Re: Equipment Interconnect cables

 

开云体育

The problem with RG-142 is that the solid center conductor is easy to displace when the coax is bent, especially sharp bends, and particularly short lengths such as less than several feet. It's best not to bend -142 short jumpers more than necessary. You can tell when the center conductor is displaced by examining the center pins in the end: it'll be offset on one end compared to the other. (This is especially obvious when BNC or SMA, the most common connectors used with -142, are used.) Otherwise, -142 is a good coax and readily withstands high power.

Steve, K0XP


On 11/11/2024 10:44 AM, Dave w6de wrote:

Correction to my previous post.? I do not use RG-400 jumpers, I use RG-142 coax jumpers.

Both RG-400 and RG-142 have similar specs with the exception of RG-142 has a solid center conductor and RG-400 has a stranded center conductor.? I find the flexibility of the center conductor RG-142 to be suitable for short connections in the shack.? If I were to make a tightly wound choke RG-400 would be the appropriate choice.

?

73,

Dave, w6de

?

?

From: [email protected] <[email protected]> On Behalf Of Dave w6de via groups.io
Sent: 11 November, 2024 18:09
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack.

?

73,

Dave, w6de

?

From: [email protected] <[email protected]> On Behalf Of Bob via groups.io
Sent: 11 November, 2024 12:32
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

Yes that RG-400 is great and can make sharp bends if need be.

Bob W4JFA

?

On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:

I use rg400 coax. Same size as rg58, but teflon insulated and ok for 3kw, or even more on ssb. Not cheap... Thanks des.?

--
See my QRZ.com page at


Re: Equipment Interconnect cables

 

Holy crap those jumper are over $100 each. Too rich for me. I will stick with RG8X and my stock of PL-259s. This has worked for me many years now. I realize that it should not be used for 1500 watts that has any VSWR on it. My VSWR on my two antennas range from 1.2 to 1.6 on a trapped 75 meter dipole. Those connections are all done with something that looks like RG8 but has some other number on it.?
?
I would need jumpers for my VSWR meter and amplifier. I think that comes to 4 jumpers. That would be over $400 dollars from DX Engineering. I know that I am not the only one using RG8X for 1500 watts. My closest neighbor ham is using it.?
?
I also have an antenna switch that may have up to a 1.6 to 1 VSWR on it. It is wired with this RG8 looking stuff. I also use the PL-259 quick disconnects adapters. This makes it easy to pull the antenna connections when a storm is coming.?
?
I would seriously like to hear if there is a reason why I should not use RG8X the way I am using it. I am always open to ideas and opinions. I fully realize that my own understanding of RF is quite limited. I have worked in design of devices that did not carry RF and were low power low frequency stuff limited to 4 mhz.?


Re: Equipment Interconnect cables

 

开云体育

Correction to my previous post.? I do not use RG-400 jumpers, I use RG-142 coax jumpers.

Both RG-400 and RG-142 have similar specs with the exception of RG-142 has a solid center conductor and RG-400 has a stranded center conductor.? I find the flexibility of the center conductor RG-142 to be suitable for short connections in the shack.? If I were to make a tightly wound choke RG-400 would be the appropriate choice.

?

73,

Dave, w6de

?

?

From: [email protected] <[email protected]> On Behalf Of Dave w6de via groups.io
Sent: 11 November, 2024 18:09
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack.

?

73,

Dave, w6de

?

From: [email protected] <[email protected]> On Behalf Of Bob via groups.io
Sent: 11 November, 2024 12:32
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

Yes that RG-400 is great and can make sharp bends if need be.

Bob W4JFA

?

On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:

I use rg400 coax. Same size as rg58, but teflon insulated and ok for 3kw, or even more on ssb. Not cheap... Thanks des.?


Re: Equipment Interconnect cables

 

开云体育

Lots of premade RG-400 cables are at DXE – like this:

?

Search for RG-400

?

73

Tim K3LR @ DXE HQ

?

From: [email protected] [mailto:[email protected]] On Behalf Of Dave w6de
Sent: Monday, November 11, 2024 1:09 PM
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack.

?

73,

Dave, w6de

?

From: [email protected] <[email protected]> On Behalf Of Bob via groups.io
Sent: 11 November, 2024 12:32
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

Yes that RG-400 is great and can make sharp bends if need be.

Bob W4JFA

?

On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:

I use rg400 coax. Same size as rg58, but teflon insulated and ok for 3kw, or even more on ssb. Not cheap... Thanks des.?


Re: Equipment Interconnect cables

 

开云体育

I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack.

?

73,

Dave, w6de

?

From: [email protected] <[email protected]> On Behalf Of Bob via groups.io
Sent: 11 November, 2024 12:32
To: [email protected]
Subject: Re: [ham-amplifiers] Equipment Interconnect cables

?

Yes that RG-400 is great and can make sharp bends if need be.

Bob W4JFA

?

On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:

I use rg400 coax. Same size as rg58, but teflon insulated and ok for 3kw, or even more on ssb. Not cheap... Thanks des.?


Re: Equipment Interconnect cables

 

Yes that RG-400 is great and can make sharp bends if need be.
Bob W4JFA

On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:
I use rg400 coax. Same size as rg58, but teflon insulated and ok for 3kw, or even more on ssb. Not cheap... Thanks des.?


Re: Equipment Interconnect cables

 

I use rg400 coax. Same size as rg58, but teflon insulated and ok for 3kw, or even more on ssb. Not cheap... Thanks des.?


Re: the WORST ham built amplifier?

 

I only ever heard Seymour on 20m.? He was a real character.? ?He was stupid loud here, with his yagi pointed my way.

Those mile long leads will screw up the coil values a bunch.... on those depicted tuned inputs.
?
56% eff isn't good at all.? ?You shoulda been able to get 68% eff on? 160-40m.? ?I'm assuming? your plate current meter, HV meter, wattmeter are all? calibrated ??


Re: Equipment Interconnect cables

 

RG8X might become limp with 1.5 kw CXR /? data modes, FT-8 / FM.?


Re: Dentron Clipperton L

 

I found this.
Bob W4JFA?

On Sat, Nov 9, 2024, 4:25 PM Billy Pickering via <pickeringw=[email protected]> wrote:
Hello, I currently have a Dentron clipperton L that I have been tinkering with and I know that some of the last models had a tuned input that came with the amp. I’m looking for a manual/schematic for this as I’m wanting to build one to put in the amp. I have a CM-1 but just trying to eliminate some cabling. Here are some pictures of the cleanup/restoration.


Re: Equipment Interconnect cables

 

I have used RG8X for years without a problem. They are all short and losses immeasurable. The cables out to my antennas from the shack are all RG8 or something like that. Mine have handled 1500 watts just fine. It might not be fine if they were not all into 50 ohm loads. I have an RG8X jumper to my tuner and that is tuned at low power. When 1500 watts hits this RG8X it has a 50 ohm match. I have a neighbor who does the same thing as myself with interconnects with his amplifier, transceiver, VSWR meter, and tuner.?


Equipment Interconnect cables

 

Hello,
?
In HF service, when running interconnect coax cables from an amplifier outbound, I have always used RG-213 or equivalent from the amp to whatever accessories I was using at the time such as a monitor scope, power meter, ATU, etc. then on to the antenna. Since the interconnect cabling are usually very short lengths, is it acceptable today to use RG-8X for this when running high power or is it standard practice to use the heavier coax?
?
73,
Garry


Dentron Clipperton L

 

Hello, I currently have a Dentron clipperton L that I have been tinkering with and I know that some of the last models had a tuned input that came with the amp. I’m looking for a manual/schematic for this as I’m wanting to build one to put in the amp. I have a CM-1 but just trying to eliminate some cabling. Here are some pictures of the cleanup/restoration.


Re: TenTec Centurion HV arc to ground

 

开云体育

If you have any teflon sleeving, put an inch length over the wire where it goes through the grommet. If you only have teflon sheet, cut an inch square and wrap it around the wire through the grommet. If you don't have any teflon, use plastic bag but I'd be wary of plastic. I've never used it in this manner but some plastics break down really easily in the presence of high voltage. 0.01"-thick teflon withstands 1900 VDC, so a double or triple-wrap of sheet would easily work. I've used 0.019" teflon sheet to build HV bypass capacitors for the old AM-6154/6155 amplifiers before.

Steve, K0XP


On 11/9/2024 9:26 AM, Robin Midgett via groups.io wrote:
Thanks Jim, I agree with your assessment. I replaced the feed through with a rubber grommet?and soldered the HV wire directly to the glitch resistor. That seems to work fine business.



Thanks,
Robin Midgett K4IDC


On Fri, Nov 8, 2024 at 9:12?AM Jim VE7RF via <jim.thom=[email protected]> wrote:
That's caused by....'surface creep'..... which will also depend on any dust/gunk / fluff sitting on the insulator.? ?The insulator can be cleaned up. The easy fix is to put a small piece of plastic sheet (with a hole in it). ..before the arced insulator is installed.? That will increase the leakage path by a bunch. ( plastic goes between the insulator and metal side wall)...so the hole in the plastic is just big enough....then the lip of the insulator sits on the plastic sheeting.? ? ?That or replace with a longer feedthrough HV connector, or use a feedthrough insulator ( 2 x piece type)...that is of the serrated type....which will also increase the leakage path by a bunch.?
--
See my QRZ.com page at


Re: TenTec Centurion HV arc to ground

 

Thanks for the kind offer, Tom. A trusted friend and amp builder suggested?a simpler fix..toss the feed through & replace it with a rubber grommet, solder the wire directly to the glitch resistor. That's what I did & it seems to be a good solution so far.



Thanks,
Robin Midgett K4IDC


On Fri, Nov 8, 2024 at 7:31?AM Tom Hellem via <tom.hellem=[email protected]> wrote:
Robin-
I may have a longer ceramic insulator that would fit your needs.
Tell me how long it should be and I will check the junk box.

Tom
K0SN?

On Thu, Nov 7, 2024 at 6:58?PM Robin Midgett via <RobinK4IDC=[email protected]> wrote:
Yes, these are the notions I've had about the remedy; maybe make an insulator from a solid rod of fiberglass or Teflon with a recess in one end to surround the bolt/nut/solder lug.
Thanks Eric!


Thanks,
Robin Midgett K4IDC


On Thu, Nov 7, 2024 at 7:51?PM Eric via <vzwengr=[email protected]> wrote:
I can't tell if the break-down happened because of a defect in the insulator, or if corona from a sharp edge degraded the insulator.? Either way, the insulator should be replaced as it will be impossible to get rid of the carbon track on the insulator.?

There is quite a lot of bolt sticking out of the top of the insulator.? If one can be found, a taller insulator, using the same length bolt, would be a good idea.

Eric
WB6TIX

On Thu, Nov 7, 2024 at 6:10?PM Robin Midgett via <RobinK4IDC=[email protected]> wrote:

I'd like to know if any of?you have suggestions as to what caused this HV arc to chassis and hopefully, what to do to prevent it in the?future.
Amp is a TenTec Centurion. It was at idle when the arc happened; no RF applied. The glitch resistor took the brunt of the discharge, thank goodness. I've replaced it,?even though the original still?measured the?correct?resistance, it was visually damaged. The event spooked me...new pair of 3-500Z tubes was in the amp; no apparent?damage.
The insulator appears to be made of fiberglass. The glitch resistor is on the opposite side of this aluminum panel. The HV feeds through from the resistor via the machine screw. Any thoughts?

IMG_20241107_184817794.jpg


Thanks,
Robin Midgett K4IDC


Re: TenTec Centurion HV arc to ground

 

Thanks Jim, I agree with your assessment. I replaced the feed through with a rubber grommet?and soldered the HV wire directly to the glitch resistor. That seems to work fine business.



Thanks,
Robin Midgett K4IDC


On Fri, Nov 8, 2024 at 9:12?AM Jim VE7RF via <jim.thom=[email protected]> wrote:
That's caused by....'surface creep'..... which will also depend on any dust/gunk / fluff sitting on the insulator.? ?The insulator can be cleaned up. The easy fix is to put a small piece of plastic sheet (with a hole in it). ..before the arced insulator is installed.? That will increase the leakage path by a bunch. ( plastic goes between the insulator and metal side wall)...so the hole in the plastic is just big enough....then the lip of the insulator sits on the plastic sheeting.? ? ?That or replace with a longer feedthrough HV connector, or use a feedthrough insulator ( 2 x piece type)...that is of the serrated type....which will also increase the leakage path by a bunch.?


Re: My 2K-4

 

开云体育

In Kentucky, the Electrical Code (as applied)

specifies the last (or first) cabinet or bay

wherein the Neutral and Ground both appear

prior to the entranceway or distribution panel,

be bonded.

?

While I was in New Jersey my quarters were

rented, and I had no desire to explore any

of the building infrastructure, but I imagine

the code requirements were NFPA, etc.,

and the fault was in the refrigerator

compressor capacitors leaking to the

metal frame, the refrigerator vintage only

seeing a two-prong a.c. connection.

?

Hal Mandel

W4HBM


Re: My 2K-4

 

开云体育

“From that point out, the NEUTRAL and the GROUND conductors, are always separate conductors. They are NEVER (or shouldn't be) tied together anywhere else in the system”.
I think I said that…..thanks, Alan.
John VK6JX

On 5 Nov 2024, at 1:44?AM, Alan - W5ARM via groups.io <W5ARM.mail@...> wrote:

From that point out, the NEUTRAL and the GROUND conductors, are always separate conductors. They are NEVER (or shouldn't be) tied together anywhere else in the system.


Re: TenTec Centurion HV arc to ground

 

That's caused by....'surface creep'..... which will also depend on any dust/gunk / fluff sitting on the insulator.? ?The insulator can be cleaned up. The easy fix is to put a small piece of plastic sheet (with a hole in it). ..before the arced insulator is installed.? That will increase the leakage path by a bunch. ( plastic goes between the insulator and metal side wall)...so the hole in the plastic is just big enough....then the lip of the insulator sits on the plastic sheeting.? ? ?That or replace with a longer feedthrough HV connector, or use a feedthrough insulator ( 2 x piece type)...that is of the serrated type....which will also increase the leakage path by a bunch.?


Re: TenTec Centurion HV arc to ground

 

That pointy end of the wire probably doesn't help. The ceramic feedthru from a Heathkit SB220 would probably work. Never seen one arc.

On Friday, November 8, 2024 at 08:45:10 AM EST, Bob <w4jfabob@...> wrote:


This reminds me of my automotive days. Anything, I mean anything not right with the ceramic insulator on a spark plug will cause a misfire. Same thing is possible here.
Bob W4JFA

On Fri, Nov 8, 2024 at 8:31?AM Tom Hellem via <tom.hellem=[email protected]> wrote:
Robin-
I may have a longer ceramic insulator that would fit your needs.
Tell me how long it should be and I will check the junk box.

Tom
K0SN?

On Thu, Nov 7, 2024 at 6:58?PM Robin Midgett via <RobinK4IDC=[email protected]> wrote:
Yes, these are the notions I've had about the remedy; maybe make an insulator from a solid rod of fiberglass or Teflon with a recess in one end to surround the bolt/nut/solder lug.
Thanks Eric!


Thanks,
Robin Midgett K4IDC


On Thu, Nov 7, 2024 at 7:51?PM Eric via <vzwengr=[email protected]> wrote:
I can't tell if the break-down happened because of a defect in the insulator, or if corona from a sharp edge degraded the insulator.? Either way, the insulator should be replaced as it will be impossible to get rid of the carbon track on the insulator.?

There is quite a lot of bolt sticking out of the top of the insulator.? If one can be found, a taller insulator, using the same length bolt, would be a good idea.

Eric
WB6TIX

On Thu, Nov 7, 2024 at 6:10?PM Robin Midgett via <RobinK4IDC=[email protected]> wrote:

I'd like to know if any of?you have suggestions as to what caused this HV arc to chassis and hopefully, what to do to prevent it in the?future.
Amp is a TenTec Centurion. It was at idle when the arc happened; no RF applied. The glitch resistor took the brunt of the discharge, thank goodness. I've replaced it,?even though the original still?measured the?correct?resistance, it was visually damaged. The event spooked me...new pair of 3-500Z tubes was in the amp; no apparent?damage.
The insulator appears to be made of fiberglass. The glitch resistor is on the opposite side of this aluminum panel. The HV feeds through from the resistor via the machine screw. Any thoughts?

IMG_20241107_184817794.jpg


Thanks,
Robin Midgett K4IDC