¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Re: Calibration question
When changing sweep ranges, it's always a good idea to recal. Dave - W?LEV [email protected]> wrote: -- Dave - W?LEV
By W0LEV · #40090 ·
Calibration question
I'm new to the NanoVNA H-4.? If I calibrate for SWR in the range of 144-174, and then I change the range to, say, 144-148, do I need to re calibrate? IOW, for the purposes of SWR readings, under what
By Kenneth Roberts · #40089 ·
Re: Save change to active trace
By design, slot 0 is activated on power-up, not any other slot. Yes, if you calibrate, then change trace and display options, then save calibration again, it save the currently active calibration and
By Stan Dye · #40088 ·
Re: Windows 11 & NanoVNA H4
Yes I think the nanovna firmware version needs to be somewhat recent. This capability was added a year or so ago I think. You can also get the current firmware for the H4 from DiSlord's nanovna-d
By Stan Dye · #40087 ·
Re: Windows 11 & NanoVNA H4
Stan, Thank you for your tip about the little camera icon in NanoVNA-app. Interesting. I gave it a try. Clicking on it, the pop up screenshot is there, but it updates the small screen only when I
By PE0CWK · #40086 ·
Re: Windows 11 & NanoVNA H4
Stan, Thank you for your tip about the little camera icon in NanoVNA-app. Interesting. I gave it a try. Clicking on it, the pop up screenshot is there, but it updates the small screen only when I
By PE0CWK · #40085 ·
Re: Save change to active trace
It only works for Save 0. Not for other recalls even if I have changed SWR to active trace and made Calibrate > Save. But if I make Calibrate > Calibrate > Done SWR will remain as the active trace. I
By Torbj?rn Toreson · #40084 ·
Re: Save change to active trace
Save calibration again after change trace type and settings
By DiSlord · #40083 ·
Save change to active trace
When I have made a calibration that firstly involves a SWR trace and secondly a trace for Smith, then the Smith-trace is the active trace. Is it possible to afterwards when having changed so that the
By Torbj?rn Toreson · #40082 ·
Re: Windows 11 & NanoVNA H4
Thank You Stan! I realized that I was using the original One ot Eleven app and changed to latest Dislord update from his GitHub. The new possibilities are very nice to use for presentations of
By Torbj?rn Toreson · #40081 ·
Re: Windows 11 & NanoVNA H4
Torbjorn, In nanovna-app, click the little 'camera' icon at the top of the main window. It will pop up a screenshot of the nanovna in a new window. That new window has a 'Remote" switch, toggle it on,
By Stan Dye · #40080 ·
Re: Nano VNA H-4 ver 1.2.27
Dave W0LEV, Thank you I have emailed you via your ARRL email address.
By Phil Brown · #40079 ·
Re: Nano VNA H-4 ver 1.2.27
Phil and John, The NanoVNA is an excellent tool for measuring the inductance and capacitance of components. The S11 shunt method using CH0 (port 1) works well for most measurements. In order to get
By Roger Need · #40078 ·
Re: Windows 11 & NanoVNA H4
Roger, Can You evolve how that is done. I have never seen that possibility with NanoVNA-App. Regards/Torbjorn
By Torbj?rn Toreson · #40077 ·
Re: Nano VNA H-4 ver 1.2.27
How do you measure a coax with my nanovna
By Phillip Lewis · #40076 ·
Re: Nano VNA H-4 ver 1.2.27
Once you have calibrated you setup at the measurement plane including any fixtures, the following may help you (I've got the VNA in front of me as I write so I'll go through the steps). To measure
By W0LEV · #40075 ·
Re: Nano VNA H-4 ver 1.2.27
Hi Stan, I gratefully will accept your kind offer of help. Thank you and I am not in a hurry. zapel406@...
By Phil Brown · #40074 ·
Re: Nano VNA H-4 ver 1.2.27
Hi Dean and everyone who gave an answer firstly thank you. Yes I am using Nano Saver on my laptop, yes I am aware of how to calibrate and the importance of measuring at the plane, yes I have made jigs
By Phil Brown · #40073 ·
Re: Nano VNA H-4 ver 1.2.27
Phil, Even if you know how to use the VNA, measuring the QMX lowpass filters is tricky. I have done it a few times and can help you, but it would have to wait until Monday since I currently have
By Stan Dye · #40072 ·
Re: Nano VNA H-4 ver 1.2.27
I second this! After you learn to properly calibrate the VNA in your test environment, look up YouTube videos on the Smith Chart, there are many. The chart will map resistance, inductance, and
By Matthew Rapaport · #40071 ·