorrect data in the second scan when using 2 scans between 80 and 120
MHz. With a single scan there are no errors over the same frequency
range. The incorrect data is always wrong in the same way. I.E. it is
actual measurements but they are from the wrong frequencies. If I do 5
scans, it appears that the first part of scans 2 through 5 is almost always
incorrect data. If it were occasional errors, I could work with it;
however, it is repeated with my nanoVNA and this firmware. When I request
a single scan over the exact same frequencies as the 2nd or 3rd or 4th or
5th scan, I very rarely, if ever, see an error in the nanoVNA-Saver data,
even in continuous sweep mode. What is different about continuous sweep
mode? Is there a pause between the scans?

I very rarely, if ever, see it with firmware from hugen dated August 2,
2019 using the exact same scan settings 2 or 3 or 4 or 5... Yes, I will
occasionally see errors with the hugen firmware but they are quite rare and
usually pretty obvious. Repeating a sweep or measurement will clear the
errant data.

I don't know much about the transfer protocol between the nanoVNA and the
PC. From your comment above, I would have to assume that you do not get
the frequency information in the same message as the data so there is no
way to throw out data based on the fact that the frequencies you requested
are not the frequencies sent from the nanoVNA. Is that correct?

A few questions, mostly thinking out loud. :>) I wonder if data is being
sent from the firmware before the hardware has actually stabilized at the
new frequencies you have requested? Would it help to pause a bit after
requesting a new set of frequencies?

I will continue looking for more clues to this issue.

--
Bryan, WA5VAH




Re: Windows 7 USB Driver problem - not working

 

Good afternoon from sunny South Africa :-)

Updates:

Rune - Copy of log file(s) created below FYI but not much to analyze... Also a screen shot of the command window and log file from a USB 'trace' in case of interest / value) that may assist your development(s) in some way(?).

Oristo - Thanks for the link to another driver, although was already on system I have updated with the newer version based on the file name (en.stsw-stm 32080 vs en.stsw-stm 32102) and after a re-boot and changing device driver from ChibOS/RT Virtual Com port to the one from st.com, the nanovna now has a port number - PROGRESS!

Running NanoVNA-Saver now shows the associated port number AND connection is possible <BIG Smile>.

Now I have additional (fun) stuff to learn which will hopefully keep my cerebral cells busy...

Gyula - Thank you for taking time to reply, thankfully a change of driver was the 'simple' fix.

Thank you all again for your interest and support, it really is a FANTASTIC community to be a party of :-)

Best regards

Nigel R

Content below this line probably only of interest if similar issues encountered by others and / or for reference.
Sorry for consuming bandwidth / space if inappropriate.
-----------------------------------------------------------------------------------------------------------------------------
LogFile 1
2019-10-01 15:20:03,761 - NanoVNASaver - INFO - Startup...
2019-10-01 15:20:04,412 - NanoVNASaver.SweepWorker - INFO - Initializing SweepWorker
2019-10-01 15:20:04,512 - NanoVNASaver.NanoVNASaver - DEBUG - Building user interface
2019-10-01 15:20:05,303 - NanoVNASaver.NanoVNASaver - DEBUG - Finished building interface
2019-10-01 15:22:35,569 - NanoVNASaver - INFO - Startup...
2019-10-01 15:22:36,100 - NanoVNASaver.SweepWorker - INFO - Initializing SweepWorker
2019-10-01 15:22:36,190 - NanoVNASaver.NanoVNASaver - DEBUG - Building user interface
2019-10-01 15:22:36,981 - NanoVNASaver.NanoVNASaver - DEBUG - Finished building interface

LogFile 2 after change of driver
2019-10-01 15:38:26,009 - NanoVNASaver - INFO - Startup...
2019-10-01 15:38:26,620 - NanoVNASaver.SweepWorker - INFO - Initializing SweepWorker
2019-10-01 15:38:26,730 - NanoVNASaver.NanoVNASaver - INFO - Found NanoVNA (0483 5740) on port COM17
2019-10-01 15:38:26,730 - NanoVNASaver.NanoVNASaver - DEBUG - Building user interface
2019-10-01 15:38:31,918 - NanoVNASaver.NanoVNASaver - DEBUG - Finished building interface
2019-10-01 15:38:36,845 - NanoVNASaver.NanoVNASaver - INFO - Opening serial port COM17

Screenshot is console with non working driver.

Error message below reported after initial attempt to use with new driver but as reported all well second and subsequent times.

\\?\usb#vid_0483&pid_5740#400#{a5dcbf10-6530-11d2-901f-00c04fb951ed}

Description:
A problem caused this program to stop interacting with Windows.
Problem signature:
Problem Event Name: AppHangB1
Application Name: nanovna-saver.v0.0.12.exe
Application Version: 0.0.0.0
Application Timestamp: 5d24a31b
Hang Signature: c143
Hang Type: 0
OS Version: 6.1.7601.2.1.0.256.48
Locale ID: 7177
Additional Hang Signature 1: c143197821453067c6fca61d7dec776f
Additional Hang Signature 2: ef39
Additional Hang Signature 3: ef3942ff81a6672d8bee95d6e5eccc0c
Additional Hang Signature 4: c143
Additional Hang Signature 5: c143197821453067c6fca61d7dec776f
Additional Hang Signature 6: ef39
Additional Hang Signature 7: ef3942ff81a6672d8bee95d6e5eccc0c

USB Tree (non working driver)
======================== USB Device ========================

+++++++++++++++++ Device Information ++++++++++++++++++
Device Description : ChibiOS/RT Virtual COM Port
Device Path : \\?\usb#vid_0483&pid_5740#400#{a5dcbf10-6530-11d2-901f-00c04fb951ed}
Device ID : USB\VID_0483&PID_5740\400
Hardware IDs : USB\VID_0483&PID_5740&REV_0200 USB\VID_0483&PID_5740
Driver KeyName : {88bae032-5a81-49f0-bc3d-a4ff138216d6}\0000 ({88BAE032-5A81-49F0-BC3D-A4FF138216D6})
Driver : system32\DRIVERS\WinUsb.sys (Version: 6.1.7601.17514 Date: 2010-11-20)
Driver Inf : C:\Windows\inf\oem40.inf
Legacy BusType : PNPBus
Class : USBDevice
Class GUID : {88bae032-5a81-49f0-bc3d-a4ff138216d6}
Interface GUID : {a5dcbf10-6530-11d2-901f-00c04fb951ed} (GUID_DEVINTERFACE_USB_DEVICE)
Service : WinUSB
Enumerator : USB
Location Info : Port_#0002.Hub_#0005
Location IDs : PCIROOT(0)#PCI(1E00)#PCI(0400)#PCI(0000)#USBROOT(0)#USB(2)
Container ID : {760c3622-4a59-596d-bacb-13523c1ebcfe}
Manufacturer Info : STMicroelectronics
Capabilities : 0x14 (Removable, UniqueID)
Status : 0x0180600A (DN_DRIVER_LOADED, DN_STARTED, DN_DISABLEABLE, DN_REMOVABLE, DN_NT_ENUMERATOR, DN_NT_DRIVER)
Problem Code : 0
Power State : D0 (supported: D0, D2, D3, wake from D0, wake from D2)

---------------- Connection Information ---------------
Connection Index : 0x02 (2)
Connection Status : 0x01 (DeviceConnected)
Current Config Value : 0x01
Device Address : 0x01 (1)
Is Hub : 0x00 (no)
Device Bus Speed : 0x01 (Full-Speed)
Number Of Open Pipes : 0x03 (3 pipes to data endpoints)
Pipe[0] : EndpointID=2 Direction=IN ScheduleOffset=0 Type=Interrupt
Pipe[1] : EndpointID=1 Direction=OUT ScheduleOffset=0 Type=Bulk
Pipe[2] : EndpointID=1 Direction=IN ScheduleOffset=0 Type=Bulk
Data (HexDump) : 02 00 00 00 12 01 10 01 02 00 00 40 83 04 40 57 ...........@..@W
00 02 01 02 03 01 01 01 00 01 00 03 00 00 00 01 ................
00 00 00 07 05 82 03 08 00 FF 00 00 00 00 07 05 ................
01 02 40 00 00 00 00 00 00 07 05 81 02 40 00 00 ..@..........@..
00 00 00 00 ....

---------------------- Device Descriptor ----------------------
bLength : 0x12 (18 bytes)
bDescriptorType : 0x01 (Device Descriptor)
bcdUSB : 0x110 (USB Version 1.10)
bDeviceClass : 0x02 (Communications and CDC Control)
bDeviceSubClass : 0x00
bDeviceProtocol : 0x00 (No class specific protocol required)
bMaxPacketSize0 : 0x40 (64 bytes)
idVendor : 0x0483 (STMicroelectronics)
idProduct : 0x5740
bcdDevice : 0x0200
iManufacturer : 0x01 (String Descriptor 1)
Language 0x0409 : "STMicroelectronics"
iProduct : 0x02 (String Descriptor 2)
Language 0x0409 : "ChibiOS/RT Virtual COM Port"
iSerialNumber : 0x03 (String Descriptor 3)
Language 0x0409 : "400"
bNumConfigurations : 0x01 (1 Configuration)
Data (HexDump) : 12 01 10 01 02 00 00 40 83 04 40 57 00 02 01 02 .......@..@W....
03 01 ..

------------------ Configuration Descriptor -------------------
bLength : 0x09 (9 bytes)
bDescriptorType : 0x02 (Configuration Descriptor)
wTotalLength : 0x0043 (67 bytes)
bNumInterfaces : 0x02 (2 Interfaces)
bConfigurationValue : 0x01 (Configuration 1)
iConfiguration : 0x00 (No String Descriptor)
bmAttributes : 0xC0
D7: Reserved, set 1 : 0x01
D6: Self Powered : 0x01 (yes)
D5: Remote Wakeup : 0x00 (no)
D4..0: Reserved, set 0 : 0x00
MaxPower : 0x32 (100 mA)
Data (HexDump) : 09 02 43 00 02 01 00 C0 32 09 04 00 00 01 02 02 ..C.....2.......
01 00 05 24 00 10 01 05 24 01 00 01 04 24 02 02 ...$....$....$..
05 24 06 00 01 07 05 82 03 08 00 FF 09 04 01 00 .$..............
02 0A 00 00 00 07 05 01 02 40 00 00 07 05 81 02 .........@......
40 00 00 @..

---------------- Interface Descriptor -----------------
bLength : 0x09 (9 bytes)
bDescriptorType : 0x04 (Interface Descriptor)
bInterfaceNumber : 0x00
bAlternateSetting : 0x00
bNumEndpoints : 0x01 (1 Endpoint)
bInterfaceClass : 0x02 (Communications and CDC Control)
bInterfaceSubClass : 0x02 (Abstract Control Model)
bInterfaceProtocol : 0x01 (AT Commands defined by ITU-T V.250 etc)
iInterface : 0x00 (No String Descriptor)
Data (HexDump) : 09 04 00 00 01 02 02 01 00 .........

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x05 (5 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x00 (Header Functional Descriptor)
bcdCDC : 0x110 (CDC Version 1.10)
Data (HexDump) : 05 24 00 10 01 .$...

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x05 (5 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x01 (Call Management Functional Descriptor)
bmCapabilities : 0x00
D7..2: : 0x00 (Reserved)
D1 : : 0x00 (sends/receives call management information only over the Communication Class interface)
D0 : : 0x00 (does not handle call management itself)
bDataInterface : 0x01
Data (HexDump) : 05 24 01 00 01 .$...

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x04 (4 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x02 (Abstract Control Management Functional Descriptor)
bmCapabilities : 0x02
D7..4: : 0x00 (Reserved)
D3 : : 0x00 (not supports the notification Network_Connection)
D2 : : 0x00 (not supports the request Send_Break)
D1 : : 0x01 (supports the request combination of Set_Line_Coding, Set_Control_Line_State, Get_Line_Coding, and the notification Serial_State)
D0 : : 0x00 (not supports the request combination of Set_Comm_Feature, Clear_Comm_Feature, and Get_Comm_Feature)
Data (HexDump) : 04 24 02 02 .$..

-------------- CDC Interface Descriptor ---------------
bFunctionLength : 0x05 (5 bytes)
bDescriptorType : 0x24 (Interface)
bDescriptorSubType : 0x06 (Union Functional Descriptor)
bControlInterface : 0x00
bSubordinateInterface[0] : 0x01
Data (HexDump) : 05 24 06 00 01 .$...

----------------- Endpoint Descriptor -----------------
bLength : 0x07 (7 bytes)
bDescriptorType : 0x05 (Endpoint Descriptor)
bEndpointAddress : 0x82 (Direction=IN EndpointID=2)
bmAttributes : 0x03 (TransferType=Interrupt)
wMaxPacketSize : 0x0008 (8 bytes)
bInterval : 0xFF (255 ms)
Data (HexDump) : 07 05 82 03 08 00 FF .......

---------------- Interface Descriptor -----------------
bLength : 0x09 (9 bytes)
bDescriptorType : 0x04 (Interface Descriptor)
bInterfaceNumber : 0x01
bAlternateSetting : 0x00
bNumEndpoints : 0x02 (2 Endpoints)
bInterfaceClass : 0x0A (CDC-Data)
bInterfaceSubClass : 0x00
bInterfaceProtocol : 0x00
iInterface : 0x00 (No String Descriptor)
Data (HexDump) : 09 04 01 00 02 0A 00 00 00 .........

----------------- Endpoint Descriptor -----------------
bLength : 0x07 (7 bytes)
bDescriptorType : 0x05 (Endpoint Descriptor)
bEndpointAddress : 0x01 (Direction=OUT EndpointID=1)
bmAttributes : 0x02 (TransferType=Bulk)
wMaxPacketSize : 0x0040 (64 bytes)
bInterval : 0x00 (ignored)
Data (HexDump) : 07 05 01 02 40 00 00 ....@..

----------------- Endpoint Descriptor -----------------
bLength : 0x07 (7 bytes)
bDescriptorType : 0x05 (Endpoint Descriptor)
bEndpointAddress : 0x81 (Direction=IN EndpointID=1)
bmAttributes : 0x02 (TransferType=Bulk)
wMaxPacketSize : 0x0040 (64 bytes)
bInterval : 0x00 (ignored)
Data (HexDump) : 07 05 81 02 40 00 00 ....@..

-------------------- String Descriptors -------------------
------ String Descriptor 0 ------
bLength : 0x04 (4 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language ID[0] : 0x0409 (English - United States)
Data (HexDump) : 04 03 09 04 ....
------ String Descriptor 1 ------
bLength : 0x26 (38 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language 0x0409 : "STMicroelectronics"
Data (HexDump) : 26 03 53 00 54 00 4D 00 69 00 63 00 72 00 6F 00 &.S.T.M.i.c.r.o.
65 00 6C 00 65 00 63 00 74 00 72 00 6F 00 6E 00 e.l.e.c.t.r.o.n.
69 00 63 00 73 00 i.c.s.
------ String Descriptor 2 ------
bLength : 0x38 (56 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language 0x0409 : "ChibiOS/RT Virtual COM Port"
Data (HexDump) : 38 03 43 00 68 00 69 00 62 00 69 00 4F 00 53 00 8.C.h.i.b.i.O.S.
2F 00 52 00 54 00 20 00 56 00 69 00 72 00 74 00 /.R.T. .V.i.r.t.
75 00 61 00 6C 00 20 00 43 00 4F 00 4D 00 20 00 u.a.l. .C.O.M. .
50 00 6F 00 72 00 74 00 P.o.r.t.
------ String Descriptor 3 ------
bLength : 0x08 (8 bytes)
bDescriptorType : 0x03 (String Descriptor)
Language 0x0409 : "400"
Data (HexDump) : 08 03 34 00 30 00 30 00 ..4.0.0.


Re: NanoVNA V2

 

I agree.
How about a soft-switch to enable external communication either through the USB port OR a serial port that could be connected to a Bluetooth Dongle?

My 0.02

...Larry


Re: errors of "error" models

 

25 : The concept of Quantity today

Hello,

Our Objective World adopted * p a r t s * of the following:

VIM - International Vocabulary of Metrology



JCGM_200_2012.pdf - 4,024,384 bytes

Author : BIPM
Title: JCGM 200:2012 - International vocabulary of metrology -
Basic and general concepts and associated terms (VIM)
PDF Version : 1.6
Pages Count : 108

p.viii:

The present Vocabulary pertains to metrology, the ¡°science of
measurement and its application¡±.

p.18 - Left Column

1.1 (1.1)
quantity
property of a phenomenon, body, or substance, where the property
has a magnitude that can be expressed as a number and a
reference

NOTE 2
A reference can be a measurement unit, a measurement procedure,
a reference material, or a combination of such.

After that, we put parentheses "( )" around the undefined terms
and square brackets around the defined terms in the above entries
of this very version of VIM, to get the following:

[quantity]
(property) of a : (phenomenon), (body), or (substance), where
the (property) has a (magnitude) that can be expressed as a
number and a [reference]

A [reference] can be a [measurement unit], a [measurement
procedure], a [reference (material)], or a combination of such.

Sincerely,

gin&pez@arg

25


Re: Installed recent firmware - was this a big mistake?

 

Rune,

Thanks for taking a look at this thread!

My biggest concern is that with the firmware 0.2.2 from edy555 I always see incorrect data in the second scan when using 2 scans between 80 and 120 MHz. With a single scan there are no errors over the same frequency range. The incorrect data is always wrong in the same way. I.E. it is actual measurements but they are from the wrong frequencies. If I do 5 scans, it appears that the first part of scans 2 through 5 is almost always incorrect data. If it were occasional errors, I could work with it; however, it is repeated with my nanoVNA and this firmware. When I request a single scan over the exact same frequencies as the 2nd or 3rd or 4th or 5th scan, I very rarely, if ever, see an error in the nanoVNA-Saver data, even in continuous sweep mode. What is different about continuous sweep mode? Is there a pause between the scans?

I very rarely, if ever, see it with firmware from hugen dated August 2, 2019 using the exact same scan settings 2 or 3 or 4 or 5... Yes, I will occasionally see errors with the hugen firmware but they are quite rare and usually pretty obvious. Repeating a sweep or measurement will clear the errant data.

I don't know much about the transfer protocol between the nanoVNA and the PC. From your comment above, I would have to assume that you do not get the frequency information in the same message as the data so there is no way to throw out data based on the fact that the frequencies you requested are not the frequencies sent from the nanoVNA. Is that correct?

A few questions, mostly thinking out loud. :>) I wonder if data is being sent from the firmware before the hardware has actually stabilized at the new frequencies you have requested? Would it help to pause a bit after requesting a new set of frequencies?

I will continue looking for more clues to this issue.

--
Bryan, WA5VAH


What's your use of the NanoVNA - mainly outside or mainly laboratory? What features do you want?

Dr. David Kirkby from Kirkby Microwave Ltd
 

It is clear from some of the comments I have seen here, that different
people have different uses for the NanoVNA. I'm just trying to get some
idea of what percentage of people have such uses, as it dictates whether
internal firmware or external programs like Nano-Sharp are of primary
importance to them. It is also likely to affect the screen size they want.

1) Some, like myself, want to use the NanoVNA away from a laboratory or
radio shack - most likely outside working on feeders, antennas or similar,
but maybe with antennas in loft spaces or similar.

Such people are likely to want at least some of the following.
* Bigger better screens readable in bright light.
* Support in the *firmware* for decent calibration standards
* Support in the *firmware* for other features like time domain
reflectometry (TDR)
* Such people are less likely to be interested in the capabilities of
external software such as VNA-Savert.
* Rugged device, suitable for outside use.

Rune's NanoVNA-Saver looks a lovely bit of software, but it is not much
good unless you work outside, unless willing to take a PC worth you.

*Please understand, I'm not getting at Rune here. In fact, I've been
thinking about the possibilites of using his sofware with HP VNAs. I'm sure
virtually any data that can be taken from the NanoVNA, could probably be
taken from the HP VNAs. Anything that could not be obtained from the HP
VNAs, could probably be ignored. Of course, all the command would be
different, but I don't see that as a major problem. Most of the work is in
the GUI I believe. *

2) Others are likely to use the instrument mainly inside a shack or
laboratory. For them
* The capabilities of external software, like NanoVNA-Saver, will be *very*
important.
* Facilities like TDR, or good calibration facilities in the firmware are
lunikely to be important, as external software can do this on a large
screen.
* NanoVNA screen size is possibly less importance, as being able to read
the screen outside clearly is no that imporant.

3) Some might be a mix of the two. In what case, what percentage of time do
you consider using the NanoVNA in such of the environments?

--
Dr David Kirkby Ph.D C.Eng MIET
Kirkby Microwave Ltd
Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, CHELMSFORD,
Essex, CM3 6DT, United Kingdom.
Registered in England and Wales as company number 08914892

Tel 01621-680100 / +44 1621-680100


Re: NanoVNA-F

 

Hi John AE5X -

Are the main (only?) differences in the -F that it has a 100 MHz higher upper
frequency limit and a bigger display?
No, it has an incompatible processor that may support more/different functionality.
Please check out and/or /g/nanovna-f


Re: Is there an Android app for the NanoVNA - WebUSB

 

Hi Larry -

the following two links ONLY work with Chrome browser
Oops, I forget that hover tooltips fail for touchscreens,
but the second URL should work..

how do you access the client on your tablet?


Re: NanoVNA-Saver 0.0.12

 

Hi Dwight,
thanks for trying out the software!

The calibration save/load functions are probably changing in the next
release, and will have OS-provided file picker dialogues, so it should be a
*lot* easier to find the file you want.

Formatting for frequencies is a good idea. I'm still internally debating
how to do it properly: Thousands separators, scientific notation (9e8 for
your example?) or trying something that works with G/M/k (900M is easy, but
123,456,789 represented as 123.456789MHz is ... less nice.)

Thank you for the suggestions, keep them coming! :-)

--
Rune / 5Q5R

On Tue, 1 Oct 2019 at 16:02, Dwight Merkley <demerkley@...> wrote:

Hi Rune,

First let me thank you for sharing your excellent nanoVNA-Saver
application!
Your time and efforts are appreciated.

A couple of suggestion for possible future improvement...

Would it be possible to add some number formatting to make it easier to
read the various frequencies and other values?
ie. instead of 900000000, this is much easier to read 900,000,000
for me it really doesn't matter if you use a comma or a space or a
dot (9 000 000 vs 9.000.000 or 9,000,000 etc, etc)
I find it difficult to quickly and accurately evaluate the numbers
without some sort of delimiter to help visually.


In the calibration section there does not seem to be a way to specify a
folder location for the calibration files.
It is a bit tedious to remember what names the user might have used to
save each calibration so it would be helpful if one could list the
available calibration files that have been saved.

These are just a couple of suggestions.
Mostly I want to thank you for sharing your work!

73
Dwight
N7KBC








Re: Is there an Android app for the NanoVNA - WebUSB

 

oristo -
Thanks for the Wiki post but please change the description to:
" Simple, but the following two links ONLY work with Chrome browser "

Personally, I got it to work on my LG G3 8" tablet that has TWO USB ports - one Client and one dedicated Host.
I'll have to try it on my Chinese Android phone.

Regards,
Larry


Re: NanoVNA-Saver 0.0.12

 

Hi Rune,

First let me thank you for sharing your excellent nanoVNA-Saver application!
Your time and efforts are appreciated.

A couple of suggestion for possible future improvement...

Would it be possible to add some number formatting to make it easier to read the various frequencies and other values?
ie. instead of 900000000, this is much easier to read 900,000,000
for me it really doesn't matter if you use a comma or a space or a dot (9 000 000 vs 9.000.000 or 9,000,000 etc, etc)
I find it difficult to quickly and accurately evaluate the numbers without some sort of delimiter to help visually.


In the calibration section there does not seem to be a way to specify a folder location for the calibration files.
It is a bit tedious to remember what names the user might have used to save each calibration so it would be helpful if one could list the available calibration files that have been saved.

These are just a couple of suggestions.
Mostly I want to thank you for sharing your work!

73
Dwight
N7KBC


Re: Deal on ebay

 

On Mon, Sep 30, 2019 at 03:49 PM, Alan Lloyd wrote:


Hmm. So why buy one if you don't know what it is or what it does?
A
That's exactly the reason to get one. At $50-ish, the NanoVNA is far more than a piece of test gear - it's a learning tool. He'll learn more by having and using it than he will by reading and YouTubing about VNAs.


Re: errors of "error" models

 

- (c) gin&pez@arg (cc-by-4.0) 2019 : start -

24 : The Main Frame of a Possible Communication

There are three 3 Worlds.

The Physical World: Phenomena involving objects
which are created, existed, and destroyed.

The Subjective World: In order to explain and predict
the phenomena : Personal Ideas in correspondence
with those of the Physical World : objects with properties,
in relations, created, existed and destroyed.

The Objective World: The Common Sharable Subjective
World among more than one people.

Sincerely,

gin&pez@arg

- end : (c) gin&pez@arg (cc-by-4.0) 2019 -

23