¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Electrolytic Caps.
Derated for 105C = 600 X .91 = 546V Voltage derating (0.91VR) enables 105¡ãC operation BUT only 85C rated, that could be rough when using a high ripple doubler HV PS.
By Roy Talbert · #37151 ·
Re: Electrolytic Caps.
BUT only 85C rated, that could be rough when using a high ripple doubler HV PS.
By Carl · #37150 ·
Re: Tokyo Hy Power HL-45B question.
Assuming that the amp is functional, are you sure you that you don¡¯t have it in standby or that it is being keyed properly by the radio. You don¡¯t need ALC when then amp is driven with almost any
By Omni · #37149 ·
Electrolytic Caps.
For those who might be building or considering a HV power supply, Newark currently has a promotional price on 600V 270uF caps that appears to be a bargain.
By Roy Talbert · #37148 ·
Tokyo Hy Power HL-45B question.
I recently acquired a Tokyo Hypower HL-45B in excellent cosmetic condition. I do not have a Yaesu FT817 and attempted to drive the amp with another qrp rig @ 5 watts with no alc cable between the amp
By Terry ONeill · #37147 ·
Re: Fl2100z feedback
Yeah! It's the first 6dB that makes all the difference. 73, Alek. VK6APK
By Alek Petkovic · #37146 ·
Fl2100z feedback
Linear fine and running directly off the orion 2 as was suggested.? Dx pouring in.? Seriously.? Even at500 watts Very happy. -- David G4YVM
By David Perry <bumbledp@...> · #37145 ·
Re: fl2100Z misery...
Fault lies in the rf hot line.? When the operate relay is switched to operate the rf line goes open circuit
By David Perry <bumbledp@...> · #37144 ·
fl2100Z misery...
Oh woe is me. I have been using the linear with my Tentec Orion quite happily, manually switching the relay not via the rig nor leaving it permanently shorted as when I found it. ?I have been running
By David Perry <bumbledp@...> · #37143 ·
Re: fl2100z / Tentec Orion 2
Yes. That is a great solution. I have a 5kVA unit with 10V taps from -40V to +20V compared to the incoming mains. I use it on my AL-1500 and HF-2500 amps. I run them on 230V and they are very happy
By Alek Petkovic · #37142 ·
Re: fl2100z / Tentec Orion 2
autotransformer is the solution.
By W2XJ <w2xj@...> · #37141 ·
Re: fl2100z / Tentec Orion 2
By W7WRX · #37140 ·
Re: fl2100z / Tentec Orion 2
The biggest single issue in this country (Australia) with the 2100 amps and a lot of others, for that matter, is the filament voltage. Due to our 240V to 250V mains, it is always high. With the 2100
By Alek Petkovic · #37139 ·
Re: fl2100z / Tentec Orion 2
Make sure the Orion cam tolerate the keyline voltage of the fl2100z. Not sure, but you may need a buffer to protect the radio. 73, N0NC Chuck
By Chuck Miller · #37138 ·
Re: fl2100z / Tentec Orion 2
I have a 2100B to use with the FT 101 station.? I take it to the cabin and use it on all bands. Typically run it at 500 out. Never had a single issue with it ever. Its possible it was worked on at
By W7WRX · #37137 ·
Re: fl2100z / Tentec Orion 2
I? had a brand? new? FL-2100B? back? in 1976.? ?Worked? on? all? bands...? for a while. Then? on? 10M,? it? flat? out? would? not? tune? properly on? 10M..into a flat? swr. The?
By Jim VE7RF · #37136 ·
Re: fl2100z / Tentec Orion 2
FL2100B (not Z, but quite similar) with FT-450, at the club Regards Guillermo - LU5WE.
By GG LL <guiye8@...> · #37135 ·
Re: fl2100z / Tentec Orion 2
Anyone using a fl200z with anything...?
By David Perry <bumbledp@...> · #37134 ·
fl2100z / Tentec Orion 2
Ive been very kindly loaned a 2100Z to try with my Orion 2. Anything I should be aware of before I hit the "smoke on" button? David G4YVM
By David Perry <bumbledp@...> · #37133 ·
Re: Question about Ameritron AL-1200 Amp (Uses one 3CX1200Z7 tube)
Cliff,? the? link? for? the? ameritron? site? does? not? work? for? the AL1200? manual? (nor? the? AL-1500,? under? downloads). The 2nd? link? works....? but? not sharp,?
By Jim VE7RF · #37132 ·