Re: NanoVNA-Q firmware update 0.4.4 #nanovna-q
https://github.com/qrp73/NanoVNA-Q
By QRP RX · #7452 ·
Re: NanoVNA-Q firmware update 0.4.4 #nanovna-q
NanoVNA-Q is alternative firmware for NanoVNA-H device
By QRP RX · #7451 ·
Re: NanoVNA-Q firmware update 0.4.4 #nanovna-q
OK, I see NanoVNA-F, NanoVNA-H, plain vanilla NanoVNA, but who is NanoVNA-Q ?? Where did he come from ? The good news is, there are 23 more letters available !! 73, Dick, W1KSZ
By Dick · #7450 ·
NanoVNA-Q firmware update 0.4.4 #nanovna-q
NanoVNA-Q 0.4.4 released: https://github.com/qrp73/NanoVNA-Q/releases Added average mode which allows to reduce measurement noises. Very useful for calibration.
By QRP RX · #7449 ·
Re: Firmwares
Hi Jean, this afternoon i thought i was doing a table, i hope you thought so.
By Gyula Molnar · #7448 ·
Re: Software for Anroid
OK thanks, I will have a go with that one, I was hopping there was others. Thanks anyway, I need to play with it and see what it does. Sent from Mail ( https://go.microsoft.com/fwlink/?LinkId=550986 )
By Les Brown · #7446 ·
Software for Android
Hi all I have just got my unit and it works well but I am looking for the best software (for Ham Radio) to use on my Android phone and tablet? I have nanoVNAPartner and nanovna-saver-v0.2.0 and was
By Les Brown · #7445 ·
Re: Software for Anroid
Go to the Play store and search for nanovna. You'll find the only app available - but make sure your android device supports USB OTG and you have an OTG cable.
By Larry Rothman · #7444 ·
Re: Playing with my nano
I built a fixture to make it easy to test through-hole and SMT parts https://github.com/profdc9/VNA/tree/master/fixture You can use the ZIF socket with resistance as calibration standards and it works
By Daniel Marks · #7442 ·
Updated document
Hi All I have update my calibration document for male and female calibration. I have added a set of screen copies how to set the calibrations for NanoVNA-saver to compensate for the problem Rune made
By Kurt Poulsen · #7441 ·
Re: NanoVNA connection to iPad?
Yes, hardware support is prerequisite Sadly, iOS web browsers do not support webUSB apps, and there are seemingly no free VNA apps, and I find only one commercial (FieldFox) app
By Oristo · #7440 ·
Re: NanoVNA connection to iPad?
What app would Sam run on the iPad though?I can only think of a terminal to access the console commands. Are there VNA iPad apps? (Haven't looked)
By Larry Rothman · #7439 ·
Re: nanoVNA Partner #nanovna_partner
Hi Luis, there's currently no way to merge the two pieces of software, as NanoVNA-Saver is Open Source, and NanoVNA Partner is not. :-) Going by the screenshots, it looks like it's merely a
By Rune Broberg · #7438 ·
Re: NanoVNA-H version 0.4.0-3 compiled on November 25, 2019
Forgot to clarify, with 8 mA it has a little worse dynamic range for S11, but a little better dynamic range for S21. See screenshots taken from S2P files.
By QRP RX · #7437 ·
Re: nanoVNA Partner #nanovna_partner
Please, merge the best of nanovna_partner with the best of nanovna-saver. Make it the nanoVNA-SavingPartner!!! 73 de Luis, CT2FZI http://www.ct2fzi.net <http://goog_717545661>
By CT2FZI · #7436 ·
Re: Playing with my nano
Check under test jigs in /g/nanovna-users/wiki/Application-Notes
By Oristo · #7435 ·
Re: NanoVNA-H version 0.4.0-3 compiled on November 25, 2019
with 8 mA mode NanoVNA has a little worse dynamic range for 0-300 MHz. Here is my measurements for both cases taken on NanoVNA-Q firmware with enabled average mode. The test case is the following: 1)
By QRP RX · #7434 ·
Re: NanoVNA connection to iPad?
iOS supports OTG (using so-called camera adapter) for some device classes, but not serial. My understanding is that iOS does support serial devices via BLE.
By Oristo · #7433 ·
Re: NanoVNA-H version 0.4.0-3 compiled on November 25, 2019
I see comparable differences in resistance plots on device when not recalibrating between power changes e.g. from ~ 27 to 30 Ohms @ 496MHz for power 3 to 1; inductance changes from ~1000 to 650 pH
By Oristo · #7432 ·
Re: NanoVNA-H version 0.4.0-3 compiled on November 25, 2019
I redid the 25 ohm measurement on three power levels. Power 1,2 and 3 using a calibration done at power 1 For sure there is difference where it should not. Look at the light blue line
By Erik Kaashoek · #7431 ·