Keyboard Shortcuts
Likes
- Ham-Amplifiers
- Messages
Search
Re: Equipment Interconnect cables
开云体育The problem with RG-142 is that the solid center conductor is easy to displace when the coax is bent, especially sharp bends, and particularly short lengths such as less than several feet. It's best not to bend -142 short jumpers more than necessary. You can tell when the center conductor is displaced by examining the center pins in the end: it'll be offset on one end compared to the other. (This is especially obvious when BNC or SMA, the most common connectors used with -142, are used.) Otherwise, -142 is a good coax and readily withstands high power. Steve, K0XP
On 11/11/2024 10:44 AM, Dave w6de
wrote:
--
See my QRZ.com page at |
Re: Equipment Interconnect cables
Holy crap those jumper are over $100 each. Too rich for me. I will stick with RG8X and my stock of PL-259s. This has worked for me many years now. I realize that it should not be used for 1500 watts that has any VSWR on it. My VSWR on my two antennas range from 1.2 to 1.6 on a trapped 75 meter dipole. Those connections are all done with something that looks like RG8 but has some other number on it.?
?
I would need jumpers for my VSWR meter and amplifier. I think that comes to 4 jumpers. That would be over $400 dollars from DX Engineering. I know that I am not the only one using RG8X for 1500 watts. My closest neighbor ham is using it.?
?
I also have an antenna switch that may have up to a 1.6 to 1 VSWR on it. It is wired with this RG8 looking stuff. I also use the PL-259 quick disconnects adapters. This makes it easy to pull the antenna connections when a storm is coming.?
?
I would seriously like to hear if there is a reason why I should not use RG8X the way I am using it. I am always open to ideas and opinions. I fully realize that my own understanding of RF is quite limited. I have worked in design of devices that did not carry RF and were low power low frequency stuff limited to 4 mhz.? |
Re: Equipment Interconnect cables
开云体育Correction to my previous post.? I do not use RG-400 jumpers, I use RG-142 coax jumpers. Both RG-400 and RG-142 have similar specs with the exception of RG-142 has a solid center conductor and RG-400 has a stranded center conductor.? I find the flexibility of the center conductor RG-142 to be suitable for short connections in the shack.? If I were to make a tightly wound choke RG-400 would be the appropriate choice. ? 73, Dave, w6de ? ? From: [email protected] <[email protected]>
On Behalf Of Dave w6de via groups.io
Sent: 11 November, 2024 18:09 To: [email protected] Subject: Re: [ham-amplifiers] Equipment Interconnect cables ? I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack. ? 73, Dave, w6de ? From: [email protected] <[email protected]>
On Behalf Of Bob via groups.io ? Yes that RG-400 is great and can make sharp bends if need be. Bob W4JFA ? On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:
|
Re: Equipment Interconnect cables
开云体育Lots of premade RG-400 cables are at DXE – like this: ? Search for RG-400 ? 73 Tim K3LR @ DXE HQ ? From: [email protected] [mailto:[email protected]] On Behalf Of Dave w6de
Sent: Monday, November 11, 2024 1:09 PM To: [email protected] Subject: Re: [ham-amplifiers] Equipment Interconnect cables ? I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack. ? 73, Dave, w6de ? From: [email protected] <[email protected]> On Behalf Of Bob via groups.io ? Yes that RG-400 is great and can make sharp bends if need be. Bob W4JFA ? On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:
|
Re: Equipment Interconnect cables
开云体育I buy RG-400 jumpers for all my inside the shack interconnections.? Entering the shack, I have a mix of N connectors for Heliax LDF4 Superflex and PL-259 connectors for RG-213 coax for antenna connections/terminations from the outside antennas.? When I buy the RG-400 jumpers I specify the cable connectors for each end to keep from using adapters inside the shack. ? 73, Dave, w6de ? From: [email protected] <[email protected]>
On Behalf Of Bob via groups.io
Sent: 11 November, 2024 12:32 To: [email protected] Subject: Re: [ham-amplifiers] Equipment Interconnect cables ? Yes that RG-400 is great and can make sharp bends if need be. Bob W4JFA ? On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:
|
Re: Equipment Interconnect cables
Yes that RG-400 is great and can make sharp bends if need be. Bob W4JFA On Mon, Nov 11, 2024 at 1:58?AM desmond auld GI0UTE via <desauld=[email protected]> wrote:
|
Re: the WORST ham built amplifier?
I only ever heard Seymour on 20m.? He was a real character.? ?He was stupid loud here, with his yagi pointed my way.
Those mile long leads will screw up the coil values a bunch.... on those depicted tuned inputs. ?
56% eff isn't good at all.? ?You shoulda been able to get 68% eff on? 160-40m.? ?I'm assuming? your plate current meter, HV meter, wattmeter are all? calibrated ?? |
Re: Dentron Clipperton L
I found this. Bob W4JFA? On Sat, Nov 9, 2024, 4:25 PM Billy Pickering via <pickeringw=[email protected]> wrote:
|
Re: Equipment Interconnect cables
I have used RG8X for years without a problem. They are all short and losses immeasurable. The cables out to my antennas from the shack are all RG8 or something like that. Mine have handled 1500 watts just fine. It might not be fine if they were not all into 50 ohm loads. I have an RG8X jumper to my tuner and that is tuned at low power. When 1500 watts hits this RG8X it has a 50 ohm match. I have a neighbor who does the same thing as myself with interconnects with his amplifier, transceiver, VSWR meter, and tuner.? |
Equipment Interconnect cables
Hello,
?
In HF service, when running interconnect coax cables from an amplifier outbound, I have always used RG-213 or equivalent from the amp to whatever accessories I was using at the time such as a monitor scope, power meter, ATU, etc. then on to the antenna. Since the interconnect cabling are usually very short lengths, is it acceptable today to use RG-8X for this when running high power or is it standard practice to use the heavier coax?
?
73,
Garry |
Dentron Clipperton L
Hello, I currently have a Dentron clipperton L that I have been tinkering with and I know that some of the last models had a tuned input that came with the amp. I’m looking for a manual/schematic for this as I’m wanting to build one to put in the amp. I have a CM-1 but just trying to eliminate some cabling. Here are some pictures of the cleanup/restoration |
Re: TenTec Centurion HV arc to ground
开云体育If you have any teflon sleeving, put an inch length over the wire
where it goes through the grommet. If you only have teflon sheet,
cut an inch square and wrap it around the wire through the
grommet. If you don't have any teflon, use plastic bag but I'd be
wary of plastic. I've never used it in this manner but some
plastics break down really easily in the presence of high voltage.
0.01"-thick teflon withstands 1900 VDC, so a double or triple-wrap
of sheet would easily work. I've used 0.019" teflon sheet to build
HV bypass capacitors for the old AM-6154/6155 amplifiers before. Steve, K0XP
On 11/9/2024 9:26 AM, Robin Midgett via
groups.io wrote:
--
See my QRZ.com page at |
Re: TenTec Centurion HV arc to ground
Thanks for the kind offer, Tom. A trusted friend and amp builder suggested?a simpler fix..toss the feed through & replace it with a rubber grommet, solder the wire directly to the glitch resistor. That's what I did & it seems to be a good solution so far. Thanks, Robin Midgett K4IDC On Fri, Nov 8, 2024 at 7:31?AM Tom Hellem via <tom.hellem=[email protected]> wrote:
|
Re: TenTec Centurion HV arc to ground
Thanks Jim, I agree with your assessment. I replaced the feed through with a rubber grommet?and soldered the HV wire directly to the glitch resistor. That seems to work fine business. Thanks, Robin Midgett K4IDC On Fri, Nov 8, 2024 at 9:12?AM Jim VE7RF via <jim.thom=[email protected]> wrote:
|
Re: My 2K-4
开云体育In Kentucky, the Electrical Code (as applied) specifies the last (or first) cabinet or bay wherein the Neutral and Ground both appear prior to the entranceway or distribution panel, be bonded. ? While I was in New Jersey my quarters were rented, and I had no desire to explore any of the building infrastructure, but I imagine the code requirements were NFPA, etc., and the fault was in the refrigerator compressor capacitors leaking to the metal frame, the refrigerator vintage only seeing a two-prong a.c. connection. ? Hal Mandel W4HBM |
Re: My 2K-4
开云体育“From that point out, the NEUTRAL and the GROUND conductors, are always separate conductors. They are NEVER (or shouldn't be) tied together anywhere else in the system”. I think I said that…..thanks, Alan. John VK6JX On 5 Nov 2024, at 1:44?AM, Alan - W5ARM via groups.io <W5ARM.mail@...> wrote:
|
Re: TenTec Centurion HV arc to ground
That's caused by....'surface creep'..... which will also depend on any dust/gunk / fluff sitting on the insulator.? ?The insulator can be cleaned up. The easy fix is to put a small piece of plastic sheet (with a hole in it). ..before the arced insulator is installed.? That will increase the leakage path by a bunch. ( plastic goes between the insulator and metal side wall)...so the hole in the plastic is just big enough....then the lip of the insulator sits on the plastic sheeting.? ? ?That or replace with a longer feedthrough HV connector, or use a feedthrough insulator ( 2 x piece type)...that is of the serrated type....which will also increase the leakage path by a bunch.? |
Re: TenTec Centurion HV arc to ground
That pointy end of the wire probably doesn't help. The ceramic feedthru from a Heathkit SB220 would probably work. Never seen one arc.
On Friday, November 8, 2024 at 08:45:10 AM EST, Bob <w4jfabob@...> wrote:
This reminds me of my automotive days. Anything, I mean anything not right with the ceramic insulator on a spark plug will cause a misfire. Same thing is possible here. Bob W4JFA On Fri, Nov 8, 2024 at 8:31?AM Tom Hellem via <tom.hellem=[email protected]> wrote:
|