"Pin properties" men? bug?


Dio Brando
 

Anyone found it? In the eeschema manual I didn't find the "not connected" options (maybe it's not updated yet).


--
Dio


Jim Hughen
 

?
In eeschema, choose the 'X' function in the right hand tool menu.
Then place the 'X' on a pin to declare it a "no connect".
?
... Jim H.
?

----- Original Message -----
From: Dio Brando
Sent: Saturday, February 19, 2011 4:10 AM
Subject: [kicad-users] Re: "Pin properties" men? bug?

?

Anyone found it? In the eeschema manual I didn't find the "not
connected" options (maybe it's not updated yet).

--
Dio


Dio Brando
 

Yes, this's works prefectly instead the "pin properties" one. This is why I thinked to a bug. Thanks anyway.

--
Rollo

On 21/02/2011 16:39, Jim Hughen wrote:


?

In eeschema, choose the 'X' function in the right hand tool menu.
Then place the 'X' on a pin to declare it a "no connect".
... Jim H.

----- Original Message -----
*From:* Dio Brando <mailto:diobrando@...>
*To:* kicad-users@... <mailto:kicad-users@...>
*Sent:* Saturday, February 19, 2011 4:10 AM
*Subject:* [kicad-users] Re: "Pin properties" men bug?

Anyone found it? In the eeschema manual I didn't find the "not
connected" options (maybe it's not updated yet).

--
Dio


Jim Hughen
 

?
Sorry about that.
?
Maybe this will help:
?? The "pin properties" within the module definition says "There is nothing connected INSIDE of the module."
?? The "No Connect" on the schematic says "There is no trace or net connected?to the OUTSIDE of?the module."
?? So the "pin properties" setting of "not connected" is different than a "No Connect".
?
...Jim H.
?

----- Original Message -----
From: Dio Brando
Sent: Monday, February 21, 2011 1:54 PM
Subject: Re: [kicad-users] Re: "Pin properties" men? bug?

?

Yes, this's works prefectly instead the "pin properties" one. This is
why I thinked to a bug. Thanks anyway.

--
Rollo

On 21/02/2011 16:39, Jim Hughen wrote:
>
>
> ?
>
> In eeschema, choose the 'X' function in the right hand tool menu.
> Then place the 'X' on a pin to declare it a "no connect".
> ... Jim H.
>
> ----- Original Message -----
> *From:* Dio Brando diobrando@...>
> *To:* kicad-users@... kicad-users@...>
> *Sent:* Saturday, February 19, 2011 4:10 AM
> *Subject:* [kicad-users] Re: "Pin properties" men? bug?
>
> Anyone found it? In the eeschema manual I didn't find the "not
> connected" options (maybe it's not updated yet).
>
> --
> Dio
>
>


Dio Brando
 

On 21/02/2011 22:19, Jim Hughen wrote:

Maybe this will help:
The "pin properties" within the module definition says "There is nothing
connected INSIDE of the module."
The "No Connect" on the schematic says "There is no trace or net
connected to the OUTSIDE of the module."
So the "pin properties" setting of "not connected" is different than a
"No Connect".
...Jim H.
Many thanks for the explanation and your time!

--
Dio