Re: Kit Amp
By R L Measures · #768 ·
Re: Kit Amp
amazed at some of the elemental questions asked by persons with extra class call signs. > Rich Sez... I have found that few Extras know Ohm's Law. should be plastered on page 1 of all these books. ###
By pentalab <jim.thomson@...> · #767 ·
Re: Kit Amp
I have found that few Extras know Ohm's Law. ... R L Measures, AG6K, 805.386.3734 r@..., , rlm@..., www.somis.org
By R L Measures · #766 ·
BIG tubes on this weekend !!
Cq ww ssb contest this weekend. You will be hearing some BIG tubes this weekend... all bands. Good... cuz I helped design several of em. Hope they have fun.... more power to em ....[no pun intended,
By pentalab <jim.thomson@...> · #765 ·
Re: Kit Amp
I belong to several of these ham discussion groups and also am amazed at some of the elemental questions asked by persons with extra class call signs. I am not an electronics engineer or anything like
By david6fl <dhallam@...> · #764 ·
Re: Kit Amp
There are a couple over here in Europe. So does that mean European hams are brighter! :-) Linear Amp UK sell their Ranger 811 HF amp as a kit and also make available parts like transformers,
By Paul · #763 ·
Re: Kit Amp
There are a couple over here in Europe. So does that mean European hams are brighter! :-) Linear Amp UK sell their 4 x 811 amp as a kit And in Denmark Dan's amps
By Paul · #762 ·
Re: Kit Amp
Bill, how sad, but true. I am amazed at the number of new licensees in the local club, some Extra Class, who don't have the foggiest idea how to calculate the length of a dipole, or how to put it up.
By Mike&#92;(W5UC&#92;) & Kathy&#92;(K5MWH&#92;) <w5uc@...> · #761 ·
Re: w5uc's pi net spread sheet...deluxe.
Good Morning Gary & All: Thanks for the comments. Nope, never have worked for Lufkin Industries. However, your comments started me thinking about the amplifier projects I have done in my life as a
By Mike&#92;(W5UC&#92;) & Kathy&#92;(K5MWH&#92;) <w5uc@...> · #759 ·
Re: Kit Amp
ORIGINAL MESSAGE: wrote: ------------ REPLY FOLLOWS ------------ Perhaps it could be done with blank metal pieces and a paper template for the builder to drill and finish himself? Your other comments
By Bill Turner <dezrat@...> · #760 ·
Re: Grounding Grids on 3-500Z's
? What failure does the HV fuse protect against with thoriated tungsten filament tubes?
By R L Measures · #758 ·
Re: w5uc's pi net spread sheet...deluxe.
Nice pix of the 6 mtr project. Looks like you have done layout work before. Living in Lufkin, TX, do you work for the measuring device outfit? Have an old Lufkin 50 ft. tape measure that must be 60-70
By Gary Smith · #757 ·
Re: w5uc's pi net spread sheet...deluxe.
pentalab wrote:
By Tony King - W4ZT <w4zt-060920@...> · #756 ·
Re: chimney material
pentalab wrote: <snip> There's nothing better! > <snip> Jim, have you considered sub mounting the tube? Current methods dictate cutting lots of holes around the tube to allow the air to flow. If you
By Tony King - W4ZT <w4zt-060920@...> · #755 ·
Re: Grounding Grids on 3-500Z's
repairing 500 pf prevent grid- filament shorts. ### agreed... when stuff "goes nuts"... the glitch will LIMIT current..... precede the glitch with a HV fuse... and that combo is excellent. Come glitch
By pentalab <jim.thomson@...> · #754 ·
Re: w5uc's pi net spread sheet...deluxe.
Kathy&#92;(K5MWH&#92;)" <w5uc@...> wrote: 6 mtrs see my #### then click on..."stuff" I tried the pi net for my tuned inputs.... and it's slick.... since it does ALL bands at once. By tweaking the Q in
By pentalab <jim.thomson@...> · #753 ·
Re: chimney material
### Have not tried this... yet. You would have to anchor it down to the chassis... otherwise, it would obviously get blown through the celing ! Since our local plastic shop has miles of thin teflon
By pentalab <jim.thomson@...> · #752 ·
Re: Grounding Grids on 3-500Z's
In my experiences, a suitable glitch-R in the HV+ helps prevent grid- filament shorts.
By R L Measures · #751 ·
Re: TL922 transformer and other
Will, I agree. When you design a transformer for 10 KG there is an oversized core or extra windings both of wich increase the resistance losses. This same transformer at 50 Hz. will be more efficient
By FRANCIS CARCIA <carcia@...> · #750 ·
Re: [??????????????] Re: TL922 transformer and otherr
Materials like kapton insulators are rated at 7000 volts / mil do a better job than a layer of paint. This is required when you build high voltage transformers. Low voltage you can rely on wire
By FRANCIS CARCIA <carcia@...> · #749 ·