Jim Hughen
?
toggle quoted message
Show quoted text
In eeschema, choose the 'X' function in the right
hand tool menu.
Then place the 'X' on a pin to declare it a "no
connect".
?
... Jim H.
?
|
Dio Brando
Yes, this's works prefectly instead the "pin properties" one. This is why I thinked to a bug. Thanks anyway.
toggle quoted message
Show quoted text
-- Rollo On 21/02/2011 16:39, Jim Hughen wrote:
|
Jim Hughen
?
toggle quoted message
Show quoted text
Sorry about that.
?
Maybe this will help:
?? The "pin properties" within the module
definition says "There is nothing connected INSIDE of the module."
?? The "No Connect" on the schematic says
"There is no trace or net connected?to the OUTSIDE of?the
module."
?? So the "pin properties" setting of
"not connected" is different than a "No Connect".
?
...Jim H.
?
|
Dio Brando
On 21/02/2011 22:19, Jim Hughen wrote:
Many thanks for the explanation and your time! -- Dio |