Have a look here Cheers Al On Wed, 25 Sep 2019 at 12:17, Bruce KX4AZ <bruce@...> wrote:
Rune, |
R + jX ?
I will apologize if this has already been covered. I didn't find it in a search.
I see that, by default, NanoVNA reports R + L/C . Is there a way to change that to R +- X ? Yes, I know the PC software can display it both ways, but my primary use for the NanoVNA is up on the tower, to make measurements at the feedpoint. The NanoVNA is a lot more convenient than carrying up a bulky and expensive antenna analyzer. Thanks, Steve, N2IC |
Re: Firmware font size - 2 versus 4 trace
I have seen a technique where the font is "enlarged" simply by outputting each scan of the character font twice. This makes the character appear taller. It can make the text surprisingly more legible with no more font RAM and just a small hit on the code space. Of course you still will need screen space. Because the characters, while more legible, are a bit ill formed, this might be available as an selectable "ZOOM" mode unneeded by those who purchase the reading glass option.
|
Trying to understand the T-Check outcome of the nanoVNA
Using a not too good BNC Tee I performed a T-Check
Attached the measurement (.s2p) and the excel file (.xlsx) in which the T-Check is calculated. Next to the T-Check calculation the excel also calculates the abs(Zin-Zout)/Z0 (the percentage absolute distance of the two impedances as another estimate of error) The frequency is denoted in MHz Do ignore anything above say 500MHz The T-Check suggests the error quickly increases to substantial levels but the abs(Zin-Zout)/Z0 suggests there is a very systematic error in my measurement where the absolute distance of the two rotating impedances grows very linear with frequency. I did calibrate using the Tee without (OSL) and with (T) the outgoing cable connected but maybe that did result into the error. What am I doing wrong? |
Re: Firmware font size - 2 versus 4 trace
On Wed, Sep 25, 2019 at 09:26 AM, <erik@...> wrote:
Erik, Thanks for confirming memory capacity is a factor in the font sizes. My progressive bifocals work fine with the smaller fonts, but I imagine it's just a matter of time before someone releases a new firmware "flavor" with two traces & 1500 MHz extended range. With the newest firmware versions, can you give us any sense of how close we are the memory capacity "ceiling"? Thanks, Bruce |
Re: Saver with Win7
Thanks Alan! See, I didn't even figure out it was an S21 measurement :D
toggle quoted message
Show quoted text
-- Rune / 5Q5R On Wed, 25 Sep 2019 at 16:37, alan victor <avictor73@...> wrote:
Hi Rune, |
Re: Saver with Win7
Hi Rune,
The group delay (GD) is obtained from the transmission phase, S21. The negated value of phase shift calculated as the small change in phase shift occurring with a small change in frequency. The difference in phase with difference in frequency (the aperture) taken small enough to arrive at an accurate value for GD. The site below is a good reference and provides a useful calculator so you can test your routine: Regards, Alan |
Re: Saver with Win7
Thanks for the suggestion, Bryan. It sounds interesting. Do you know if/how
group delay is determined from S-parameters? I'm not really an RF engineer, so I have had to figure out all these things from the ground up ;-) (Also, no more busy than I can easily answer emails. :-) -- Rune / 5Q5R On Wed, 25 Sep 2019 at 16:17, bryburns via Groups.Io <bryburns= [email protected]> wrote: peter_pc2a |
Re: Saver with Win7
peter_pc2a
I am running nanovna-saver.v0.0.11 on Win 7 - 64 bit and it is working great. The software is very useful and seems to be quite stable. Rune: I know you are quite busy. Here is a suggestion: I would like to see group delay added to the measurements. Thanks, again, for all of your great work. -- Bryan, WA5VAH |
Re: Saver with Win7
Using Thunderbird, and perhaps other email clients, you should see the poster's full email address on the "From" line at the top of the email header. For instance, when I look at your email (to which I am replying here), I see k4tql@....
toggle quoted message
Show quoted text
One can right-click on the email address and copy it. DaveD On 9/25/2019 9:50 AM, BruceN wrote:
A bit off topic, perhaps, but tell me, how do I expand an email address like mihtjel@... ? |
Re: Saver with Win7
Hi Bruce,
toggle quoted message
Show quoted text
I'm not certain quite how it works via groups.io, but I did attempt to put my email (mihtjel@...) in the body of the email I sent earlier, in order that Peter (and others) could contact me directly, should they need to. I should probably set up an official email address for nanovna-saver at some point, given the number of users it's starting to accrue, but for now, gmail is doing fine at sorting them for me. ;-) -- Rune On Wed, 25 Sep 2019 at 15:50, BruceN <k4tql@...> wrote:
A bit off topic, perhaps, but tell me, how do I expand an email address |
Re: Firmware font size - 2 versus 4 trace
Indeed, larger fonts need more memory. Prefer to spend memory on more useful features. Suggest to buy small reading glasses. I did.....
Hugen does not have the large font size version on github (I can not find it) and I'm using the edy555 version as a starting point |
Re: Firmware font size - 2 versus 4 trace
Erik,
toggle quoted message
Show quoted text
Is there enough firmware space on the uP for one more firmware on-screen option to display either 2 larger or 4 smaller traces? I think that would be a nice option to have. I know Hugen's firmware for the 2 trace version was quite a bit larger in size though. Thanks, Larry On Wed, Sep 25, 2019 at 08:24 AM, Bruce KX4AZ wrote:
|
Firmware font size - 2 versus 4 trace
I like the new 1500 MHz firmware - but I do miss the larger font size of the original 2 trace "antenna analyzer" version my nanoVNA shipped with. Wondering if there is some inherent reason why the larger font can't be used with 4 trace firmware, other than the screen getting too crowded with text.
|
Re: errors of "error" models
@yza
As I am not scientifically trained I have great difficulty to follow your posts and to understand what it is you ask. - Are you merely sharing knowledge on error models applicable to VNA? Great, need some help on how we can use your knowledge to understand the limitations of our own measurements - Do you invite only those with a solid scientific background to participate in an performance evaluation of the nanoVNA? Excellent, let the experts join and deliver a solid foundation to understand the limitations of nanoVNA performance - Do you want the wider group to participate? If so, in what way? How to contribute? Please help me to understand. |
Re: NanoVNA Saver
Rune,
Wanted to add my thanks for all the work you have done with the software, and I really appreciate the features added to the latest version. I've never been able to do a calibration within the software, no doubt I am doing something wrong with the key sequence. Calibration works fine with the touch screen, so not really an issue...but I do wonder if someone has ever written a calibration "tutorial" about how it is done in the NanoVNA Saver software. 73, Bruce |
Re: on the comparisons
Hi David
I have noted your comment. As far as I know many are using Linux as platform. Look in the Yahoo Forum for details and probably also in the help file which exist as pdf. Regarding licensing I know people are invited to used the VNWA and the embedded VNWA Virtual Demo Device where you can run the software just like if you had a connected VNWA hardware. This to facilitate a potential customer to a VNWA can try it out prior a decision to purchase. The only detail is that you do not enter a license code but just carry on with the installation, so I find it hard you are right on "only licensed for use with the VNWA". It supports also the N2PK VNA so that is another indication it is not linked to the use of the VNWA. There might be some remark in the licensing screen during installation with a precise definition about this issue (it is a long time since I read it). Why focus on the negative sides be positive please ? Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af Dr. David Kirkby from Kirkby Microwave Ltd Sendt: 25. september 2019 01:19 Til: [email protected] Emne: Re: [nanovna-users] on the comparisons On Tue, 24 Sep 2019 at 10:22, Kurt Poulsen <kurt@...> wrote: Hi David Kurt, There are a few issues here 1) VNWA software is closed source. 2) VNWA software only runs on Windows 3) Although the VNWA software is free, the last time I looked it was only licensed for use with the VNWA. I know Tom has never pressed this, and in fact once Tom made a change that allowed me to read in S-parameters from my LCR meter, although the VNWA software doesn¡¯t fully support the Touchstone file format. I would add the same is true of an Agilent PNA-X ????. Sonnet Lite was a free, but closed source application which has better support for Touchstone files. As an advocate of open source software, and as someone who has a dislike for Windows, I would rather an open source solution I can run on a Unix or Linux system. Dave --Dr. David Kirkby, Kirkby Microwave Ltd, drkirkby@... Telephone 01621-680100./ +44 1621 680100 Registered in England & Wales, company number 08914892. Registered office: Stokes Hall Lodge, Burnham Rd, Althorne, Chelmsford, Essex, CM3 6DT, United Kingdom |
Re: on the comparisons
Hi Erik
Ok, thank you. I have updated the Excell Kind regards Kurt -----Oprindelig meddelelse----- Fra: [email protected] <[email protected]> P? vegne af erik@... Sendt: 25. september 2019 10:24 Til: [email protected] Emne: Re: [nanovna-users] on the comparisons Kurt, Made some small changes Input tab: Paste your rectangular input file of max 1001 points directly into this tab. Check if the values are correctly spread over the columns like is shown now. If they are all in the first column use data->columns with space as delimiter to spread over the columns Calculation tab: This is where the complex values and the t-check formula are calculated . The graph will show the outcome |