From the available data we have not seen Br depending temperature change from 25¡ã C to 100¡ã C.
Bordodynov.
05.08.2016, 15:56, "hkafeman@... [LTspice]" <ltspice@...>:
toggle quoted message
Show quoted text
Borodoynov
Thank you that looks like a good typical material to use.
My understanding is then that given that I am operating at only 50Hz with just some high frequency transients, that any core losses will be insignificant.
Then I can model in LTSpice the effects of ambient temperature using e.g.:
Hc = 22 at 25C decreasing by 0.12 % per C
Bs = 490m at 25C decreasing by 0.27 % per C
Br = 100m at 25C - Does this have a temperature coefficient?
Thanks and Regards
Henry Kafeman