Re: Broken S-A-A v2 ?
not sure how quoting works here but @Larry Rothman From the link above. I installed the v2.2 firmware. The one that is not sold anymore. Problem is still the same Then I installed one above it (v2
By
jorksx@...
·
#24736
·
|
Re: Firmware Updates for the SAA-2N
Valinire in previous post said to use the following for the s-a-a-2 One is the comm port and the other is the firmware Here is the links
By
K8HTB
·
#24735
·
|
Re: Broken S-A-A v2 ?
Config-version only displays the version of FW you installed into the device. If you installed plus FW into a non-plus device, you will see 'plus' on the version screen. So - you need to install the
By
Larry Rothman
·
#24734
·
|
Re: Broken S-A-A v2 ?
Config - Version says NanoVNA v2 Plus. I just tested ALL the firmwares listed on that site I linked. 2 of them did not work at all, 2 were super slow and rest were working but still with my problem.
By
jorksx@...
·
#24733
·
|
Re: Broken S-A-A v2 ?
Are you sure you have a plus version? The firmware for regular V2 and V2Plus is different (but work, not good work).
By
DiSlord
·
#24732
·
|
Re: Broken S-A-A v2 ?
I tried with those sma calibration things and I also calibred with 50ohm resistor I also tried open so without any connection short, I shorted sma center to threads and load was 50ohm resistor
By
jorksx@...
·
#24731
·
|
Re: Broken S-A-A v2 ?
There is a similar effect when you upload the plus version firmware to the non plus hardware.
By
btomek@...
·
#24730
·
|
Re: Firmware Updates for the SAA-2N
The saa-2n doesn't use dfu for flashing.? Please search the forum messages for: SAA-2N firmware? And you should find the info you need.? Please remember that this forum is primarily for the NanoVNA
By
Larry Rothman
·
#24729
·
|
Firmware Updates for the SAA-2N
So I tried following the procedure in the absolute beginner guide in order to update the firmware on my SAA-2N. I noticed when connecting it to my PC it shows up as USB Serial Device (COM3) and when I
By
Chris Pohlad-Thomas
·
#24728
·
|
Re: Adapters
I always calibrate with as many connections and cables attached as I can to eliminate insertion loss. I never considered delay as a factor, which I will now have to research.
By
lobos305@...
·
#24727
·
|
Re: Broken S-A-A v2 ?
It looks like the calibration parts and or a cable or 2 might be defective.? This has tripped-up users in the past with the same display output.? Check all your call components.? On Tue., 14 Sep.
By
Larry Rothman
·
#24726
·
|
Re: Broken S-A-A v2 ?
I would also agree on checking connections. when i ever have not a tight connection to whatever I am testing I get that birds nest mess of lines also. Joe WB9SBD
By
Joe WB9SBD
·
#24725
·
|
Re: Broken S-A-A v2 ?
Also check what version of firmware you have. Current version is 1.0.69 De K8HTB Joe
By
K8HTB
·
#24724
·
|
Re: Broken S-A-A v2 ?
Not sure what frequency you are measuring but first do a reset all. In menu buttons. Set the stimulus 1 MHz to 10 MHz? just for some low hf range. On the s-a-a-2 my SAA2 port zero is the bottom
By
K8HTB
·
#24723
·
|
Re: Broken S-A-A v2 ?
Yea. Reseted all before ecah cal. Did cal reset and tried reset all and started all over...
By
jorksx@...
·
#24722
·
|
Re: Broken S-A-A v2 ?
Did you do a reset before each cal? Dave - W?LEV -- *Dave - W?LEV* *Just Let Darwin Work*
By
W0LEV
·
#24721
·
|
Broken S-A-A v2 ?
Hello. Got my hand on this nanovna v2 plus(?) Frist time turned it on got ALOT of traces and no idea what to do. After some tutorials I realased that it might be broken / bricked. As you can see from
By
jorksx@...
·
#24720
·
|
Re: Adapters
Sorry Larry, I had to run out for an appointment and forgot to snip message. Mike N2MS
By
Mike N2MS
·
#24719
·
|
Re: Measuring crystal parameters with classic NanoVNA?
Thanks, I've updated mine and it works great as well! M
By
Mario Vano AE0GL
·
#24718
·
|
Re: Measuring crystal parameters with classic NanoVNA?
Thanks to all!
By
Mario Vano AE0GL
·
#24717
·
|