¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: 3 x YC-156's vs 8281

pentalab
 

--- In ham_amplifiers@..., "Peter Voelpel" <df3kv@...>
wrote:



________________________________

From: ham_amplifiers@...
[mailto:ham_amplifiers@...]
On Behalf Of pentalab


### These YC-156/YC-179's.. with their almost 19db of gain..
RICH SEZ..... Eimac says the gain is 14.2db at 6kV.
### Who cares what Eimac sez ?

### fact is.. on a YC-156/YC-179.. folks are getting a power gain
of 50-60 = 17-17.78 db. 200 w of drive and 7200 V under load

I do not see the almost 19dbs here...
When you raise anode voltage gain will be higher with any tube.
A lot of YC-156 amps are running in Germany, none does more then
17dbs of gain at 6KV

### With low drive.. and 6500-7300 V under load.. Plate Z is up...
gain goes up. Drive em harder... gain goes down.

### Notice how Eimac sez u need 450 w to drive a 3x3 ? That put
hundreds of guys off using that tube for yrs on end. Folks didn't
like the 500 ma zsac either. Turns out with 50 w of drive = 1.5
kw out. 200 w of drive = 5200W out....

Eimac did not say you need 450W to drive a 3x3 to 1,5KW...
### I never said they did. That's what Eimac quotes for full
bore output.


When you use the constant curves of the Eimac data sheet you see
all this. With 4,8KV at the anode you need 280-300W drive for 5,2KW
out(we run 4 monoband amps with that tube).

#### So what did u do to have less gain with 4.8 kv under load ?
You should be able to get at least 5 kw with 200 w of drive. [new
tube] . What Z did u design the tuned input around ?? I'm
finding that a lot of the overall eff has to do with the way the
tuned input is configured... like where the C2 cap actually sits.
How the C2 cap is actually connected to the socket... whether u
introduce a Z bump bwetween C2 and the socket.... and what the Q
of the tuned input is. Run the Q too high.. and power out of the
tuned input drops on the high bands. PI/PI-L on the output
side will change things too. On one of the 4-1000 amps I had
yrs ago, with a roller in it... I started off with the Q on the
high side... then kept increasing the roller uh...[lowering the Q]..
kept retweaking the tune/load caps... and watched the wattmeter
keep going up up up every time... until wattmeter flattens out...
IE:.. decrease Q until you no longer see an increase in power out.

### I gave up on PI-L networks on the output side. I see no
advantage to em at all. The spreadsheets spit out bizzare
values for the most part.. on some bands.. like sky high uh
required on 160m... and real low C1 valus on high bands. I'm not
interested in harmonic suppression... I don't run a MM set up
either. Mono band ant's are not likely to radiate on their 2nd
harmonic anyway [sky high z match]... and most PI-nets have plenty
of 3rd harmonic suppression.




### Imo... I use their number's, as a guidline. Once an amp is
built around their tube.. say a YC-156... and u talk to other
builder's... you get a feel for what kind of zsac is really
needed PER mode...

I rather do my own measurements. Other builders talk like
fishermen, when I visit them I see and measure the
truth ;-)
### partially agreed. I just like to know aprx what every one
else's results are b4 embarking on something. Case in
point..... obtain several same type tubes... and the idle
current, for a given plate v can easily be all over the map. I have
seen this b4... with new Eimac tubes, all built around the same
time period too. Switch to Svetlana....things change a bit. Try
used tubes, and your results could be anywhere. At least with a
spanky new tube/rebuild... you can safely asume that's as good as it
gets.

### I really don't trust any of these Bird/Coaxial Dynamics slugs
either. W7RF tried 2 doz brand new 2.5 kw slugs... and readings
are all over the map. I ordered identical slugs for myself and a
friend... and even they were different.

### Has anybody tried one of the new 20 kw wattmeter's from Array
solutions yet ?

Later... Jim VE7RF

73
Peter


Re: 3 x YC-156's vs 8281

Tony King - W4ZT
 

pentalab wrote:
<snip>
### These YC-156/YC-179's.. with their almost 19db of gain..
RICH SEZ..... Eimac says the gain is 14.2db at 6kV.
### Who cares what Eimac sez ? They either don't build amps around these various tubes... or quote.. "estimated" or "calculated" specs. Imo... Eimac makes a tube.... it's up to the end user to make it work right. ### fact is.. on a YC-156/YC-179.. folks are getting a power gain of 50-60 = 17-17.78 db. 200 w of drive and 7200 V under load = 12 k out. 10 k out, with lower plate V. So I guess Eimac's '14.2db' is out to lunch.... who cares... just run the tube the way u see fit.
<snip>
We've seen 17 to 19 dB gain from the 156/179 with 5500 to 6000 Volts on the plate and that's in more than one amp so it's not a fluke.

73, Tony W4ZT


Re: 3 x YC-156's vs 8281

pentalab
 

--- In ham_amplifiers@..., "zerobeat40" <zerobeat40@...>
wrote:

--- In ham_amplifiers@..., R L Measures <r@...> wrote:


On Oct 29, 2006, at 5:54 AM, pentalab wrote:

---
### well maybe not too stupid. 3 x YC-156's can be had for
$1100.00 vs huge bux for a 4 x 15.[plus socket]
RICH SEZ... What is Svetlana's price for an 8281?
##### They are now $1995.00 socket is $395.00... both svetlana
brand. The Eimac version of both will make u gag.

Last 8281 I bought brand new set me back about $1050, and I think I
had to add a socket. And, the tube's pushing good and hard at 20k,
while a trio of YC-156's is loafing at 30K. Remember, a YC-156 is
actually a 3CX15,000B7 with a smaller cooler.
### agreed. YC-156/YC-179's are everywhere.. and no [failure
prone} socket to mess with. Note to Tony King here. A buddy of
mine asked Eimac if they could take a YC-156... and put the
3CX15,000B7's cooler on it [7.5"]. Eimac said "no way". BTW...
a broadcast engineer school buddy of mine said they had several
problems with the SK-300A socket burning up on the local 100 kw
ERP FM tx here in town.[abt 18 yrs old now] No wonder Eimac
makes "emergency repair" kits for those sockets. The socket
had burned up twice.... b4 1994 [it was only 10 yrs old at that
point]




You CAN push more air (put the amp in another room, please) and run
them quite harder. I have a push-pull broadband pair of YC-156s
here, runs 2MHz to 40MHz braodband, for EMC measurements, driving a
TEM cell. 30kW CW not a problem. Not pushing ANY of the tube's I
or V limits, and with enough air, I keep the seals below 250C.


### These YC-156/YC-179's.. with their almost 19db of gain..
Eimac says the gain is 14.2db at 6kV.
You have to read all the conditions of that gain spec. 14.2dB is
correct with a 600 ohm load-line. That will give you 24kW PER
TUBE. If you're getting 30-35kW from three tubes, you're running
more like a 1500 ohm load line per tube. At a higher RL, the tube
exhibits more gain.

### agreed.


Also, that 14.2dB is conservative - it's into compression at
that point. Cleanly, it's another dB, then add a few more for the
higher RL.
### agreed. Most builder's appear to be getting 17 to 17.8 db
with a single tube.. running 6500 V - 7200 V ..under load. With
higher ratio's of plate load Z to input Z... gain goes UP.. as u
noted.

### 12 k out with 200 w of drive is quite common. IMO... a
lot simpler than mucking about with a 4x10, regulated screen +
bias supplies, roller's across the input globar..+ step up 9:1
trifilars, neutralizing the entire amp, megabuck sockets, etc.
A good used YC-156[$300-$400] beats a new 4x10 + socket any day.
Something to be said for simplicity. Just whack one hole in the
chassis... done. Round up a 10 kva-120 lb 4800 V hypersil pole
pig for very little.. and there's ur 6800 V no load HV supply.




Besides, nobody who's actually designing an amp depends on the
"typical application" data to predict performance.
### agreed.

You calculate gain from the characteristic curves.
### agreed.



At 20kW output and 6.5kV anode, I see YC-156s typically running
at 17dB gain.

### see my previous notes. Depending on used tube condx, ops are
reporting anywhere between 17 to almost 19db of gain.



Most of my experience in broadcasting with them was with the
3CX15,000B7 version, but they work the same...the YC-156 just needs
to be blasted with lots more air.

are
the 4-1000 for the new milenium... quick, where's that pole
pig ?

### I'm serious....
Serious people look at the mfg's spec sheet instead of
speculating.

Exactamundo. The grounded-grid curves for the YC-156 will predict
all the figures he gave. You just have to know how to use them, and
that's happily explained in "Care and Feeding."
### agreed... like zsac for a given plate V, grid current, plate
current, etc. Heck, I still have the origional Eimac... "tube
performance computer" ! [clear plastic overlay device, when
doing load lines] ... still works, still use it.

Later.... Jim VE7RF


cheers, Jim


R L Measures, AG6K, 805.386.3734
r@..., , rlm@, www.somis.org


Re: 3 x YC-156's vs 8281

Peter Voelpel
 

________________________________

From: ham_amplifiers@... [mailto:ham_amplifiers@...]
On Behalf Of pentalab


### These YC-156/YC-179's.. with their almost 19db of gain..
RICH SEZ..... Eimac says the gain is 14.2db at 6kV.
### Who cares what Eimac sez ?

### fact is.. on a YC-156/YC-179.. folks are getting a power gain
of 50-60 = 17-17.78 db. 200 w of drive and 7200 V under load

I do not see the almost 19dbs here...
When you raise anode voltage gain will be higher with any tube.
A lot of YC-156 amps are running in Germany, none does more then 17dbs of
gain at 6KV

### Notice how Eimac sez u need 450 w to drive a 3x3 ? That put
hundreds of guys off using that tube for yrs on end. Folks didn't
like the 500 ma zsac either. Turns out with 50 w of drive = 1.5
kw out. 200 w of drive = 5200W out....

Eimac did not say you need 450W to drive a 3x3 to 1,5KW...
When you use the constant curves of the Eimac data sheet you see all this.
With 4,8KV at the anode you need 280-300W drive for 5,2KW out(we run 4
monoband amps with that tube).

### Imo... I use their number's, as a guidline. Once an amp is built
around their tube.. say a YC-156... and u talk to other builder's...
you get a feel for what kind of zsac is really
needed PER mode...

I rather do my own measurements.
Other builders talk like fishermen, when I visit them I see and measure the
truth ;-)

73
Peter


Re: submounted tubes vs normal mount vs elevated on a pedestal

Tony King - W4ZT
 

Tony King - W4ZT wrote:
<snip>
I will measure this tomorrow and report back the difference between the
measured anode to grid capacitance unmounted and sub-mounted.
Regarding YC-156/179 sub-mounted capacitance.

I measured this today on a YC-179. Sitting on the counter top grid to anode measured 40.85 pF. Sub-mounted in a chassis it measured 44.67 pF.

73, Tony W4ZT


Re: HV Fuses: Manufactures/brands in Europe ?

pentalab
 

--- In ham_amplifiers@..., FRANCIS CARCIA <carcia@...>
wrote:

a friend and I had the same problem once with a qro rig and went
with two tall insulated standoffs with a singls strand of RG8
shield. Smaller wire would fuse at lower currents. gfz
## I have used the exact same deal... used one single strand from
the multi strands in the Belden 10 kv test prod wire. One day it
blew. [op error]... and blew right away [no load] when replaced.

### Stuck my dvm between chassis and top of each insulator [all
HV wiring removed at each end, no fuse wire]... and the output
insulator read a DEAD SHORT ! How can a 1.75" tall insulator
read a dead short? Got in with a dentist mirror.... and on the
back side.... it had vapour deposited top to bottom ! Scrubbed
it off... all was well. If that had been the INPUT insulator,,, I
could have easily smoked the 3 A diodes, or something else in the
supply. Started using sandilled HV fuses after that.[ I now also
use nothing but 6A10 diodes... cheap. 1 kv-6A CCS 400 A surge,
exactly double the diam of a 1N5408... same ga wires out each
end... and same body length. You can retrofit a 1N5408 with a 6A10
very easily... they run like warm with 2 A CCS DC through em in a
test jig, a 1N5408 runs look warm with 1 A in same test jig].

### Now my buddy ate up his supply of sandfilled fuses.... so in
desperation one night.... soldered a single strand of real small
ga wire across a blown sandfilled fuse.... THEN wrapped it
with scotch 77 tape ! Now this works slick, cuz when it
blows... NO vapour deposit flying about. This way u can RE-
USE em, if needed... over and over again.

## A 2-6" long piece of round ceramic in 2 x clips, would do
exactly the same thing.... then tape the exposed fuse wire.

Later... Jim VE7RF


Re: 3 x YC-156's vs 8281

pentalab
 

--- In ham_amplifiers@..., R L Measures <r@...> wrote:
. He needs a 15k or 20k!

RICH SEZ.... Paralleling 3 tubes triples C-feedback, and that
is
not desirable unless one is trying to build an oscillator. The
tube that is best suited for 20k - 35k out is the
8281/4cx15000A.
200w will drive one in AB1.

### So what ?
RICH SEZ... Anecdotal sure-cures don't cut the parasitic mustard.
### Anecdotal?? Tell that to the 300 guys who run the above
tubes just fine...sans suppressor. IMO... having the grids bolted
right to the chassis IS 99.99% of the stabilty secret. Semi
floated grids on a 3-500Z is just asking for trbl.

Just install a globar type suppressor in each anode
lead. As is, the single YC-156 runs just fine wtih NO
suppressor at all.. and that's with it .75pf of feed through C
to boot. The single 3CX-3000A7 runs just fine sans suppressor
with it's .6 pf of feedthrough C. The 3CX-6000A7 has just .28
pf of feedthrough C. We can probably toss the suppressor on
that amp as well. At this rate, we can put globar outa business.

### well maybe not too stupid. 3 x YC-156's can be had for
$1100.00 vs huge bux for a 4 x 15.[plus socket]
RICH SEZ... What is Svetlana's price for an 8281?
### RF parts wants $1995.00 for a Svetlana 4x15.... PLUS
another $395.00 for a svetlana SK-300A socket. .. so $2400.00
in total. You can get 2 x new Eimac YC-243's for slightly less...
and crank an easy 30 k out the back door.... and cool em way
easier.

### Check the air specs on a 3x 15 or a 4 x 15.... horrendous.
Something like 840 cfm @ 6.4" h20. I saw a FM broadcast Tx
with 2 x 3x15's.... it had a 5 HP- 3 phase blower.... just to
cool em. A lousy analogy woul be like trying to stuff 100 cfm
through a key hole.


### These YC-156/YC-179's.. with their almost 19db of gain..
RICH SEZ..... Eimac says the gain is 14.2db at 6kV.
### Who cares what Eimac sez ? They either don't build amps
around these various tubes... or quote.. "estimated"
or "calculated" specs. Imo... Eimac makes a tube.... it's up
to the end user to make it work right.

### fact is.. on a YC-156/YC-179.. folks are getting a power gain
of 50-60 = 17-17.78 db. 200 w of drive and 7200 V under load =
12 k out. 10 k out, with lower plate V. So I guess
Eimac's '14.2db' is out to lunch.... who cares... just run the
tube the way u see fit.




### Notice how Eimac sez u need 450 w to drive a 3x3 ? That put
hundreds of guys off using that tube for yrs on end. Folks didn't
like the 500 ma zsac either. Turns out with 50 w of drive = 1.5
kw out. 200 w of drive = 5200W out.... and that's with just
4.8 kv under load. The tube is squeaky clean with 150 ma of zsac.
Then along comes the 11m ops... running 8 kv under load.



are
the 4-1000 for the new milenium... quick, where's that pole
pig ?

### I'm serious....
RICH SEZ... Serious people look at the mfg's spec sheet instead of
speculating.

### So where's all the missing specs for a 3CX-6000A7 in AB-2,
GG ??? Eimac just gives us FM Class C broadcast specs.... turns
out they also quote running ZERO bias. Obviously, with zero
bias... it's in AB-2... NOT class C. They are also quoting near
impossible efficiency numbers... when figuring out their 'typ op
condx' and take plate v x plate I... and their "estimated
output"... and start coming up with ridiculous eff numbers....
meanwhile with zero bias... the tube(s) are more like pushing
Class A region... and cooking on idle.

Eimac to this day can't tell you what the input Z on that tube
is. And it's not 6 kw anode diss.... it's an easy 9.7 kw. They
can't even tell u what the grid current is gonna be.... nor the
specs on the 3x6 for imd either.... turns out the 3x3 and 3x6
are the best imd triodes going. Check out their Blue 'erata
sheet'... that comes with their latest catalog.... doz's of
typo's and specs wrong.... plus a bunch more I found... that are
not listed. ..go figure.

Imo... I use their number's, as a guidline. Once an amp is built
around their tube.. say a YC-156... and u talk to other builder's...
you get a feel for what kind of zsac is really
needed PER mode... what to expect with XXX plate V... and ditto
with drive levels.... then you end up with ur own "typ op condx" +
hence... find an optimum set of condx to run the tube(s) at.

Later......... Jim VE7RF


cheers, Jim


R L Measures, AG6K, 805.386.3734
r@..., , rlm@..., www.somis.org


Re: HV Fuses: Manufactures/brands in Europe ?

FRANCIS CARCIA
 

a friend and?I had the same problem once with a qro rig and went with two tall insulated standoffs with a singls strand of RG8 shield. Smaller wire would fuse at lower currents. gfz

pentalab wrote:

--- In ham_amplifiers@yahoogroups.com, R L Measures wrote:
>
>
> On Oct 30, 2006, at 1:08 AM, Frank Goenninger wrote:
>
> > Hi all:
> >
> > I am about to finish my HV power supply. One thing missing still
is
> > an appropriate HV fuse to be put between C bank and glitch R.
While
> > closely examining the pictures in the photos section of this
group I
> > couldn't find any European manufacturer or distributor of HV
fuses.
> >
> > I found SIBA () - but they do provide fuses for
> > even "bigger" applications... I'd need something suitable for
the 3,5
> > kV / 3 A coming out of my 300 F C bank...
> >
> > Any suggestions? Thx for feedback!
>
>RICH SEZ.... Hello, Frank == A HV fuse in the secondary does not
protect the HV- transformer any better than a circuit breaker in
the primary. cheerz

### What about protecting everything else ???? Short the B+ to
the chassis/ anywhere... and when comparing a fast HV fuse vs the
fastest magnetic hydraulic breaker in the 240 V pri.... the
difference is blatantly obvious. Been there.. done that. The only
thing faster than the fastest breaker is... "rectifier and
semiconductor" pri fuses... available up to sevral hundred amps.
These fuses can be used to supplement a slow breaker.... OR can be
used in cases where the breaker rating is way too high to start
with. [eg: multiple sec HV taps on a plate xfmr... where u want
to run say a single 3CX-800A7 on 6m one day... and 15 kw out the
next day, with a different amp of course.]

### Primary AC protection is way too slow imo. Since my xfmr has
loads of sec taps... I use it at different voltages... so a 100 A
breaker in the primary is too big for some applications. Another
Fix is to use a pair of 50 A double pole breaker's.... and
parallel each pair. By removing the tie-bar between em.... for
50 A operation... one pole on each breaker is shut off.

### If u are gonna parallel a 2 x pole 50A breaker, so it
handles 100 A... you have to do it right.... enter on one
corner...and exit diagonally on the output. Then the current
will split 50-50 on the poles.

### This scheme also works on 3 pole breaker's. [which use 2 x
tie bars per breaker] You can parallel all 3 x poles..... and by
removing the 2 x tie bars on each breaker ...... you can have a
50-100-150 A choice. 2 x such assys are always required.... one
per hot leg on a NA single phase, 240 v circuit.

## Bottom line is.... when a HV fuse open up... nothing happens..
no big deal. They are extremely fast under fault conditions...
like <2 msecs.

Later... Jim VE7RF

> >
> > 73 Frank DG1SBG
> > ...
> >
>
> R L Measures, AG6K, 805.386.3734
> r@..., , rlm@..., www.somis.org
>



Re: HV Fuses: Manufactures/brands in Europe ?

FRANCIS CARCIA
 

speaking of fuse clips. do any of you guys know where?I can get some big clips for fixed vacuum caps like used in the BC610 padder cap. I need to add a padder to my antenna tuner for 160 meters. I think the end of the cap contact is about 3/4 inch od.

Frank Goenninger wrote:


Am 30.10.2006 um 19:46 schrieb pentalab:
> #### SSON [surplus sales of nebraska] has tons of Buss HV
> fuses. The HVU-3 is what I use. [rated at 3A @ 5 kv AC]
> These are 13/16" diam on the ends, and fit standard 3/4" fuse
> clips. The fuse itself is 13/16" diam x 5" long. They have the
> 3/4" clips too... in 2 x diff styles.... I use the slightly better
> ones... with the end retainers. That way, once inserted... they
> CAN'T slide out. Good, cause mine are mounted vertically in
> several of my many HV supplies.
;-) Worth to remember when choosing to put them vertically.
>
> ### You can still get em new... on Cooper Bussman's
> website ,buried under HV fuses. The HVU series above is
> sandfilled, u can also get em without the sand..... and a lower max
> interupting current rating. The new ones all have ceramic bodies,
> these surplus ones all have glass bodies.
Just looked on the UK web site of Cooper Bussman and found a German
distributor (a mere 100 km away from where I live. Good!) - Thanks!

>
> ### The 120mm long ones available in EU should also work. I'd
> place any HV fuse BEFORE the glitch R, not after.... just in case
> the glitch R comes apart... and touches the chassis/metal. I
> also insert a 2nd HV fuse [in one leg only on a single phase xfmr]
> between xfmr sec... and diode board.

Yes, that's what I had in mind, too. Although the SKN3F20/08 diodes I
use are of the more rugged type... ;-)
>
> later... Jim VE7RF

Thanks again!

73, Frank DG1SBG



Re: HV Fuses: Manufactures/brands in Europe ?

Frank Goenninger
 

Am 30.10.2006 um 19:46 schrieb pentalab:
#### SSON [surplus sales of nebraska] has tons of Buss HV
fuses. The HVU-3 is what I use. [rated at 3A @ 5 kv AC]
These are 13/16" diam on the ends, and fit standard 3/4" fuse
clips. The fuse itself is 13/16" diam x 5" long. They have the
3/4" clips too... in 2 x diff styles.... I use the slightly better
ones... with the end retainers. That way, once inserted... they
CAN'T slide out. Good, cause mine are mounted vertically in
several of my many HV supplies.
;-) Worth to remember when choosing to put them vertically.

### You can still get em new... on Cooper Bussman's
website ,buried under HV fuses. The HVU series above is
sandfilled, u can also get em without the sand..... and a lower max
interupting current rating. The new ones all have ceramic bodies,
these surplus ones all have glass bodies.
Just looked on the UK web site of Cooper Bussman and found a German distributor (a mere 100 km away from where I live. Good!) - Thanks!


### The 120mm long ones available in EU should also work. I'd
place any HV fuse BEFORE the glitch R, not after.... just in case
the glitch R comes apart... and touches the chassis/metal. I
also insert a 2nd HV fuse [in one leg only on a single phase xfmr]
between xfmr sec... and diode board.
Yes, that's what I had in mind, too. Although the SKN3F20/08 diodes I use are of the more rugged type... ;-)

later... Jim VE7RF
Thanks again!

73, Frank DG1SBG


Re: HV Fuses: Manufactures/brands in Europe ?

pentalab
 

--- In ham_amplifiers@..., R L Measures <r@...> wrote:


On Oct 30, 2006, at 1:08 AM, Frank Goenninger wrote:

Hi all:

I am about to finish my HV power supply. One thing missing still
is
an appropriate HV fuse to be put between C bank and glitch R.
While
closely examining the pictures in the photos section of this
group I
couldn't find any European manufacturer or distributor of HV
fuses.

I found SIBA () - but they do provide fuses for
even "bigger" applications... I'd need something suitable for
the 3,5
kV / 3 A coming out of my 300 ?F C bank...

Any suggestions? Thx for feedback!
RICH SEZ.... Hello, Frank == A HV fuse in the secondary does not
protect the HV- transformer any better than a circuit breaker in
the primary. cheerz

### What about protecting everything else ???? Short the B+ to
the chassis/ anywhere... and when comparing a fast HV fuse vs the
fastest magnetic hydraulic breaker in the 240 V pri.... the
difference is blatantly obvious. Been there.. done that. The only
thing faster than the fastest breaker is... "rectifier and
semiconductor" pri fuses... available up to sevral hundred amps.
These fuses can be used to supplement a slow breaker.... OR can be
used in cases where the breaker rating is way too high to start
with. [eg: multiple sec HV taps on a plate xfmr... where u want
to run say a single 3CX-800A7 on 6m one day... and 15 kw out the
next day, with a different amp of course.]



### Primary AC protection is way too slow imo. Since my xfmr has
loads of sec taps... I use it at different voltages... so a 100 A
breaker in the primary is too big for some applications. Another
Fix is to use a pair of 50 A double pole breaker's.... and
parallel each pair. By removing the tie-bar between em.... for
50 A operation... one pole on each breaker is shut off.

### If u are gonna parallel a 2 x pole 50A breaker, so it
handles 100 A... you have to do it right.... enter on one
corner...and exit diagonally on the output. Then the current
will split 50-50 on the poles.

### This scheme also works on 3 pole breaker's. [which use 2 x
tie bars per breaker] You can parallel all 3 x poles..... and by
removing the 2 x tie bars on each breaker ...... you can have a
50-100-150 A choice. 2 x such assys are always required.... one
per hot leg on a NA single phase, 240 v circuit.

## Bottom line is.... when a HV fuse open up... nothing happens..
no big deal. They are extremely fast under fault conditions...
like <2 msecs.

Later... Jim VE7RF






73 Frank DG1SBG
...
R L Measures, AG6K, 805.386.3734
r@..., , rlm@..., www.somis.org


Re: 3 x YC-156's vs 8281

zerobeat40
 

Forget the link to the datasheet:



The only thing I have against the YC-156 is the noise...damn, they're
loud, if you're wanting to run power and keep 'em cool.


Re: 3 x YC-156's vs 8281

zerobeat40
 

--- In ham_amplifiers@..., R L Measures <r@...> wrote:


On Oct 29, 2006, at 5:54 AM, pentalab wrote:

--- In ham_amplifiers@..., R L Measures <r@...> wrote:


On Oct 29, 2006, at 2:45 AM, pentalab wrote:

--- In ham_amplifiers@..., Tony King - W4ZT <w4zt-
060920@> wrote:

Pentalab wrote:
---
### well maybe not too stupid. 3 x YC-156's can be had for
$1100.00 vs huge bux for a 4 x 15.[plus socket]
What is Svetlana's price for an 8281?
Last 8281 I bought brand new set me back about $1050, and I think I
had to add a socket. And, the tube's pushing good and hard at 20k,
while a trio of YC-156's is loafing at 30K. Remember, a YC-156 is
actually a 3CX15,000B7 with a smaller cooler. You CAN push more air
(put the amp in another room, please) and run them quite harder. I
have a push-pull broadband pair of YC-156s here, runs 2MHz to 40MHz
braodband, for EMC measurements, driving a TEM cell. 30kW CW not a
problem. Not pushing ANY of the tube's I or V limits, and with enough
air, I keep the seals below 250C.


### These YC-156/YC-179's.. with their almost 19db of gain..
Eimac says the gain is 14.2db at 6kV.
You have to read all the conditions of that gain spec. 14.2dB is
correct with a 600 ohm load-line. That will give you 24kW PER TUBE.
If you're getting 30-35kW from three tubes, you're running more like a
1500 ohm load line per tube. At a higher RL, the tube exhibits more
gain. Also, that 14.2dB is conservative - it's into compression at
that point. Cleanly, it's another dB, then add a few more for the
higher RL.

Besides, nobody who's actually designing an amp depends on the
"typical application" data to predict performance. You calculate gain
from the characteristic curves. At 20kW output and 6.5kV anode, I see
YC-156s typically running at 17dB gain. Most of my experience in
broadcasting with them was with the 3CX15,000B7 version, but they work
the same...the YC-156 just needs to be blasted with lots more air.

are
the 4-1000 for the new milenium... quick, where's that pole pig ?

### I'm serious....
Serious people look at the mfg's spec sheet instead of speculating.
Exactamundo. The grounded-grid curves for the YC-156 will predict all
the figures he gave. You just have to know how to use them, and
that's happily explained in "Care and Feeding."


cheers, Jim


R L Measures, AG6K, 805.386.3734
r@..., , rlm@..., www.somis.org


Re: HV Fuses: Manufactures/brands in Europe ?

pentalab
 

--- In ham_amplifiers@..., Frank Goenninger <frgo@...>
wrote:

Hi all:

I am about to finish my HV power supply. One thing missing still
is
an appropriate HV fuse to be put between C bank and glitch R.
While
closely examining the pictures in the photos section of this group
I
couldn't find any European manufacturer or distributor of HV fuses.

I found SIBA () - but they do provide fuses for
even "bigger" applications... I'd need something suitable for the
3,5
kV / 3 A coming out of my 300 ?F C bank...

Any suggestions? Thx for feedback!

#### SSON [surplus sales of nebraska] has tons of Buss HV
fuses. The HVU-3 is what I use. [rated at 3A @ 5 kv AC]
These are 13/16" diam on the ends, and fit standard 3/4" fuse
clips. The fuse itself is 13/16" diam x 5" long. They have the
3/4" clips too... in 2 x diff styles.... I use the slightly better
ones... with the end retainers. That way, once inserted... they
CAN'T slide out. Good, cause mine are mounted vertically in
several of my many HV supplies.

### You can still get em new... on Cooper Bussman's
website ,buried under HV fuses. The HVU series above is
sandfilled, u can also get em without the sand..... and a lower max
interupting current rating. The new ones all have ceramic bodies,
these surplus ones all have glass bodies.

### The 120mm long ones available in EU should also work. I'd
place any HV fuse BEFORE the glitch R, not after.... just in case
the glitch R comes apart... and touches the chassis/metal. I
also insert a 2nd HV fuse [in one leg only on a single phase xfmr]
between xfmr sec... and diode board.

later... Jim VE7RF



73 Frank DG1SBG


Re: HV Fuses: Manufactures/brands in Europe ?

Frank Goenninger
 

Am 30.10.2006 um 12:02 schrieb R L Measures:

Hello, Frank == A HV fuse in the secondary does not protect the HV-
transformer any better than a circuit breaker in the primary. cheerz
Yes, but it might protect a few other parts of the PS...

Thanks, Rich, for the heads up.

73, Frank DG1SBG


Re: Kit Amp

 

craxd wrote:

Larry,

This bound to have been in the early 70's or so. I had a GTE/Philco
19" TV I took in as a trade in and I played it myself for about a
year before I sold it. I can't remember if it was all solid state or
if it was a hybrid. Seems to me they had an old paper type light
green colored PC board in them. I think they was about the first to
own the Philco name after Ford, maybe bought it from them? North
American Phillips ended up with all three names. As far as I know,
N.A.P. no longer is selling new Philcos, only Magnavox and Sylvania.

Philco was the set for a private dealer to get a franchise on as
Sylvania and Magnavox was being pushed by the large chain stores. It
was all that was available over Lowes and a few other large stores
starting to sell them in the early 80's. Lowes was who hurt me. Now,
I don't think Lowes even handles TV sets. RCA was bad to not protect
a teritory and set someone else up a mile away so I never looked at
them. I had the Quasar sales for a while also, but they got just too
hard to work with. Now they're all chain store items.

Best,

Will

--- In ham_amplifiers@... <mailto:ham_amplifiers%40yahoogroups.com>, Larry Anderson
<larryw6lar@...> wrote:

craxd wrote:

Bill,

That is exactly the truth. When I started in repair (radio and
TV),
tube sets were still around. There, you replaced parts in a
chassis
with point to point wiring. Next came addition of PC boards with
tubes, and then the hybrid sets came having both tubes and solid
state devices. After that came the modules. That was easy fixes,
however the power supplies power components like resistors, etc
were
still mounted on tie strips, etc. Zenith modular sets were my
favorite with the upright chassis. Magnavox had one similar.
Motorola, soon to be Quasar had the "works in a drawer". Next came
the replacable chassis. No more modules, they wanted you to change
the whole chassis out. Then it was only one large flimsy PC
board. I
repaired most of these anyhow and only changed a chassis after
lightning damage. First you had a chassis and a tuner. Finally,
the
one board included both. I forgot to mention that hot chassis
started
about this time or a little earlier. I was selling and servicing
Philco TV's at the time for North American Phillips. Phillips
bought
Philco from GTE. Then, all Phillips did was run the same TV set
down
the line and put 1 of 3 name tags on them, Philco, Magnavox, or
Sylvania. About this time is when the mass marketing of TV's
began by
Lowes, K-Mart, and others large chain stores. They could sell a
set
at the same price as what a private dealer could buy one for. That
closed a lot of repair shops including mine. Eventually, sets got
so
cheap that you could throw them away as the cost of repair was at
least 50-76% of a new set. This especially true for 19 inch TV's
on
down. VCR's did the same thing too. Now you can buy a new VCR for
about $50.

All that's taught for service anymore is replacing a chassis, and
most of it is building PC's. Vacuum tube technology is not taught
anywhere I know of. After some of us older folks are gone, I
wonder
who will actually be able to do real repair work anymore?

Best,

Will

--- In ham_amplifiers@...
<mailto:ham_amplifiers%40yahoogroups.com>
<mailto:ham_amplifiers%40yahoogroups.com>, Bill Turner <dezrat@>
wrote:

We seem to be casting a lot of blame on individuals, but I
believe
the
underlying problem isn't people, it is the nature of electronic
equipment these days.

A lot of us got our start by being repairmen, and to do that
kind of
work well, one must understand the fundamentals of electronics.
These
days, you either change a PC board (if it is an expensive piece
of
gear), or you just throw it out and buy another. So-called
"technicians" anymore are mostly just parts changers, not real
repairmen. I don't see that changing any time in the near
future.

Of course there are some real technicians around, but any more
they
are working mostly at the engineering level, not the field
repair
level, and there are not a lot of them because not a lot are
needed.
Once the bugs are worked out of a design, you just make 'em by
the
millions and toss the bad ones.

Sad but true.

Bill, W6WRT
Will,
Question? When did GTE own Philco? I've been with them (GTE/
Verizon) for
43 years and I only know that they owned Sylvania.Was that before
my
time there. Just wondering.

Larry, W6LAR
Will,
I think you jogged my memory as after I ask the question I seemed to remember that just before GTE sold out the Sylvania line they did take on Philco from Ford. Boy! thats a long time ago. We used to have an "Employee Store" at selected company yards integrated with our supply department and all of the Sylvania products were offered and you could purchase on "time" payment through payroll deduction with no interest. Was a great deal for those of us just starting out to get some nice electronics. I still have a few items I purchased there. Thanks for the info Will.

Larry, W6LAR


Re: HV Fuses: Manufactures/brands in Europe ?

Frank Goenninger
 

Hi again:

Further digging into details of the SIBA web site revealed a search
function:



Specifying a voltage of 6 kV gives a result for a 8 x 120 mm fuse
having a rated current of up to 4 A. I am going to try to use one of
these...

73 de Frank DG1SBG


Am 30.10.2006 um 10:08 schrieb Frank Goenninger:

Hi all:

I am about to finish my HV power supply. One thing missing still is
an appropriate HV fuse to be put between C bank and glitch R. While
closely examining the pictures in the photos section of this group I
couldn't find any European manufacturer or distributor of HV fuses.

I found SIBA () - but they do provide fuses for
even "bigger" applications... I'd need something suitable for the 3,5
kV / 3 A coming out of my 300 ?F C bank...

Any suggestions? Thx for feedback!

73 Frank DG1SBG


Re: HV Fuses: Manufactures/brands in Europe ?

 

On Oct 30, 2006, at 1:08 AM, Frank Goenninger wrote:

Hi all:

I am about to finish my HV power supply. One thing missing still is
an appropriate HV fuse to be put between C bank and glitch R. While
closely examining the pictures in the photos section of this group I
couldn't find any European manufacturer or distributor of HV fuses.

I found SIBA () - but they do provide fuses for
even "bigger" applications... I'd need something suitable for the 3,5
kV / 3 A coming out of my 300 ?F C bank...

Any suggestions? Thx for feedback!
Hello, Frank == A HV fuse in the secondary does not protect the HV-
transformer any better than a circuit breaker in the primary. cheerz

73 Frank DG1SBG
...
R L Measures, AG6K, 805.386.3734
r@..., , rlm@..., www.somis.org


HV Fuses: Manufactures/brands in Europe ?

Frank Goenninger
 

Hi all:

I am about to finish my HV power supply. One thing missing still is
an appropriate HV fuse to be put between C bank and glitch R. While
closely examining the pictures in the photos section of this group I
couldn't find any European manufacturer or distributor of HV fuses.

I found SIBA () - but they do provide fuses for
even "bigger" applications... I'd need something suitable for the 3,5
kV / 3 A coming out of my 300 ?F C bank...

Any suggestions? Thx for feedback!

73 Frank DG1SBG


Re: Kit Amp

craxd
 

Larry,


This bound to have been in the early 70's or so. I had a GTE/Philco
19" TV I took in as a trade in and I played it myself for about a
year before I sold it. I can't remember if it was all solid state or
if it was a hybrid. Seems to me they had an old paper type light
green colored PC board in them. I think they was about the first to
own the Philco name after Ford, maybe bought it from them? North
American Phillips ended up with all three names. As far as I know,
N.A.P. no longer is selling new Philcos, only Magnavox and Sylvania.

Philco was the set for a private dealer to get a franchise on as
Sylvania and Magnavox was being pushed by the large chain stores. It
was all that was available over Lowes and a few other large stores
starting to sell them in the early 80's. Lowes was who hurt me. Now,
I don't think Lowes even handles TV sets. RCA was bad to not protect
a teritory and set someone else up a mile away so I never looked at
them. I had the Quasar sales for a while also, but they got just too
hard to work with. Now they're all chain store items.

Best,

Will


--- In ham_amplifiers@..., Larry Anderson
<larryw6lar@...> wrote:

craxd wrote:

Bill,

That is exactly the truth. When I started in repair (radio and
TV),
tube sets were still around. There, you replaced parts in a
chassis
with point to point wiring. Next came addition of PC boards with
tubes, and then the hybrid sets came having both tubes and solid
state devices. After that came the modules. That was easy fixes,
however the power supplies power components like resistors, etc
were
still mounted on tie strips, etc. Zenith modular sets were my
favorite with the upright chassis. Magnavox had one similar.
Motorola, soon to be Quasar had the "works in a drawer". Next came
the replacable chassis. No more modules, they wanted you to change
the whole chassis out. Then it was only one large flimsy PC
board. I
repaired most of these anyhow and only changed a chassis after
lightning damage. First you had a chassis and a tuner. Finally,
the
one board included both. I forgot to mention that hot chassis
started
about this time or a little earlier. I was selling and servicing
Philco TV's at the time for North American Phillips. Phillips
bought
Philco from GTE. Then, all Phillips did was run the same TV set
down
the line and put 1 of 3 name tags on them, Philco, Magnavox, or
Sylvania. About this time is when the mass marketing of TV's
began by
Lowes, K-Mart, and others large chain stores. They could sell a
set
at the same price as what a private dealer could buy one for. That
closed a lot of repair shops including mine. Eventually, sets got
so
cheap that you could throw them away as the cost of repair was at
least 50-76% of a new set. This especially true for 19 inch TV's
on
down. VCR's did the same thing too. Now you can buy a new VCR for
about $50.

All that's taught for service anymore is replacing a chassis, and
most of it is building PC's. Vacuum tube technology is not taught
anywhere I know of. After some of us older folks are gone, I
wonder
who will actually be able to do real repair work anymore?

Best,

Will

--- In ham_amplifiers@...
<mailto:ham_amplifiers%40yahoogroups.com>, Bill Turner <dezrat@>
wrote:

We seem to be casting a lot of blame on individuals, but I
believe
the
underlying problem isn't people, it is the nature of electronic
equipment these days.

A lot of us got our start by being repairmen, and to do that
kind of
work well, one must understand the fundamentals of electronics.
These
days, you either change a PC board (if it is an expensive piece
of
gear), or you just throw it out and buy another. So-called
"technicians" anymore are mostly just parts changers, not real
repairmen. I don't see that changing any time in the near
future.

Of course there are some real technicians around, but any more
they
are working mostly at the engineering level, not the field
repair
level, and there are not a lot of them because not a lot are
needed.
Once the bugs are worked out of a design, you just make 'em by
the
millions and toss the bad ones.

Sad but true.

Bill, W6WRT
Will,
Question? When did GTE own Philco? I've been with them (GTE/
Verizon) for
43 years and I only know that they owned Sylvania.Was that before
my
time there. Just wondering.

Larry, W6LAR